Small-scale testing of air barrier systems adhered to sheathing boards under in-plane cyclic loading simulating a seismic event
Source abstract
Abstract
Envelope air leakage is a large contributor of energy loss in modern high-performance construction. Building enclosure designers along with the building science community are emphasizing the importance of incorporating air barrier products in the envelope design. Furthermore, regulators are reassessing the allowable air leakage limits prescribed in local codes, to reduce unintentional infiltration. Although voluntary, Passive House building standards inform methods and targets for achieving minimal air leakage values to meet certification. Commercial air barrier products often satisfy the airtightness requirements during and immediately following construction. However, seismic events could potentially damage the air barrier product and compromise the envelope’s air tightness. This paper presents the findings of an experimental program conducted to test commercially available air barrier products under in plane cyclic loading. A cyclic loading profile was designed to simulate a seismic event. Selected air barrier products were adhered to small-scale sheathing panels and tested after curing. Multiple combinations of sheathing board material and air barrier tapes were tested. The tested sample groups represent the most common air barrier systems used in the industry, incorporating 3 M Construction Seaming Tape, Siga Wigluv 60, Prosoco R-Guard Joint and Seam Filler, and Zip System Tape. The failure load and failure displacement were recorded for each test, along with the corresponding failure mode. The results of the experimental program suggest that 0.5-inches [1.27 cm] of in plane vertical displacement could completely compromise the air barrier layer due to the delamination or tear of the air barrier sealant. • The Air Barrier Cyclic Testing Protocol was developed to test air barrier systems. • Seismic displacements may compromise the building’s air tightness. • Not all air barrier tapes exhibit the same behavior when subjected to relative displacements. • Liquid applied membranes perform differently than pressure applied tapes under relative displacements.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Analysis of Composite Materials · Wind and Air Flow Studies · Masonry and Concrete Structural Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Abdelwahab, K., Gracie-Griffin, C., Memari, A., & Iulo, L. (2022). small-scale testing of air barrier systems adhered on sheathing panels under in-plane relative displacement simulating seismic effect. 6th Residential Building Design & Construction Conference (pp. 372–781). Pennsylvania: Pennsylvania Housing Research Center.
2. Simulating Mode 1 Fatigue Crack Growth Propagation in Adehesively-Bonded Composite Joints
3. 2004
4. 2005
5. 2018
6. Da Silva, L.F., & Campilho, R.D. (2012). Advances in Numerical Modelling of Adhesive Joints. Springer Briefs in Applied Sciences and Technology Computational Mechanics.10.1007/978-3-642-23608-2_1 ↗
7. Eva B. Moller, T.V. (2020). Testing Joints of Air and Vapour Barriers, Do We Use Relevant Testing Methods? XV International Conference on Durability of Building Materials and Components DBMC.10.23967/dbmc.2020.135 ↗
8. Long term performance of Passive House buildings10.1007/s12053-020-09913-0 ↗
9. Experimental analysis of airtightness performance in high-rise residential buildings for improved code-compliant simulations10.1016/j.enbuild.2022.111980 ↗
10. Vapour resistance of wind barrier tape: Laboratory measurements and hygrothermal performance implications
11. Jones, D., Brown, B., Thonmpson, T., Finch, Graham,. Building Enclosure Airtightness Testing in Washington State - Lessons Learned About Air Barrier Systems and Large Building Testing Procedures. ASHRAE 2014 Annual Conference, Seattle WA.
12. Air Leakage Levels in Timber Frame Building Envelope Joints10.1016/j.buildenv.2017.02.011 ↗
13. Laboratory Investigation on the Durability of Taped Joints in Exterior Air Barrier Applications
14. A Cohesive Model for Fatigue Failure of Polymers10.1016/j.engfracmech.2004.06.005 ↗
15. Malin Sletnes, S.F. (2020). Performance and Durability of Adhesive Tapes for Building Applications. From Product Documentation to Scientific Knowledge (and Back Again). XV International Conference on Durability of Building Materials and Components DBMC.10.23967/dbmc.2020.106 ↗
16. Ali M. Memari, L. D (2019). Study of Vulnerability of Air Barrier Membranes and Sealant Joint Tapes Applied over Wood Sheathing Panel Joints Due to Racking Movement in Passive House Designed Residential Buildings. 29(1), 10–17.
17. A Procedure for the Simulation of Faitigue Crack Growth in Adhesively Bonded Joints Based on a Cohesive Zone Model and Various Mixed-Mode Propagation Criteria10.1016/j.engfracmech.2012.04.003 ↗
18. Max H. Sherman, D. J (1998). Airtightness of US Dwellings. 104 (2).
19. Estimating infiltration losses for in-situ measurements of the building envelope thermal performance
20. Thiede · 2013 · 837
21. Van Linden, S., Maroy, K., Steeman, M., & Van Den Bossche, N. (2017). Tape as a Means to Ensure Air- and Watertightness of Building Joints: Experimental Assessment. 14th International Conference on Durability of Building Materials and Components.