Study of shear performance of steel-timber composite connection with different shear connectors
Source abstract
Abstract
The shear resistance of steel-timber composite (STC) connections largely depends on the shear performance of shear connectors. Three types of shear connectors, i.e., welded stud, screw, and screw-grout were considered in this paper. The failure modes, load-slip curves, shear stiffnesses, and shear carrying capacity of the STC connection with three different connectors were experimentally and theoretically investigated under various shear connector diameters and glulam panel thicknesses. The experimental results indicated that the shear carrying capacity and stiffness of the welded stud connections are 1.49 and 5.17 times higher than those of the screw connection under identical cases, respectively. The failure patterns of welded stud connection were characterized by shear failure of the stud, crushing failure in the grout blocks and splitting failure of the glulam panel. In contrast to welded stud connections, screw and screw-grout connections exhibited significant crushing failure of glulam. It indicated that the grout used in welded stud connection can effectively mitigate or avoid crushing failure in the glulam panel. A simplified and feasible theoretical formula was developed to predict the shear carrying capacity of the STC connection with welded stud connector. Compared with the predictions of GB 50017-2017, AISC 360-16, and EC 4, the developed formula for the shear carrying capacity of welded stud connection provided a reasonable prediction with an error within 15%. • The shear performance of steel-timber composite (STC) connection with various shear connectors was experimentally and theoretically investigated. • The STC connection with welded stud shear connectors embedded in high-strength grout can effectively weaken or avoid crushing failure in the glulam panel. • The STC connection with welded stud shear connectors demonstrated stronger shear carrying capacity than those of the screw connections. • A simplified theoretical formula to accurately predict the shear carrying capacity of the STC connection with welded stud shear connectors was developed.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Structural Load-Bearing Analysis · Tree Root and Stability Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Assessment of bonding durability of CLT and glulam made from oak and mixed poplar-oak according to bonding pressure and glue type10.1016/j.conbuildmat.2022.127345 ↗
2. Glulam beam made from hydrothermally treated poplar wood with reduced moisture induced stresses10.1016/j.conbuildmat.2016.12.178 ↗
3. Experimental and numerical study of steel-timber composite (STC) beams10.1016/j.jcsr.2016.04.005 ↗
4. Experimental and numerical investigation of short-term behaviour of CLT-steel composite beams10.1016/j.engstruct.2017.04.052 ↗
5. Connections for steel–timber hybrid prefabricated buildings. Part I: experimental tests10.1016/j.conbuildmat.2015.12.002 ↗
6. Connections for steel–timber hybrid prefabricated buildings. Part II: innovative modular structures10.1016/j.conbuildmat.2015.12.001 ↗
7. Experiments of load-carrying capacity of bolted connections in timber structures and determination of design value
8. Experimental study of thin-walled steel-timber single-shear connection with a self-tapping screw10.1016/j.istruc.2021.10.028 ↗
9. Mechanical behaviour of steel timber composite shear connections10.1016/j.conbuildmat.2020.119605 ↗
10. Experimental study of the shear performance of H-shaped aluminum-timber composite connections10.1016/j.conbuildmat.2022.127421 ↗
11. Experimental investigation of the shear characteristics of steel-to-timber composite joints with inclined self-tapping screws10.1016/j.engstruct.2020.110683 ↗
12. Self-tapping screws and threaded rods as reinforcement for structural timber elements - a state-of-the-art report10.1016/j.conbuildmat.2015.04.028 ↗
13. Experimental study on shear performance of steel-timber screw connectors with grout blocks10.1016/j.engstruct.2022.114535 ↗
14. Enhance the performance of steel-wood composite screw connections with fast-curing adhesive
15. Innovative shear connectors for composite cold-formed steel-timber structures: an experimental investigation[J]10.1016/j.engstruct.2023.116120 ↗
16. Experimental investigation on novel shear connections for demountable steel-timber composite (STC) beams and flooring systems10.1016/j.engstruct.2024.117620 ↗
17. Load-slip behaviour of steel-cross laminated timber (CLT) composite connections10.1016/j.jcsr.2016.03.008 ↗
18. Composite connections between CLT slab and steel beam: experiments and empirical models10.1016/j.jcsr.2017.09.002 ↗
19. High-performance grout-reinforced shear connectors for hybrid steel-cross-laminated timber building systems: experimental study
20. Experiment and design approach of steel-to-laminated bamboo lumber screwed connections under load parallel to grain10.1016/j.jclepro.2022.134964 ↗
21. Cyclic behaviour of bolt and screw shear connectors in steel-timber composite (STC) beams10.1016/j.jcsr.2019.05.048 ↗
22. Shear performance of grouted stud connectors for steel–CLT composite beams
23. Static behavior of multi-stud shear connectors for steel-concrete composite bridge10.1016/j.jcsr.2011.09.017 ↗
24. Study on mechanical properties of stud connectors in steel-lightweight aggregate concrete composite structures10.1016/j.istruc.2022.11.145 ↗
25. GB 50017-2017 · 2017
26. GB/T 10433-2002 · 2002
27. GB/T 102-1986 · 1986
28. ASTM F1575-03 · 2008
29. GB 50010-2010 · 2010
30. B.S. EN, 26891-1991 · 2000
31. ASTM D5764-97a · 2018
32. EN 1995-1-1 · 2004
33. Zhu · 2017
34. Larsen · 2009 · 194
35. Studies of nail connectors used in wood frame shear walls with ply-bamboo sheathing panels10.1061/(ASCE)MT.1943-5533.0001167 ↗
36. Experimental study on the withdrawal performance of mortar-glulam hybrid anchored screws10.1016/j.conbuildmat.2023.133439 ↗
37. ANSI/AISC 360-16 · 2016
38. EN 1994-1-1:2004 · 2004
39. Finite element modeling on shear performance of grouted stud connectors for steel-timber composite beams