Mechanical behavior of grouted sleeve connection for rebars in precast concrete structures and reliability analysis considering the ratio of anchorage length to rebar diameter
Source abstract
Abstract
Grouted sleeve connection is the widely used method for the connection of stressed steel reinforcement bars in precast concrete structure. The reliability of the connection depends on the bond strength between the steel bars and the grouting materials. In this study, the uniaxial tensile test of 204 grouted sleeve connection specimens was carried out. The test parameters included steel bar diameter, steel bar anchorage length, grouting material strength, etc. Test results indicate that there are two main failure modes for the specimens, steel reinforcement tensile fracture and bond failure, which are mainly affected by the anchorage length of steel bars. When the anchorage length is greater than 5 d s , the main failure mode is steel bar tension fracture. Furthermore, 236 sets of data in the relevant literatures were collected. Combined with the experimental data, a database of bond strength between steel bars and grouting materials containing 334 sets of data was established, and a calculation formula of ultimate bond strength of grouted sleeve with high applicability was proposed. Finally, the reliability of the grouted sleeve connection with different anchorage lengths and the failure probability under different anchorage lengths were analyzed. On this basis, the minimum anchorage length for different types of steel bars was proposed. The minimum anchorage length of HRB400 steel bars ranges from 5 d s to 8 d s , the minimum anchorage length of HRB500 steel bars ranges from 7 d s to 10 d s , and the minimum anchorage length of HRB600 steel bar ranges from 9 d s to 12 d s .
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Cyclic response of precast concrete shear walls with reduced grouted sleeves or corrugated metallic duct splices
2. Numerical study on the influence of geometric parameters on mechanical properties of tapered head grouted sleeve joints
3. Bond behavior of spirally confined splice of deformed bars in grout10.1016/j.conbuildmat.2014.12.097 ↗
4. Study of effects of sleeve grouting defects on the seismic performance of precast concrete shear walls10.1016/j.engstruct.2020.111833 ↗
5. Development and validation of a defect detection and repair method for half grouted sleeve connection
6. Grout-filled pipe splices for precast concrete construction10.15554/pcij.01011995.82.93 ↗
7. Effects of spiral confinement to the bond behavior of deformed reinforcement bars subjected to axial tension10.1016/j.engstruct.2015.12.038 ↗
8. Kim, H.K.; A Study of Pipe Splice Sleeves For Use In Precast Beam-column Connections. Ph.D. Thesis, University of Texas at Austin, Texas, USA, 2000.
9. Structural performance of steel pipe splice for SD500 high -strength reinforcing bar under cyclic loading
10. Analysis of spiral reinforcement in grouted pipe splice connectors
11. Structural performance of grouted sleeve connectors with and without transverse reinforcement for precast concrete structure10.1016/j.proeng.2013.02.017 ↗
12. Performance of grouted splice sleeve connector under tensile load10.15282/jmes.7.2014.8.0106 ↗
13. The relationship between interlocking mechanism and bond strength in elastic and inelastic segment of splice sleeve10.1016/j.conbuildmat.2014.01.020 ↗
14. Effective of elastic and inelastic zone on behavior of glass fiber reinforced polymer splice sleeve10.1016/j.conbuildmat.2015.01.064 ↗
15. Tensile capacity of grouted splice sleeves10.1016/j.engstruct.2015.12.023 ↗
16. Tensile strength of the grout-filled head-splice-sleeve10.1016/j.conbuildmat.2016.07.028 ↗
17. An experimental study of welded bar sleeve wall panel connection under tensile, shear, and flexural loads10.1007/s40069-017-0202-y ↗
18. Design recommendations for grouted pile sleeve connections10.1016/j.marstruc.2018.03.001 ↗
19. Experimental investigation of hybrid mechanical joints for L-shaped columns replacing conventional grouted sleeve connections10.1016/j.engstruct.2019.01.123 ↗
20. On the early-age bond-slip behavior of an eccentric bar embedded in a grouted sleeve10.1016/j.engstruct.2019.04.020 ↗
21. Ministry of Housing and Urban-Rural Development of the People's Republic of China. Technical specification for grout sleeve splicing of rebars: JGJ 355–2015. Beijing: China Architecture & Building Press, 2015.
22. Full-range mechanical behavior study of FRP-to-concrete interface for pull-pull bonded joints10.1016/j.compositesb.2018.11.030 ↗
23. Evaluation of common defects of grouted sleeve connectors
24. Experimental research on effects of grout age and types of steel bars on mechanical behavior of grout sleeve splicing for reinforcing bars
25. Experimental study on the behavior of grouted deformed pipe splice
26. Experimental study and finite element analysis on behavior of deformed gout-filled pipe splice
27. Research on rebar splicing system by GDPS grout-filled coupling sleeve
28. Research report on grouting defect treatment technology of huarun land sleeve
29. Experimental study on the bonding performance and analysis of bond anchoring reliability of half grouting sleeve connection
30. Experimental study on bond-slip performance of steel bars and sleeve constrained grouting material
31. Behavior of grouted pipe splice under incremental tensile load10.1016/j.conbuildmat.2012.02.001 ↗
32. Feasibility study of grouted splice connector under tensile load10.1016/j.conbuildmat.2013.10.010 ↗
33. Non-proprietary bar splice sleeve for precast concrete construction10.1016/j.engstruct.2014.10.045 ↗
34. Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Unified standard for reliability design of building structures: GB 50068–2018; Beijing: China Architecture & Building Press, 2018.
35. Reliability assessment for flexural FRP-Strengthened reinforced concrete beams based on importance sampling10.1016/j.compositesb.2018.09.002 ↗