Effects of fastener type, end distance, layer arrangement, and panel strength direction on lateral resistance of single shear lap joints in cross-laminated timber (CLT)
Source abstract
Abstract
This research investigated the effects of the fastener type, end distance, layer arrangement, and panel strength direction on the lateral resistance of nailed and screwed single shear lap joints in CLT panels. Three-ply CLT panels were made out of poplar wood (Populus alba) with two layer arrangements: 0/90/0° and 0/45/0°. The lateral resistance of nine types of fasteners with end distances of one, two, and three centimeters in two major and minor strength directions of CLT panels was measured by Instron (model 4486) testing machine. The major axis of CLT panels with the 0/45/0° arrangement showed the highest lateral resistance; however, its minor axis showed the lowest one. Among fasteners, Lag screws (10 mm) had the highest lateral resistance, while steel nails had the weakest. In all CLT samples, by changing the fastener type, end distance, layer arrangement, and panel strength direction, the lateral resistance changed 155.8%, 72.1%, 3.3%, and 19.6%, respectively. Furthermore, changing the failure mode of the fasteners from Im to IV, and CLT members from shear to bearing mode due to the increase in the end distance enhanced lateral resistance, leading to ductile behavior. The NDS, Eurocode 5, and CSA 086 theoretical models were applied to predict the yield lateral loads of the connections. The results showed that Eurocode 5, and CSA 086 better predicted the lateral load of connections with MAPE of 33.8 and 34.24%.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Tree Root and Stability Studies · Bamboo properties and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Flexural performance of cross-laminated timber constructed from fibre-managed plantation eucalyptus10.1016/j.conbuildmat.2019.03.010 ↗
2. S. Gagnon, C. Pirvu, CLT handbook: Cross-laminated timber, FPInnovations2011.
3. Hygrothermal performance of cross-laminated timber wall assemblies: A stochastic approach10.1016/j.buildenv.2015.11.034 ↗
4. C. Handbook, Cross Laminated Timber; FP Innovation Special Publication SP-529E; US Edition: St, Jean Pointe-Claire, QC, Canada (2013).
5. Structural performance of laminated-bamboo lumber nailed connection
6. Cross laminated timber (CLT): overview and development10.1007/s00107-015-0999-5 ↗
7. A comprehensive taxonomy for structure and material deficiencies, preventions and remedies of timber bridges
8. Cross-laminated timber shear connections with double-angled self-tapping screw assemblies10.1061/(ASCE)ST.1943-541X.0001572 ↗
9. Seismic analysis of cross-laminated multistory timber buildings using code-prescribed methods: Influence of panel size, connection ductility, and schematization10.1061/(ASCE)ST.1943-541X.0001344 ↗
10. Lateral and withdrawal capacity of fasteners on hybrid cross-laminated timber panels10.1061/(ASCE)MT.1943-5533.0002432 ↗
11. Experimental evaluation of angle bracket connections in CLT structures under in-and out-of-plane lateral loading10.1016/j.engstruct.2021.112787 ↗
12. W. Muñoz, M. Mohammad, S. Gagnon, Lateral and withdrawal resistance of typical CLT connections, 11th World Conference on Timber Engineering (WCTE 2010), Riva del Garda, Italy, 2010.
13. Shear performance of tongue-and-groove joints for CLT10.1016/j.conbuildmat.2022.126449 ↗
14. Mechanics-based analytical models for balloon-type cross-laminated timber (CLT) shear walls under lateral loads10.1016/j.engstruct.2019.109916 ↗
15. Lateral resistance of the screwed connections of original bamboo
16. The lateral load resistance of unclassified cross-laminated timber walls: experimental tests and theoretical approach10.1016/j.engstruct.2018.03.077 ↗
17. End distance of single-shear screw connection in cross laminated timber10.5658/WOOD.2017.45.6.746 ↗
18. Structural performance of dowelled cross-laminated timber hold-down connections with increased row spacing and end distance10.1016/j.conbuildmat.2020.121595 ↗
19. Experimental analysis of nailed LBL-to-LBL connections loaded parallel to grain10.1617/s11527-020-01517-5 ↗
20. Numerical and experimental failure analysis of screwed single shear joints in wood plastic composite10.1016/j.matdes.2011.09.061 ↗
21. The effect of GFRP wrapping on lateral performance of double shear lap joints in cross-laminated timber as a part of timber bridges10.3390/buildings12101678 ↗
22. Influence of ply configuration and adhesive type on cross-laminated timber in flexure at elevated temperatures10.1016/j.firesaf.2020.103073 ↗
23. Bending properties of cross laminated timber (CLT) with a 45 alternating layer configuration10.15376/biores.11.2.4633-4644 ↗
24. Influence of layer arrangement on bonding and bending performances of cross-laminated timber using two different species10.15376/biores.15.3.5328-5341 ↗
25. Risk assessment in poplar plantations: a case study from northern Iran10.1007/s11676-019-00895-z ↗
26. Bending and shear properties of cross-laminated timber panels made of poplar (Populus alba)10.1016/j.conbuildmat.2020.120326 ↗
27. Structural performance of hybrid Poplar-Beech cross-laminated-timber (CLT)
28. Z. Wang, H. Fu, Y.-H. Chui, M. Gong, Feasibility of using poplar as cross layer to fabricate cross-laminated timber, Proceedings of the World Conference on Timber Engineering, 2014.
29. Viability of hybrid poplar in ANSI approved cross-laminated timber applications10.1061/(ASCE)MT.1943-5533.0000936 ↗
30. Withdrawal performance of nails and screws in cross-laminated timber (CLT) made of poplar (Populus alba) and fir (Abies alba)10.3390/polym14153129 ↗
31. 1037, standard methods of evaluating the properties of wood-base fiber and particle panel
32. AWC, National design specification for wood construction, AWC Leesburg, VA, 2018.
33. Porteous · 2013
34. C. Group, CSA O86—Engineering Design in Wood, CSA Group: Mississauga, ON, Canada (2019).
35. Failure modes and mechanical properties of bracket anchor connections for cross-laminated-timber, MATEC web of conferences
36. 5961/D 5961 M-05 Standard test method for bearing response of polymer matrix composite laminates
37. Williamson · 2002
38. Lateral resistance of joints made with various screws in commercial wood plastic composites10.1016/j.matdes.2011.03.020 ↗
39. Analysis and tests of lateral resistance of bolted and screwed connections of CLT10.3390/f13030375 ↗