journal article·2024-12Open access

Mechanical performance and failure mode judgment criteria of grouted sleeve connectors considering large deformation and grouting compactness

Chen Wu, Xiaofei Xiao, Shenglan Ma, Chao Yang

Abstract

Three groups of 36 grouted sleeve connectors (GSCs) with different grouting compactness were experimentally investigated under monotonic tension and large-deformation reciprocating tension-compression. The experimental results showed that the failure mode contained the tensile fracture of the steel bar (Failure Mode I) and bond-slip failure (Failure Mode II). The yield strength, ultimate strength, and elongation of GSCs gradually decreased, while the residual deformation increased as the grouting compactness decreased. The average ultimate strength of GSCs with 90 % grouting compactness was 561.61 MPa, a 124.46 % enhancement over that of GSCs with 60 % grouting compactness. The loading method mainly affected the residual deformation of GSCs, which increased with the cycle number of large-deformation reciprocating loadings at consistent grouting compactness. Subsequently, based on the effects of the grouting compactness and large deformation on the mechanical performance of GSCs, this study combined the critical grouting compactness and f u / f sy to judge the failure mode of GSCs with steel bar diameters of 20 cm, which were determined to be 90 % and 1.4, respectively. These findings provide a foundation for designing assembled structural connections and ensuring the safety of assembled structures. • Novel double-control method proposed for grouting compactness simulation. • Discussed effects of grouting compactness and loading conditions. • Confirmed critical grouting compactness and f u / f sy . • Criteria considering large deformation proposed for failure mode judgment of GSCs.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Mechanical stress and fatigue analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Experimental investigation on connection performance of fully-grouted sleeve connectors with various grouting defects10.1016/j.conbuildmat.2022.126981 ↗
2. Study on tensile properties of semi grouted sleeve connectors after high temperature10.1016/j.conbuildmat.2021.124088 ↗
3. Research on pseudo-static cyclic tests of precast concrete shear walls with vertical rebar lapping in grout-filled constrained hole10.1016/j.engstruct.2019.03.069 ↗
4. Quasi-static test and strut-and-tie modeling of precast concrete shear walls with grouted lap-spliced connections10.1016/j.conbuildmat.2017.05.183 ↗
5. Research on the out-of-plane mechanical performance of double-face superposed shear walls with different horizontal connections
6. Experimental analysis on the out-of-plane structural performance of single-face superposed shear walls with different horizontal connections
7. New precast prestressed system saves money in Hawaii hotel
8. Tensile strength of the grout-filled head-splice-sleeve10.1016/j.conbuildmat.2016.07.028 ↗
9. Seismic performance of precast column connected with grouted sleeve connectors
10. Tensile behavior of grouted sleeve couplers connecting steel bars with transition splicing10.1007/s42107-021-00361-4 ↗
11. Mechanical performance of precast RC columns with grouted sleeve connections10.1016/j.engstruct.2021.113654 ↗
12. Mechanical behaviour of grouted sleeve splice under uniaxial tensile loading10.1016/j.engstruct.2019.02.033 ↗
13. Connection performance of restrained deformed grouted sleeve splice10.1177/1369433217719987 ↗
14. On the early-age bond-slip behavior of an eccentric bar embedded in a grouted sleeve10.1016/j.engstruct.2019.04.020 ↗
15. Experimental investigation on the failure modes of grouted sleeve connections under thermal and mechanical loads10.1016/j.engfailanal.2019.104246 ↗
16. Mechanical behaviours of heat-damaged grouted sleeve connections10.1016/j.firesaf.2021.103345 ↗
17. Evaluation of common defects of grouted sleeve connectors
18. Study of effects of sleeve grouting defects on the seismic performance of precast concrete shear walls10.1016/j.engstruct.2020.111833 ↗
19. Effect of connection deficiency on seismic performance of precast concrete shear wall-frame structures10.1142/S1793431119400050 ↗
20. Experimental bond behavior of deformed rebars in half-grouted sleeve connections with insufficient grouting defect10.1016/j.conbuildmat.2018.07.050 ↗
21. Experimental study on post-fire performance of half grouted sleeve connection with construction defect10.1016/j.conbuildmat.2020.118165 ↗
22. Mechanical performance for defective and repaired grouted sleeve connections under uniaxial and cyclic loadings10.1016/j.conbuildmat.2019.117233 ↗
23. Experimental study on influence of connection defects on joint strength of half-grouted sleeve splicing of rebar
24. Study of mechanical properties of grouting defective sleeve10.1016/j.istruc.2023.01.035 ↗
25. Tensile behavior of half grouted sleeve connections: experimental study and analytical modeling10.1016/j.conbuildmat.2017.06.154 ↗
26. An overview of studies on grouted sleeve connections
27. Effects of grout sleeve defects and their repair on the seismic performance of precast concrete frame structures10.1016/j.engstruct.2021.112619 ↗
28. Dall'Asta A. Splice methods used for reinforcement steel bars: a state-of-the-art review10.1016/j.conbuildmat.2021.126198 ↗
29. Prediction and interpretation of failure modes of grouted sleeve by combined knowledge-driven and datadriven methodology
30. Tensile capacity of grouted splice sleeves10.1016/j.engstruct.2015.12.023 ↗
31. Ministry of Housing and Urban-Rural Development of the People's Republic of China. The grouting coupler for rebars splicing. JG/T 398-2012, Standards Press of China, Beijing; 2012. [In Chinese].
32. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China. Metallic materials-tensile testing-part 1: Method of test at room temperature. GB/T 228.1-2010, Standards Press of China, Beijing; 2010. [In Chinese].
33. Ministry of Housing and Urban-Rural Development of the People's Republic of China. Cementitious grout for coupler of rebar splicing. JG/T 408-2013, Standards Press of China, Beijing; 2013. [In Chinese].