journal article·2025-12Open access

Strengthening of RC flat slab-column connections against punching shear using engineered cementitious composites (ECC) with PE and hybrid steel/PE fibres: An experimental and theoretical study

Yanli Su, Chang Wu, Mingwen Xu, Xinru Wang, Chenhua Jin, Mingzhong Zhang

Abstract

Engineered cementitious composite (ECC) exhibits excellent tensile properties and strain-hardening behaviour, which has proven to be a potential material for addressing the brittle failure mode occurred in reinforced concrete (RC) flat systems. This study employs a systematic experimental and theoretical approach to investigate the improvement of punching shear behaviour in slab-column connections through the incorporation of ECC. Eight connections were designed accounting for the effects of ECC zone area, steel reinforcement ratio, and fibre type and dosage in ECC, which were subjected to concentric loading to investigate the load-bearing capacity, crack patterns, deformation characteristics and failure mechanisms. Experimental results indicate that all specimens ultimately failed through punching shear, while ECC-enhanced connections exhibited significantly improved ductility compared to conventional RC counterparts. ECC increased the first crack load and load-bearing capacity of connections by 18.58–33.31 % and 34.15–37.76 %, respectively. Yielding of the reinforcing bars was observed in all specimens, with higher reinforcement ratios and fibre dosages enhancing the yield load. Increasing the polyethylene (PE) fibre dosage in ECC from 1.0 % to 2.0 % led to a rise of the load capacity, deformation resistance and yield load. ECC with hybrid steel (0.5 %) and PE (1.5 %) fibres enhanced the structural stiffness but had a negligible effect on punching shear capacity when compared to ECC containing 2 % PE fibres. Punching shear failure surfaces consistently formed outside the ECC zone, effectively expanding the base perimeter of the shear cone and increasing the critical punching shear crack angle, which was considered to determine the critical section coefficient k . Applying the modified k to GB50010–2010 and DIN 1045–1 provisions gave accurate predictions of the punching shear strength for ECC-enhanced connections featuring critical sections of the punching shear cones outside the ECC zone.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. On punching shear strength of steel fiber-reinforced concrete slabs-on-ground
2. António VG. Numerical simulation of the punching shear behaviour of self-compacting fibre reinforced flat slabs10.1016/j.conbuildmat.2014.10.003 ↗
3. Punching shear of RC flat slabs – review of analytical models for new and strengthening of existing slabs10.1016/j.engstruct.2013.02.014 ↗
4. Effect of premature loading on punching resistance of reinforced concrete flat slabs
5. Post-punching failure mechanism and resistance of flat plate-column joints with in-plane constraints10.1016/j.engfailanal.2022.106360 ↗
6. Case study on strengthening methods for progressive collapse resistance of RC flat slab buildings10.1016/j.istruc.2020.12.049 ↗
7. Progressive collapse behaviour of reinforced concrete flat slab buildings subject to column failures in different storeys10.1016/j.matpr.2020.07.692 ↗
8. Progressive collapse performance of RC flat plate frame structures10.1061/(ASCE)ST.1943-541X.0000963 ↗
9. Experimental investigation on failure modes of RECC slab-column connections under concentric gravity loading10.1016/j.engstruct.2020.111559 ↗
10. Strengthening of slab-column connections using ultra high-performance fiber concrete
11. Using ultra-high performance fiber reinforced concrete in improvement shear strength of reinforced concrete beams
12. Post-cracking punching shear behavior of concrete flat slabs partially reinforced with full-depth UHPC: experiment and mechanical model10.1016/j.engstruct.2022.115313 ↗
13. Punching shear behavior of ultra-high-performance fiber-reinforced concrete and normal strength concrete composite flat slabs10.1016/j.engstruct.2024.119123 ↗
14. Steady-state and multiple cracking of short random fiber composites10.1061/(ASCE)0733-9399(1992)118:11(2246) ↗
15. Micromechanics of crack bridging in fiber reinforced concrete10.1007/BF02472808 ↗
16. Engineered/strain-hardening cementitious composites (ECC/SHCC) with an ultra-high compressive strength over 210 MPa10.1016/j.coco.2021.100775 ↗
17. Ultra-high-strength engineered/strain-hardening cementitious composites (ECC/SHCC): material design and effect of fiber hybridization10.1016/j.cemconcomp.2022.104464 ↗
18. Flexural behavior of GFRP reinforced concrete beams with CFRP grid-reinforced ECC stay-in-place formworks10.1016/j.compstruct.2021.114653 ↗
19. Reinforced high-strength engineered cementitious composite (ECC) columns under eccentric compression: experiment and theoretical model
20. Flexural behaviors of GFRP-reinforced engineered cementitious composite (ECC)-concrete composite beams
21. Experimental study and analytical model of masonry columns confined with fiber grid-reinforced ECC under cyclic compression load10.1016/j.engstruct.2024.119560 ↗
22. Experimental study on seismic performance of RC beam- CFST column joint combination using ECC10.1016/j.engstruct.2024.118188 ↗
23. Ultimate performance of two-way reinforced concrete flat slabs enhanced by SHCC drop panels mitigating punching failure
24. Flexural capacity of RC beams reinforced with ECC layer and steel plate
25. Experimental investigation of flexural and punching behavior for plain PE-ECC slabs with different fiber volume fractions and span-depth ratios10.1016/j.conbuildmat.2024.137502 ↗
26. Comparative study of reinforced-engineered cementitious composites and reinforced-concrete slab–column connections under a vertical monotonic load10.1016/j.engstruct.2021.112740 ↗
27. Experimental investigation on failure modes of RECC slab-column connections under concentric gravity loading10.1016/j.engstruct.2020.111559 ↗
28. Punching shear behavior and strength prediction of UHTCC-enhanced RC slab-column joints10.1016/j.engstruct.2023.116162 ↗
29. Numerical and analytical investigations on punching shear performance of UHTCC-enhanced RC slab-column joints
30. Punching shear behavior of flat slabs composed of normal concrete and ECC under the unbalanced moment
31. Punching shear tests and design of UHTCC-enhanced RC slab–column joints with shear reinforcements10.1680/jmacr.23.00362 ↗
32. Punching shear performance of reinforced concrete slab-to-steel column connections incorporating ECC and UHPECC10.1016/j.engstruct.2024.119145 ↗
33. Study on punching shear resistance of slab-column connections with partial ECC replacement
34. Punching shear behavior of RC slab-column connections enhanced with ECC in core area10.1016/j.istruc.2025.108567 ↗
35. GB 50010-2010, Code for design of concrete structures. Beijing: China Architecture & Building Press, Beijing, 2015.
36. JC/T 2416-2018, Test method for mechanical properties of high ductility fiber reinforced cement matrix composites. China Building Materials Industry Press, Beijing, 2018.
37. ACI Committee, 2019. ACI 318–19: Building Code Requirements for Structural Concrete and Commentary. American Concrete Institute: Farmington Hills, MI, USA.
38. FIB-federation internationale du beton, 2013. fib model code for concrete structures 2010. John Wiley & Sons.10.1002/9783433604090 ↗
39. DIN 1045-1, 2008. German Institute for Standardization Concrete, Reinforced and Prestressed Concrete Structures-Part 1: Design and Construction.
40. CEN (European Committee for Standardization), 2004. Design of concrete structures-Part 1-1: General rules and rules for buildings. Eurocode 2.
41. Yield-line theory and limit analysis of plates and slabs10.1680/macr.1970.22.71.99 ↗