journal article·2023-07Open access

Seismic retrofitting of a deteriorated RC building

Mohamed Selim, Yasser E. Ibrahim, Mohamed Emara

Abstract

Numerous existing reinforced concrete (RC) buildings don’t fulfill current seismic code provisions as they haven’t been designed to satisfy these provisions. Also, due to many environmental factors, structural members such as columns, beams, and slabs are exposed to severe deterioration leading to high-risk levels. In this research, the performance of an existing seven-floor reinforced concrete building in Zagazig city, Egypt, constructed about 50 years ago, without considering the seismic requirements prescribed in the current Egyptian code (ECP-2012) is studied. The studied building suffers severe deterioration in its main structural elements, especially the basement floor slab. SAP2000 software is utilized to evaluate the structural behavior of the building under vertical loads (dead and live loads). The model failed to fulfill the ECP-2012 requirements under the applied loads. After building investigation, a retrofitting technique was proposed through providing the building with new grid beams at the basement floor level as well as replacing the existing basement floor slab with a new one. Moreover, RC jackets were provided to all basement floor columns. Through response spectrum analysis (RSA), the performance of the building with the newly proposed technique was assessed considering a peak ground acceleration equals 0.15 g (seismic zone 3). The model showed a significant enhancement in its response that fulfilled the ECP requirements concerning both strength and serviceability. Utilizing SeismoStruct software, the horizontal capacity of the model was inspected through the pushover analysis to check the efficiency of the proposed retrofitting technique. The model showed acceptable capacity in its two main directions.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Seismic Performance and Analysis · Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Raza, S.; Khan, M.K.I.; Menegon, S.J.; Tsang, H.-H.; Wilson, J.L. Strengthening and Repair of Reinforced Concrete Columns by Jacketing: State-of-the-Art Review. Sustain. 2019, Vol. 11, Page 3208 2019, 11, 3208, doi:10.3390/SU11113208.10.3390/su11113208 ↗
2. Enhancement of circular RC columns using steel mesh as internal or external confinement under the influence of axial compression loading10.3221/IGF-ESIS.58.07 ↗
3. Performance of reinforced concrete buildings during the May 1, 2003 bingöl earthquake in Turkey10.1016/j.engstruct.2004.02.005 ↗
4. Drift capacity of rectangular reinforced concrete columns with low lateral confinement and high-axial load10.1061/(ASCE)0733-9445(2003)129:6(733) ↗
5. A novel seismic strengthening method of rc columns confined by direct fastening steel plates10.1016/j.engstruct.2020.110838 ↗
6. Concrete jacket construction detail effectiveness when strengthening RC columns10.1016/j.conbuildmat.2006.08.019 ↗
7. Seismic retroftting of RC columns with RC jackets and wing walls with different structural details
8. Cyclic loading tests of RC columns strengthened with high ductile fiber reinforced concrete jacket10.1016/j.conbuildmat.2017.07.175 ↗
9. Strengthening of flexure-dominate RC Columns with ECC jackets: experiment and analysis10.1016/j.engstruct.2020.111809 ↗
10. Behavior of partially strengthened reinforced concrete columns from two or three sides of the perimeter
11. Reinforced concrete jacketing--interface influence on cyclic loading response
12. Cyclic responses of reinforced concrete composite columns strengthened in the plastic hinge region by HPFRC mortar10.1016/j.compstruct.2012.01.025 ↗
13. Seismic behavior of corrosion-damaged RC columns strengthened with TRC under a Chloride environment10.1016/j.conbuildmat.2019.01.009 ↗
14. Behavior of ECC columns confined using steel wire mesh under axial loading
15. Compressive behaviour of concrete column confined with basalt textile reinforced ECC10.1016/j.engstruct.2021.112651 ↗
16. Rehabilitation of shear critical concrete columns by use of rectangular steel jackets
17. Seismic retrofit schemes for RC structures and local-global consequences10.1002/pse.208 ↗
18. RC columns strengthened by steel caging: cyclic loading tests on beam-column joints with non-ductile details10.1016/j.conbuildmat.2021.124105 ↗
19. Axial compressive behaviour of RC columns strengthened with rectangular steel tube and cementitious grout jackets10.1016/j.istruc.2020.10.063 ↗
20. Structural performance of RC columns retrofitted with steel-reinforced grout jackets under combined axial and lateral loading10.1016/j.engstruct.2021.112946 ↗
21. Performance evaluation of structures with reinforced concrete columns retrofitted with steel jacketing
22. Behavior of RC columns and those strengthened with FRP composite under an innovative reversing cyclic eccentric axial loading10.1016/j.engstruct.2021.112438 ↗
23. Compression behavior of FRP-strengthened rc square columns of varying slenderness ratios under eccentric loading
24. Experimental study and numerical analysis on seismic performance of FRP confined high-strength rectangular concrete-filled steel tube columns10.1016/j.tws.2021.107560 ↗
25. Concentric compressive behavior of hybrid concrete–stainless steel double-skin tubular columns incorporating high performance concretes
26. The effect of CFRP-shear strengthening on existing circular RC columns under impact loads10.1016/j.conbuildmat.2021.124185 ↗
27. Experimental investigation on short concrete columns laterally strengthened with ferrocement and CFRP
28. NSM rebar and CFRP laminate strengthening for RC columns subjected to cyclic loading10.1016/j.conbuildmat.2016.04.120 ↗
29. Behavior of NSM CFRP reinforced concrete columns: experimental and analytical work
30. Time-dependent behavior of reinforced concrete columns subjected to high sustained loads10.1061/(ASCE)ST.1943-541X.0003462 ↗