journal article·2016-06Open access

Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case study

Krzysztof Zakowski​, Kazimierz Darowicki​, Juliusz Orlikowski​, Agata Jazdzewska​, Stefan Krakowiak​, Maciej Gruszka, Jacek Banas​

Abstract

Case study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800/1000 m from the point of failure. At the point of failure stray currents flowed from the pipeline to the ground through external insulation defects, causing the process of electrolytic corrosion of the metal. Long distance between the affected section of the pipeline and the sources of stray currents excludes the typical protection against stray currents in the form of electrical polarized drainage. Corrosion protection at this point can be achieved by using the earthing electrodes made of magnesium, which will also provide cathodic current protection as galvanic anode.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Concrete Corrosion and Durability · Water Systems and Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. Peabody · 2001
2. von Baeckmann · 1997
3. Effect of cathodic protection on macrocell currents: a viable method to monitor and control the efficiency of CP10.1002/maco.200805033 ↗
4. About corrosion macrocells formed on underground pipelines at the switched off cathodic protection10.1023/A:1010402628789 ↗
5. Metallurgical investigations and corrosion behavior of failed weld joint in AISI 1518 low carbon steel pipeline10.1016/j.engfailanal.2015.03.015 ↗
6. Effects of oxygen and sulfate concentrations on the corrosion behavior of zinc in NaCl solutions
7. Peabody · 2001
8. Stray current control in DC mass transit systems10.1109/TVT.2004.842462 ↗
9. Understanding stray current mitigation, testing and maintenance on DC powered rail transit systems
10. Estimation of stray current from a DC-Electrified railway and impressed potential on a buried pipe10.1109/TPWRD.2012.2211623 ↗
11. Stray currents and pollution of the environment
12. Survey of corrosion cost in China and preventive strategies
13. Stray current corrosion in buried pipeline10.1108/00035591111167695 ↗
14. European standard EN 12501-2: Protection of metallic materials against corrosion. Corrosion likelihood in soil—part 2: low alloyed and non alloyed ferrous materials.
15. ASTM D512-12 · 2012
16. ASTM D516-11 · 2011
17. Javaherdashti · 2013
18. Tsang · 2005
19. Jack · 2002 · vol. 11
20. European standard EN 12954: Cathodic protection of buried or immersed metallic structures—general principles and application for pipelines.
21. The determination and identification of stray current source influences on buried pipelines using time/frequency analysis10.1108/00035590911000313 ↗
22. Potential changes in an electric field and electrolytic corrosion10.1108/00035590310456261 ↗
23. European standard EN 50 162: Protection against corrosion by stray current from direct current systems.
24. Protection of bridges against stray current corrosion10.3846/bjrbe.2015.02 ↗
25. Field experience of remote monitored and controlled CP systems10.1016/j.cscm.2014.12.002 ↗
26. Morgan · 1987