journal article·2025-07Open access

Study on progressive collapse mechanism of RC frame structures corroded by chloride

Chao Bao, Huxiang Wang, Huan Long, Ibrahim M.H. Alshaikh, Ziyad Al-Gaboby, Xiaotong Ma

Abstract

An excessive failure mechanism describes the progressive collapse of reinforced concrete (RC) structures, where localized initial damage from abnormal loading cases can lead to either the collapse of a significant component or the entire structure. RC structures in coastal or saline environments face long-term degradation due to environmental corrosive agents, with steel corrosion, which is induced by chloride ingress being a major cause. This study investigates the effect of full-beam corrosion on the progressive collapse behavior of RC frame structures. Therefore, quasi-static loading tests were carried out to examine two 1/3-scale RC substructure specimens. For comparison purposes, one specimen serves as a control specimen and another specimen has been exposed to corrosion treatment using electrochemical methods. The results indicated that the structure’s resistance mechanism remained unchanged after steel corrosion, but the corroded structure entered the catenary action mechanism earlier. Corrosion weakens the enhancement effects of compression arching and catenary action on the structural resistance, and the yield load, first peak load, and ultimate load of the specimen have all decreased by 4.8%, 3.2%, and 43.8%, respectively. Based on the quasi-static test results, dynamic responses of the two types of specimens were obtained, and collapse resistance assessments were conducted, specimen F14-0 still retained 11% residual capacity against collapse, while the corroded specimen recorded 6.2% only, a decrease of nearly 44%.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Response to Dynamic Loads · Concrete Corrosion and Durability · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Minimum design loads and associated criteria for buildings and other structures
2. Progressive collapse: past, present, future and beyond10.1016/j.istruc.2024.106131 ↗
3. A conceptual note on the definition of initial failure in progressive collapse scenarios10.1016/j.istruc.2024.105921 ↗
4. Experimental investigation of the progressive collapse of reinforced concrete structures: an overview10.1016/j.istruc.2020.03.018 ↗
5. Precast RC structures’ progressive collapse resistance: current knowledge and future requirements10.1016/j.istruc.2021.12.086 ↗
6. A preliminary analysis and discussion of the condominium building collapse in surfside, Florida, US, June 24, 202110.1007/s11709-021-0766-0 ↗
7. BS8110 · 1997
8. EN1991-1-7 · 2006
9. DoD · 2016
10. GSA · 2003
11. CECS. Code for anti-collapse design of building structures. Beijing: China Association for Engineering Construction Standardization, 2021. (In Chinese).
12. Assessing failure of corroded RC beams under mechanical loads by DIC-AE data analysis10.1016/j.conbuildmat.2024.138736 ↗
13. Flexural reliability of corroded RC beams strengthened with CFRP sheets considering longitudinal corrosion non-uniformity of steel bars
14. Residual flexural capacity of corroded reinforced concrete beams after exposure to fire10.1016/j.istruc.2024.105991 ↗
15. Speculation on the role of sea-level rise in the tragic collapse of the Surfside condominium (Miami Beach, Florida USA) was a bellwether moment for coastal zone management practitioners10.1016/j.ocecoaman.2021.105968 ↗
16. Progressive collapse resistance mechanism of RC frame structure considering reinforcement corrosion
17. Chen J. Analysis of progressive collapse performance of RC structures considering steel corrosion. Harbin: Harbin Institute of Technology, 2020. (In Chinese).
18. Wei T.Y. Study on load carrying mechanism of existing RC frames including corrosion effects to resist progressive collapse. Guangxi University, 2018. (In Chinese).
19. Effects of corrosion on compressive arch action and catenary action of RC frames to resist progressive collapse based on numerical analysis10.3390/ma14102662 ↗
20. Time-dependent reliability-based redundancy assessment of deteriorated RC structures against progressive collapse considering corrosion effect10.1016/j.strusafe.2020.102061 ↗
21. Progressive collapse behavior of aging reinforced concrete structures considering corrosion effects10.1061/(ASCE)CF.1943-5509.0001001 ↗
22. Progressive collapse behavior of RC frames subjected to reinforcement corrosion
23. Effect of steel reinforcement corrosion on progressive collapse resistant of beam-slab structure with interior column failure10.1016/j.engstruct.2024.118257 ↗
24. Study on load resisting mechanism of corroded RC frame structures against progressive collapse
25. China Ministry of Construction · 2015
26. Effect of corrosion on ductility of reinforcing bars10.1680/macr.2005.57.7.407 ↗
27. Investigation of mixed-mode fracture of UHPC using a hybrid digital image correlation and peridynamics approach10.1016/j.optlaseng.2021.106918 ↗
28. Progressive collapse of multi-storey buildings due to sudden column loss-Part Ⅰ: Simplified assessment framework10.1016/j.engstruct.2007.07.011 ↗
29. Progressive collapse of multi-story buildings due to sudden column loss-Part Ⅱ: application10.1016/j.engstruct.2007.08.011 ↗
30. Strengthening and retrofitting of RC flat slabs to mitigate progressive collapse by externally bonded CFRP laminates10.1061/(ASCE)CC.1943-5614.0000352 ↗
31. Research on progressive collapse resistance capacity of composite frame with CFST columns under Corner column removal scenario[J]
32. Experimental study on progressive collapse-resistant behavior of reinforced concrete frame structures