Steel reinforced concrete (SRC) special-shaped columns have the advantages of high spatial utilization, flexible layout and good economic benefits, which are used in high-rise buildings. However, this composite structure has the disadvantages of high steel content and large fire area, which makes it easier to suffer damage in fire, and even cause the collapse of buildings. This paper presents mechanical properties of SRC cross-shaped columns exposed to high temperature. Seven SRC cross-shaped column specimens were analyzed. Temperature field distribution, failure mode, deformation and fire resistance of specimens were obtained under different axial compression ratios (0.4, 0.6) and eccentricity (0, 40, 60, 80 mm). The results showed that: (1) All specimens were in a condition of compression failure and section steel had partial bending failure with the concrete falling off. (2) The larger eccentricity and axial compression ratio were, the earlier cracks appeared, and the more cracks appeared, the more serious concrete shedding of specimen were. Moreover, the cracks were concentrated especially on the side of loading point (i.e., two sides close to the point where the applied load is located), and the cracks are adjacent to the support of specimen, which appear in the whole length of specimen. (3) Axial compression ratio had a significant influence on fire resistance of SRC cross-shaped columns, and influence of eccentricity on fire resistance was generally little compared with axial compression ratio. The fire resistance declined by 43.48–69.14% as axial compression ratio increased from 0.4 to 0.6. Fire resistance declined by 5.45–45.31% as eccentricity increased from 0 to 80 mm, and it was significantly reduced by 28.12–45.31% when axial compression ratio was 0.6. Finally, fire resistance calculation method of SRC cross-shaped column was obtained, which provided reference for fire resistance design of SRC structure.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Li · 2006
2. Effect of high-temperature on the mechanical and durability behaviour of concrete10.1016/j.matpr.2020.11.153 ↗
3. Investigation of concrete encased steel composite columns at elevated temperatures10.1016/j.tws.2010.03.004 ↗
4. Fire resistance of concrete encased steel columns under 3- and 4-side standard heating10.1016/j.jcsr.2010.11.006 ↗
5. Experimental fire resistance of steel reinforced concrete subjected to 3-side heating with a small eccentricity load
6. Prediction of fire resistance of concrete encased steel composite columns using artificial neural network
7. Experimental investigation on fire resistance of high-strength concrete encased steel composite columns
8. Fire performance of steel reinforced concrete columns10.1061/(ASCE)ST.1943-541X.0001081 ↗
9. Performance of axially restrained concrete encased steel composite columns at elevated temperatures10.1016/j.engstruct.2010.10.019 ↗
10. Performance of concrete encased steel stub columns after exposure to high temperatures10.1016/j.jcsr.2021.106934 ↗
11. Thermo-mechanical behaviour of ultra-high strength concrete encased steel columns in standard fires
12. Fire performance of axially restrained steel reinforced concrete columns
13. Study on fire performance of steel reinforced high-strength concrete columns
14. Fire performance study of steel reinforced concrete restrained columns
15. Behaviour of reinforced concrete columns of various cross-sections subjected to fire
16. Fire resistance of reinforced concrete columns with L-, T-, and +-shaped cross-sections10.1016/j.firesaf.2009.04.002 ↗
17. Experimental study on axially restrained reinforced concrete columns with special shaped cross sections under fire
18. Experimental study on reinforced concrete columns with special shaped cross section subjected to high temperature
19. Fire resistance of reinforced concrete columns of T-shaped cross section
20. Fire resistance of reinforced concrete column with L-shaped cross section
21. Fire resistance of reinforced concrete columns with +-shaped cross section
22. Numerical simulation of the mechanical behaviors of RC columns of specially-shaped cross section subjected to high temperature
23. Xu Y.Y., Wu B., Wang R.H. Behavior of Reinforced Concrete Columns with 'T'-shaped Cross Section after Exposure to Fire[C]. //Advanced Building Materials. Part 2.: Trans Tech Publications Ltd, 2011:1696–1701.10.4028/www.scientific.net/AMR.250-253.1696 ↗
24. Performance of T-shaped steel reinforced concrete column under high temperature10.1016/j.proeng.2017.11.115 ↗
25. Structural performance of steel reinforced concrete T-shaped columns exposure to high temperature10.1016/j.istruc.2021.08.023 ↗
26. Mechanical behavior of cross-shaped steel reinforced concrete columns after exposure to high temperatures
27. Experimental research on the fire performance of a special cross-shaped composite column with a high-strength concrete-filled steel tubular core10.1177/1369433217753426 ↗
28. Experimental research on after-fire axial compression performance of cross-shaped composite column with high strength concrete-filled steel tubular core column
29. Residual strength of L-shaped steel reinforced concrete columns after exposure to high temperatures10.1007/s12205-021-0658-9 ↗
30. Experimental investigation on the fire resistance performance of L special-shaped steel reinforced concrete columns10.4028/www.scientific.net/AMM.204-208.3433 ↗
31. Experimental investigation on eccentric compressive behavior of L-shaped SRC columns with unequal limbs after high temperature exposure
32. Temperature field analysis of steel reinforced concrete special-shaped columns
33. Seismic behavior of steel reinforced concrete cross-shaped columns after exposure to high temperatures
34. GB 50016–2014, Code for fire protection design of buildings[S]. in Chinese.