Effect of grouting quality on flexural behavior of corroded post-tensioned concrete T-beams
Source abstract
Abstract
The durability of post-tensioned concrete (PTC) bridge structures has been greatly threatened by the corrosion of steel strands, especially in the case of insufficient grouting. In this paper, the effect of grouting quality on flexural behavior of corroded post-tensioned concrete (CPTC) beams is experimentally investigated with two groups of T-beams, i.e., five fully grouted beams in Group A and five partially grouted beams in Group B. Results indicate that when the mass loss of steel strands in Group A ranges from 0 % to 10.47 %, the cracking load decreases by 5.8821.57 %, and the ultimate bearing capacity decreases by 5.45–30.45 %. While for Group B, when the mass loss of steel strands ranges from 0 % to 14.26 %, the cracking load decreases by 3.75–25.00 %, and the ultimate bearing capacity decreases by 7.41–44.91 %. It is observed that as the degree of corrosion increases, both cracking load and ultimate bearing capacity of the beam gradually deteriorate, with the flexural capacity of partially grouted beams deteriorating faster. Built on this and with the model of bond reduction coefficient, an analytical method is proposed to predict the flexural capacity of CPTC beams under different grouting conditions. The developed method provides good predictions compared with experimental results of current study and from literature, paving the way for accurate assessment of the flexural bearing capacity of PTC beams with different grouting qualities in corrosive environments.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Hewson N.R. Prestressed concrete bridges: design and construction. Thomas Telford; 2003.
2. Murillo J. Brief history of segmental concrete bridge construction. Segmental Bridges, 2004; XIX (57).
3. Corroded post-tensioned beams with bonded tendons and wire failure10.1016/j.engstruct.2009.02.043 ↗
4. Mutsuyoshi H. Present situation of durability of post-tensioned PC bridges in Japan. In: Proceedings of workshop on durability of post-tensioning tendons, fib, Belgium, 2001. P. 75–88.
5. Pitting corrosion model for partial prestressed concrete (PC) structures in a chloride environment10.12962/j20882033.v20i3.109 ↗
6. Failure by corrosion in PC bridges: a case history of a viaduct in Italy10.1108/IJSI-09-2014-0046 ↗
7. Ma H.N., Au F.K., Mickleborough N., Lim E.H., Chan K.Y., Chung P.H. Investigation report on prestressing tendon failure incident at concrete viaduct of Shenzhen Bay Bridge-Hong Kong Section. Hong Kong: Highways Department; 2019.
8. Fang H.M. Impact study of grouting defects on the mechanical property of prestressed concrete beam. Thesis (Ph.D). Wuhan: Huazhong University of Science and Technology, 2017. (in Chinese).
9. Influence of grouting condition on crack and load-carrying capacity of post-tensioned concrete beam due to chloride-induced corrosion10.1016/j.conbuildmat.2005.10.004 ↗
10. Chloride-induced corrosion in insufficiently grouted posttensioned concrete beams10.1061/(ASCE)0899-1561(2008)20:1(85) ↗
11. Effect of insufficient grouting and strand corrosion on flexural behavior of PC beams10.1016/j.conbuildmat.2013.11.069 ↗
12. Stress at ultimate in unbonded post-tensioning tendons: part 1-evaluation of the state-of-the-art
13. Stress at ultimate in unbonded post-tensioning tendons: part 2- proposed methodology
14. Tensile and fatigue behavior of corroded rebars10.1016/j.conbuildmat.2012.02.071 ↗
15. Li · 2021
16. Corrosion-induced bond strength degradation in reinforced concrete—analytical and empirical models10.1016/j.nucengdes.2007.01.010 ↗
17. Effects of corrosion on bond behavior between steel strand and concrete10.1016/j.conbuildmat.2012.08.008 ↗
18. A new empirical model for residual flexural capacity of corroded post-tensioned prestressed concrete beams10.1016/j.istruc.2021.10.005 ↗
19. GB 50010-2020 · 2020
20. A new empirical model for flexural stiffness of corroded post-tensioned concrete beams10.1016/j.engstruct.2023.116860 ↗
21. Flexural behavior of corrosion-damaged prestressed concrete beams10.1016/j.engstruct.2022.114985 ↗
22. Effect of stress corrosion cracking on stress–strain response of steel wires used in prestressed concrete beams10.1016/j.corsci.2009.03.033 ↗
23. Corrosion-induced flexural behavior degradation of locally ungrouted post-tensioned concrete beams10.1016/j.conbuildmat.2016.12.140 ↗
24. Flexural behavior of bonded post-tensioned concrete beams under strand corrosion10.1016/j.nucengdes.2017.01.004 ↗
25. An empirical model for the shear strength of corroded reinforced concrete beam10.1016/j.conbuildmat.2018.08.123 ↗
26. Relation between the loss coeffcient of the corroded rebar's cross-section in concrete and that of its weight