journal article·2022-12Open access

Material enhancements of newly developed stiff type polyurea for retrofitting of concrete structures

Tae-Hee Lee, Jun-Hee Park, Dal-Hun Yang, Jang-Ho Jay Kim, Norhazilan Bin Md. Noor

Abstract

Recently, polyurea (PU) has been receiving great interest from the construction industry as a structural retrofitting and strengthening material due to its simple application of spraying on the structural member surface without creating an epoxy bonding interface. In this study, based on knowledge gained from developing flexible-type PU (FTPU) in preceding studies, stiff-type PU (STPU) is developed by varying the prepolymer/hardener ratio of FTPU. A mechanical property evaluation of STPU is performed through tensile strength, percent elongation, pull-off, and Shore hardness tests. Furthermore, a durability property evaluation of STPU is performed through acid environmental and ultraviolet (UV) exposure tests. In addition, concrete carbonation exposure and freeze–thaw tests are performed for STPU. The experimental results show that STPU has a higher tensile strength and lower elongation percentage than FTPU with excellent mechanical and durability properties. Using the optimal mix proportion of STPU, the surfaces of concrete specimens sprayed with STPU are tested under uniaxial compression loading. The uniaxial test results show that the strengthened concrete specimens have maximum load ratios 1.14–1.20 times those of the non-strengthened concrete specimens. Based on the test results, STPU can be used as a retrofitting and strengthening material for concrete members to resist seismic and extreme loading (e.g., impact, blast).
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Korea Meteorological Administration (KMA), Earthquake, Korea. https://www.weather.go.kr/plus/eqkvol/domesticlist.jsp?startTm=2016–01-01&endTm=2016–1230&startSize=5.0&endSize=5.5&startLat=&endLat=&startLon=&endLon=&lat=&lon=&dist=&keyword=&schOption=T&x=37&y=7, September, 2016.
2. Nam H.W. The Status of Earthquake Occurrence in Korea in 2013. Press Release of Korea Meteorological Administration, Korea, 2014.
3. Behavioral trends of RC beams strengthened with externally bonded FRP10.1061/(ASCE)1090-0268(2001)5:2(102) ↗
4. Cellulose nanocrystals from office paper waste for green mortar: process optimization modeling, characterization, and mechanical properties10.1007/s13369-022-06609-8 ↗
5. Development and testing of cellulose nanocrystal-based concrete
6. Bond–slip models for FRP Sheets/plates bonded to concrete10.1016/j.engstruct.2005.01.014 ↗
7. Numerical evaluation of the retrofit effectiveness for GFRP retrofitted concrete slab subjected to blast pressure10.1016/j.compstruct.2009.10.031 ↗
8. Evaluation of CFRP, GFRP and BFRP material systems for the strengthening of RC slabs10.1177/0731684407084122 ↗
9. Seismic resistance of RC bent caps in elevated mass transit structures10.1193/1.3533471 ↗
10. Strength estimation for FRP wrapped reinforced concrete columns10.12989/scs.2002.2.1.001 ↗
11. Behaviour of FRP wrapped normal strength concrete columns under eccentric loading10.1016/j.compstruct.2005.01.018 ↗
12. Modelling of rectangular RC columns strengthened with FRP10.1016/S0958-9465(02)00017-3 ↗
13. Retrofit of bond-critical regions in circular RC columns: validation of proposed design methods
14. Effect of recycled concrete on the flexural behavior of concrete-filled FRP tubes10.1186/s40069-018-0318-8 ↗
15. Response of Glass Fiber Reinforced Polymer (GFRP)-steel hybrid reinforcing bar in uniaxial tension10.1007/s40069-017-0212-9 ↗
16. Concentrically loaded circular RC columns partially confined with FRP10.1186/s40069-018-0283-2 ↗
17. Development and applicability evaluation of high performance poly-urea for RC construction reinforcement
18. Performance evaluation of RC slab strengthened by stiff type polyurea
19. Evaluation of strengthening performance of stiff type polyurea retrofitted RC slab based on attachment procedure10.4334/JKCI.2011.23.4.511 ↗
20. Kim J.H.J., Yi N.H., Kim S.B., et al. Experiment study on blast loading response of FRP-retrofitted RC slab structures. In: The Second official International Conference of International Institute for FRP in Construction for Asia-Pacific Region, Seoul, Korea, 9 December -11 December 2009, 3(4): 533–538.
21. Lamba · 1998 · 14
22. Physical Test Methods for Vulcanized Rubber
23. KS F 4922: 2007. Polyurea Resin Waterproofing Membrane Coating. Korea Standards Association, Korea.
24. KS M ISO 7619–1: 2011. Rubber, Vulcanized or Thermoplastic-Determination of Indentation Hardness-Part 1: Durometer method (Shore hardness). Korea Standards Association, Korea.
25. KS M ISO 6353–2 (R37): 2012. Reagents for chemical analysis – Part 2: Specifications – First Series [Sulfuric acid]. Korea Standards Association, Korea.
26. KS F 2274: 2002. Recommended Practice for Accelerated Artificial Exposure of Plastics Building Materials. Korea Standards Association, Korea.
27. Kim Y.S., Choi M.I., Kim C.M., et al. A Study of Corona Discharge in Polymer Insulators by Artificial UV Radiation. The Transactions of the Korean Institute of Electrical Engineers 2013; 17(6): 21–30. (In Korea).
28. KS F 2584: 2010. Standard Test Method for Accelerated Carbonation of Concrete. Korea Standards Association, Korea.
29. KS F 2456: 2010. Standard Test Method for Resistance of Concrete to Rapid Freezing and Thawing. Korea Standards Association, Korea.
30. Kim T.K. Performance Based Evaluation of Concrete for Strength and Durability Considering Curing under Extreme Conditions Produced by Climate Change. PhD thesis, Yonsei University, Korea, 2016.
31. Comparative carbon emission assessments of recycled and natural aggregate concrete: Environmental influence of cement content10.1016/j.gsf.2021.101235 ↗
32. Using artificial neural network and non‐destructive test for crack detection in concrete surrounding the embedded steel reinforcement10.1002/suco.202000767 ↗
33. Latin hypercube sensitivity analysis and non-destructive test to evaluate the pull-out strength of steel anchor bolts embedded in concrete10.1016/j.conbuildmat.2021.123256 ↗