RETRACTED: A study on thermal analysis of under-construction concrete dam
This record is marked as retracted by the source. Review the publisher’s notice before using its findings.
Source abstract
Abstract
This paper represents the thermal analysis of an under-construction concrete dam. The temperature distribution of the Dasu dam was analyzed by the thermal and heat of hydration model in this case study. An exponential function was used for the heat of hydration because an adiabatic calorimetric test was not available for the concrete mixture in Dasu. Hydration heat is estimated at five, nine, and twenty-nine days. The temperature monitoring system was installed at the dam site to record the actual temperature and it was compared with the predicted temperature using formulas. It is also necessary to note that the cooling of concrete starts from the bottom with the help of piped water. To facilitate the grouting of contractions joint, was the purpose of post-cooling by piped water. Concrete cooling with the help of piped water is not modeled by thermal code. Therefore its evaluation of temperate was not possible to simulate at that starting stage. Let us compare the observed temperature and calculated it, for the middle blocks eight-nine and thirteen-fourteen the height of the blocks is 96.00 m and the cross-section is also the same. The value was the same for the observed temperature and calculated before applying post cooling. It was observed that air temperature also has influenced due to seasonal variation near dam surfaces. The study outcomes stand unlimited influence to notice the engineers proceed with distinct measures in the design and structure of the recent concrete dam for reducing the possibility of cracking in the structure and optimizing the construction schedules.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dam Engineering and Safety · Geotechnical Engineering and Analysis · Hydraulic flow and structures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. E.M. Castilho, N.S. Leitão, C. Tiago, Thermal analysis of concrete dams during construction phase, Paper presented at the Second International Dam World Conference, 2015.
2. Thermo-chemo-mechanical model for concrete. I: Hydration and aging10.1061/(ASCE)0733-9399(1999)125:9(1018) ↗
3. Thermo-chemo-mechanical model for concrete. II: Damage and creep10.1061/(ASCE)0733-9399(1999)125:9(1028) ↗
4. Simulation of construction of RCC dams. I: temperature and aging10.1061/(ASCE)0733-9445(2000)126:9(1053) ↗
5. Assessment of temperature evolution and early-age thermal cracking risk in segmental high-strength concrete box girder diaphragms10.1007/s12205-021-2148-5 ↗
6. Thermal-structural modeling and temperature control of roller compacted concrete gravity dam10.1061/(ASCE)0887-3828(2003)17:4(177) ↗
7. Thermal stress analysis of a concrete dam10.1016/0045-7949(91)90360-X ↗
8. Chemoplastic material model for the simulation of early-age cracking: from the constitutive law to numerical analyses of massive concrete structures10.1016/S0958-9465(03)00071-4 ↗
9. Simulation of temperature and stress fields during RCC dam construction10.1061/(ASCE)0733-9364(2000)126:5(381) ↗
10. L.M.G.d. Silva, Caracterização das propriedades termo-mecânicas do betão nas primeiras idades para aplicação estrutural, 2007.
11. Modeling of thermochemomechanical couplings of concrete at early ages10.1061/(ASCE)0733-9399(1995)121:7(785) ↗
12. Analysis of cracking mechanism of concrete galleries in a super high arch dam10.1016/j.engstruct.2021.113227 ↗
13. Characteristics and causes of crest cracking on a high core-wall rockfill dam: a case study10.1016/j.enggeo.2021.106488 ↗
14. Optimization of the temperature control scheme for roller compacted concrete dams based on finite element and sensitivity analysis methods
15. Feedback design of temperature control measures for concrete dams based on real-time temperature monitoring and construction process simulation10.1007/s12205-017-1935-5 ↗