Triangle bracing system to reduce the vibration level of cooling tower – case study in PT Star Energy Geothermal (Wayang Windu) Ltd – Indonesia

Effendi Tri Bahtiar, Naresworo Nugroho, Dede Hermawan, Wilis Wirawan, Khuschandra

Abstract

Periodical control and measurement revealed that vibration level of motor and gearbox which was supported by Cooling Tower Unit 1 at PT Star Energy Geothermal (Wayang Windu) Ltd was significantly increasing since 2013. The vibration was not caused by machinery component failure, but induced by resonance of process flow. Decreasing stiffness of cooling tower structure was suspected causing the increasing vibration level. The physical, chemical, and mechanical properties of wood was deteriorated. The residual strength of the wood had been measured and the data was used to perform dynamic structural analysis on the cooling tower. Several scenarios of structure modification were modelled and drawn, and the best one which the most effectively reducing the vibration level among others was constructed in the field. Triangle inner structure was chosen and applied to modify the cooling tower structure to achieve stiffer and more rigid structure. The vibration level before and after structure modification were measured, and it was proved that the vibration level was significantly reduced after structure modification. Furthermore the cooling tower was not in zone D (danger) anymore and the vibration level was accepted according to ISO 10816-3. Keywords: Cooling tower, Dynamic structural analysis, Geothermal power plant, Structural failure, Vibration level
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Solar Energy Systems and Technologies · Wind and Air Flow Studies · Vibration Control and Rheological Fluids

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (13)

Show source-provided references
1. Ozelton · 2006
2. Estimation the remaining service-lifetime of wooden structure of geothermal cooling tower10.1016/j.cscm.2017.01.001 ↗
3. Wood deterioration of cooling tower structure at geothermal powerplant10.3923/ajaps.2017.79.87 ↗
4. Evaluation on bracing component of cooling tower in Star Energy Geothermal (Wayang Windu) Ltd and estimation for its remaining service-life time
5. [FPL] Forest Products Laboratory · 2009
6. Serviceability-based damping optimization of randomly wind excited high-rise buildings10.1002/tal.1371 ↗
7. Generalized optimal control policy for stochastic optimal control of structures10.1002/stc.483 ↗
8. Nonlinear dynamics and failure wind velocity analysis of urban trees10.12989/was.2016.22.1.089 ↗
9. Geometries and electronic structures of Boron clusters: planar structures and all-Boron fullerenes
10. P4 9 inferring the nuclear properties of vibranium
11. Stability of two-dimensional iron carbides suspended across graphene pores: first-principles particle swarm optimization10.1021/acs.jpcc.5b06555 ↗
12. Behaviour of multistorey RCC structure with different type of bracing system (a software approach)