Concrete contribution to shear resistance of GFRP-RC beams under fire exposure
Source abstract
Abstract
Currently, there is a lack of research on how fire affects the shear capacity of reinforced concrete (RC) beams reinforced with glass fiber-reinforced polymer (GLASS-F.R.P.) bars. This study examines the shear performance of beams reinforced with GLASS-F.R.P. bars when exposed to fire. Twelve RC beam specimens were fabricated for this purpose, exposed to fire, and then subjected to four-point bending until failure. The specimens had a total span of 1700 mm and a concrete cross-section measuring 150 mm wide and 300 mm deep. The parameters were the ratio of reinforcements and the duration of the firing. The test findings indicate that the concrete's ability to resist shear forces is affected by both the ratio of reinforcement and the length of time it is exposed to fire. Increasing the amount of flexural reinforcement specifically enhances the shear capability. On the other hand, increasing the amount of time that something is subjected to fire decreases its ability to withstand force. It has been noted that the shear design equations from ACI 440.11–22 (ACI-22) and ECP 208–05 (ECP-05) tend to be conservative for elements regardless of fire exposure. In contrast, the shear design methodology described in CSA S806–12 (CSA-12) stands out as the most accurate approach for predicting shear capacity.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. Performance of lightweight self-consolidating concrete beams reinforced with glass fiber-reinforced polymer bars without stirrups under shear
2. Bond-dependent coefficient kb for new-generation GFRP bars10.1061/JCCOF2.CCENG-4341 ↗
3. ACI (American Concrete Institute) · 2015
4. ACI (American Concrete Institute) · 2022
5. Canadian Standards Association (CSA). (2012) – Re-approved in 2017 –. “Design and construction of building components with fiber reinforced polymers.” CSA-S806-12 (CSA-12). Rexdale, Ontario, Canada.
6. Egyptian Code for the Use of Fiber Reinforced Polymers in the Construction Field. ECP-208-05. (ECP-05). Housing and Building National Research Center, Cairo, Egypt.
7. ACI (American Concrete Institute) · 1989
8. Evaluation of self-compacting concrete columns reinforced with steel and F.R.P. bars with different strengthening techniques
9. Assessment of high thermal effects on carbon nanotube (cnt)-reinforced concrete10.1038/s41598-018-29663-5 ↗
10. Effect of fire on F.R.P. reinforced concrete members10.1016/S0263-8223(02)00045-4 ↗
11. GFRP-reinforced concrete slabs: fire resistance and design efficiency10.1061/(ASCE)CC.1943-5614.0000937 ↗
12. Behaviour of concrete beams reinforced using basalt and steel bars under fire exposure10.1016/j.engstruct.2021.112251 ↗
13. Data-driven modeling of mechanical properties of fiber-reinforced concrete: a critical review10.1007/s11831-023-10043-w ↗
14. Machine-learning methods for estimating performance of structural concrete members reinforced with fiber-reinforced polymers
15. Machine-learning methods for estimating compressive strength of high-performance alkali-activated concrete10.1016/j.engappai.2024.109053 ↗
16. ASTM C39/C39M-18 · 2018
17. British Standards Institution (BSI). (1985). Structural use of concrete: Code of practice for design and construction. BS 8110-85, London.
18. Japan Society of Civil Engineers (JSCE). (1997). Recommendations for design and construction of concrete structures using continuous fiber reinforced materials. Research committee on continuous fiber reinforced materials, A. Machida, ed., Tokyo.
19. Proposed shear design method for FRP-reinforced concrete members without stirrups
20. Shear tests of FRP-reinforced concrete beams without stirrups