Effect of the insulation materials filling on the thermal performance of sintered hollow bricks under the air-conditioning intermittent operation
Source abstract
Abstract
Wall insulation performance is an important factor affecting building energy consumption and indoor comfortable level. This study proposes that the insulation materials are filled into the cavities of the sintered hollow brick to replace the single insulation layer. The physical models of typical walls were built by the hollow bricks filled with expanding polystyrene board (EPS) in cavities and wall thermal performance is numerically analyzed by the Finite Volume Method under air-conditioning intermittent operation, which conforms to the actual operation rules of air-conditioning. Results show that filling EPS in cavities is beneficial to improve the thermal performance of the bricks, and the larger the EPS filling ratio, the higher the thermal performance improvement. The EPS filling ratio increase has the higher sensitivity on inner surface heat flow under the low EPS filling ratio, and filling EPS in the external cavities is optimum with the decrement rate 5.92% higher than filling EPS in internal cavities for the EPS filling ratio of 20%, while filling EPS in internal and external cavities simultaneously is optimum with decrement rate 2.45%–6.87% higher than that with filling EPS in the internal cavities for the EPS filling ratio of 40%–80%. Keywords: Insulation filling ratio, Insulation filling location, Thermal performance, Sintered hollow bricks
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Building Energy and Comfort Optimization · Hygrothermal properties of building materials · Urban Heat Island Mitigation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. A review on the prediction of building energy consumption10.1016/j.rser.2012.02.049 ↗
2. Cross-cultural assessment of the effectiveness of eco-feedback in building energy conservation10.1016/j.enbuild.2016.11.008 ↗
3. A new simple method to measure wall thermal transmittance in situ and its adaptability analysis10.1016/j.applthermaleng.2017.05.074 ↗
4. Effect of the thermal insulation layer location on wall dynamic thermal response rate under the air-conditioning intermittent operation10.1016/j.csite.2017.04.001 ↗
5. The impacts of daytime external envelope heat gain/storage on the nighttime cooling load and the related mitigation measures in a bedroom in the subtropics10.1016/j.enbuild.2016.02.010 ↗
6. Meng · 2016
7. Study on performance of thick wall type composite sintered shale hollow block
8. Conjugate conduction-natural convection heat transfer in a hollow building block10.1016/j.applthermaleng.2009.04.033 ↗
9. Thermal radiation role in conjugate heat transfer across a multiple-cavity building block10.1016/j.energy.2010.04.055 ↗
10. Numerical simulation of concrete hollow bricks by the finite volume method10.1016/j.ijheatmasstransfer.2009.06.008 ↗
11. Steady state theoretical model of fired clay hollow bricks for enhanced external wall thermal insulation10.1016/j.buildenv.2007.10.005 ↗
12. Numerical thermal optimization of the configuration of multi-holed clay bricks used for constructing building walls by the finite volume method10.1016/j.ijheatmasstransfer.2007.06.008 ↗
13. Numerical analysis by FEM and analytical study of the dynamic thermal behavior of hollow bricks with different cavity concentration10.1016/j.ijthermalsci.2011.02.027 ↗
14. Impact factors analysis on the thermal performance of hollow block wall10.1016/j.enbuild.2014.02.037 ↗
15. Coupled heat and moisture transfer in hollow concrete block wall filled with compressed straw bricks10.1016/j.enbuild.2016.11.026 ↗
16. Experimental and numerical investigation of a hollow brick filled with perlite insulation10.1016/j.enbuild.2010.03.009 ↗
17. Manufacture of high heat conductivity resistant clay bricks containing perlite10.1016/j.buildenv.2006.10.016 ↗
18. Analysis of coupled natural convection conduction effects on the heat transport through hollow building blocks10.1016/j.enbuild.2005.08.010 ↗
19. Thermal comfort in an office with intermittent air-conditioning operation10.1177/0143624409350118 ↗
20. HVAC system operational strategies for reduced energy consumption in buildings with intermittent occupancy: the case of mosques10.1016/j.enconman.2013.04.008 ↗
21. Predictive control of intermittently operated radiant floor heating systems10.1016/S0196-8904(02)00116-4 ↗
22. Improvement of intermittent central heating system of university building10.1016/j.enbuild.2009.07.014 ↗
23. Thermal control of a discontinuously occupied building using a classical and a fuzzy logic approach10.1016/S0378-7788(97)00011-X ↗
24. A numerical comparison of different methods for optimizing heating-restart time in intermittently occupied buildings10.1016/S0306-2619(99)00005-7 ↗
25. An analysis of the performance of different intermittent heating controllers and an evaluation of comfort and energy consumption10.1080/10789669.1997.10391383 ↗
26. Optimal temperature control of intermittently heated buildings using Model Predictive Control: Part I − Building modeling10.1016/j.buildenv.2011.11.009 ↗
27. Optimal temperature control of intermittently heated buildings using Model Predictive Control: Part II – Control algorithm10.1016/j.buildenv.2011.11.008 ↗