Interstitial hygrothermal analysis for retrofitting exterior concrete wall of modern heritage building in Korea
Source abstract
Abstract
Retrofitting modern heritage buildings aims at not only energy conservation, but also restoration and preservation of an architectural artefact. However, if envelope construction is adjusted and HVAC systems are replaced, the temperature and humidity profiles and air-tightness can also be transitional, thus condensation could occur on the surface and/or inside the structure. It is continuously emphasized to assess retrofit measures’ expected transitions in the hygrothermal performance of envelope and their potential condensation problems, prior to actual retrofit. The present study measured the surface moisture content of the concrete structure and built environment of three modern heritage buildings in Seoul. These results were used as the initial conditions for the hygrothermal analysis of insulations and vapor retarder. One modern heritage school was chosen for retrofit, then mock-up test, ISO 13788 steady-state analysis, and dynamic simulations by WUFI were used to analyze the risk of interstitial condensation in the exterior wall, according to the initial moisture content of concrete wall and whether the vapor retarder had been installed. For modern heritage buildings with fully dry concrete walls, the mock-up test verified that the risk of interstitial condensation between the concrete and insulation is low, regardless of whether the vapor retarder had been installed. Per ISO 13788 steady-state analysis and WUFI transient simulation, if PF board was used as the internal insulation for concrete exterior wall, the chance of interstitial condensation was also low, regardless of the initial moisture content and the use of a vapor retarder.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Hygrothermal properties of building materials · Building Energy and Comfort Optimization · Building materials and conservation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Korea Ministry of Land Infrastructure and Transport, Notification No.2017–881, Building Energy Design Guidelines, 2017.
2. ASHRAE, ASHRAE Guideline, 34–2019 Energy Guideline for Historical Buildings, 2019.
3. Historic England, Energy Efficiency and Historic Building: Application of Part L of the Building Regulations to Historic and Traditionally Constructed Buildings, 2017.
4. Istituto Piligrafico e Zecca dello Stato, Code of cultural heritage and landscape in Italy, 2004, 〈https://www.normattiva.it/uri-res/N2Ls?urn:nir:stato:decreto.legislativo:2004–01-22;42〉 (accessed on 19 October 2020).
5. Canada’s Historic Places, Standards and guidelines for the conservation of historic places in Canada, 2010.
6. Nickolaj Feldt Jensen, Hygrothermal Analysis of Retrofitted Building in the Campus of Lund University, Lund University Master thesis, 2016.
7. Interior insulation for wall retrofitting – A probabilistic analysis of energy savings and hygrothermal risks10.1016/j.enbuild.2014.12.031 ↗
8. Hygrothermal and energy retrofit planning of masonry façade historic building used as museum and office: A cultural properties case study10.1016/j.energy.2020.117607 ↗
9. The impact of convective vapor transport on the hygrothermal risk of the internal insulation of post-war lightweight prefab housing10.1016/j.enbuild.2019.109418 ↗
10. Comparative study of hygrothermal simulations of a masonry wall10.1016/j.egypro.2017.10.027 ↗
11. Analysis of the vapor barrier regulations of the korean building design criteria for energy saving via hygrothermal simulations10.21086/ksles.2019.02.26.1.1 ↗
12. Hygrothermal analysis of technical solutions for insulating the opaque building envelope10.1016/j.egypro.2017.08.141 ↗
13. Comparison of total moisture content by internal condensation evaluation method
14. ISO13788:2012, Hygrothermal Performance of Building Components and Building Elements. Assessment of moisture transfer by numerical simulation, 2012.
15. CSN EN 15026, Hygrothermal Performance of Building Components and Building Elements. Assessment of moisture transfer by numerical simulation, 2007.
16. Fraunhofer IBP, WUFI Pro version6.5.1, www.wufi.com (accessed on 11 June 2021).
17. TQC sheen, LI9200, concrete moisture meter, www.tqcsheen.com (accessed on 11 June 2021).
18. Daeryuk Hall Photo, Public Relations Department of Seoul National University of Science and technology, https://url.kr/hzf1xk (accessed on 11 June 2021).
19. Changhak Hall Photo, Public Relations Department of Seoul National University of Science and technology, https://url.kr/hzf1xk (accessed on 11 June 2021).
20. Dasan Hall Photo, Public Relations Department of Seoul National University of Science and technology, https://url.kr/hzf1xk (accessed on 11 June 2021).
21. SeungEon Lee, Measures for the occurrence and prevention of condensation in buildings, Korea Institute of Civil Engineering and Building Technology, 1998.
22. Sensirion, SHT3X, Digital Humidity Sensor, www.sensirion.com (accessed on 11 June 2021).
23. A study for developing design tools and guidelines to prevent surface condensation in the underground space
24. Korean Standards and Certifications, KS B 6879, Heat Recovery Ventilator, 2020.