Upgrading cyclic response of heat-damaged RC beam-column joints using CFRP sheets

Ayah A. Alkhawaldeh, Rajai Z. Al-Rousan

Abstract

In this study, experimental work is used to determine the efficacy of carbon fiber reinforced polymer (CFRP) sheets, which are used as externally bonded reinforcement in recovering the structural performance and mitigating the failure mechanism of heat-damaged reinforced concrete (RC) beam-column joints. Twelve RC beam-column joints were cast in-house and classified into three batches: four joints were kept at ambient temperature, four joints were subjected to 400 °C temperature, and four joints were subjected to 600 °C temperature. Following the addition of one, two, or three layers of CFRP sheets for reinforcement, three joints from each batch were tested under a quasi-static cyclic load. The ultimate load capacity in pulling and pushing, as well as its corresponding lateral displacement, horizontal load-lateral displacement envelopes, energy dissipation, displacement ductility, and stiffness degradation, were all considered while evaluating the structural performance of the joints. The experimental results showed that the cyclic performance of heat-damaged RC beam-column joints strengthened with CFRP sheets had improved (greater lateral displacement, higher load capacity, higher energy dissipation, higher displacement ductility, and slower secant stiffness degradation). Additionally, when heat damage increases in severity, CFRP sheets become more effective.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Fire effects on concrete materials · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Seismic upgrade of interior beam-column subassemblages with high-performance fiber-reinforced concrete jackets
2. Consequence of Anchoring Holes Technique on the Bond Behavior Between CFRP Composites and Heat-damaged Concrete
3. Triantafyllou, G., Rousakis, T., Karabinis, A. ,2019. Corroded RC Beams at Service Load before and after Patch Repair and Strengthening with NSM CFRP Strips. In Buildings (Vol. 9, Issue 3, p. 67). MDPI AG. https://doi.org/10.3390/buildings9030067.10.3390/buildings9030067 ↗
4. Spinella, N., Colajanni, P., Recupero, A., Tondolo, F. ,2019. Ultimate Shear of RC Beams with Corroded Stirrups and Strengthened with FRP. In Buildings (Vol. 9, Issue 2, p. 34). MDPI AG. https://doi.org/10.3390/buildings9020034.10.3390/buildings9020034 ↗
5. Fathalla, E., Salem, H. ,2018. Parametric Study on Seismic Rehabilitation of Masonry Buildings Using FRP Based upon 3D Non-Linear Dynamic Analysis. In Buildings (Vol. 8, Issue 9, p. 124). MDPI AG. https://doi.org/10.3390/buildings8090124.10.3390/buildings8090124 ↗
6. Manie, S., Jami, E., Azarian, Z. ,2017. Simplified Design of FRP-Confined Square RC Columns under Bi-Axial Bending. In Buildings (Vol. 7, Issue 4, p. 74). MDPI AG. https://doi.org/10.3390/buildings7030074.10.3390/buildings7030074 ↗
7. Seismic performance of interior reinforced concrete beam–column joint with corroded reinforcement
8. Effects of elevated temperatures on properties of concrete10.1016/j.firesaf.2007.01.003 ↗
9. The effect of high temperatures on the mechanical properties of concrete made with different types of aggregates10.1016/j.firesaf.2011.07.002 ↗
10. Modelling of heated concrete10.1680/macr.2002.54.2.77 ↗
11. Concrete strength for fire safety design10.1680/macr.2005.57.8.445 ↗
12. Bažant, Z.P., Kaplan, M.F., Bazant, Z.P. ,1996. Concrete at high temperatures: material properties and mathematical models.
13. Residual bond strength between steel bars and concrete after elevated temperatures10.1016/j.firesaf.2009.04.001 ↗
14. Evolution of the bond strength between reinforcing steel and fibre reinforced concrete after high temperature exposure10.1016/j.conbuildmat.2018.05.065 ↗
15. Behavior of heated damaged reinforced concrete beam-column joints strengthened with FRP
16. Numerical simulation of the influence of bond strength degradation on the behavior of reinforced concrete beam-column joints externally strengthened with FRP sheets
17. Lateral load response of strengthened reinforced concrete beam-to-column joints
18. Prota, A., Nanni, A., Manfredi, G., Cosenza, E. ,2001, December. Selective upgrade of beam-column joints with composites. In Proceedings of the international conference on frp composites in civil engineering (Vol. 1, pp. 919–926).
19. Cyclic behavior of HPFRC-repaired reinforced concrete interior beam-column joints10.1007/BF02483154 ↗
20. Seismic performance of RC beam–column joints constructed with engineered cementitious composites10.1061/(ASCE)ST.1943-541X.0002824 ↗
21. Seismic performance of reinforced concrete beam–column joint strengthening by frp sheets10.1016/j.istruc.2019.04.007 ↗
22. Efficiency of externally bonded L-shaped FRP laminates in strengthening reinforced-concrete interior beam-column joints10.1061/(ASCE)CC.1943-5614.0000622 ↗
23. Retrofitting external RC beam-column joints of an ordinary MRF through plastic hinge relocation using FRP laminates10.1016/j.istruc.2019.08.004 ↗
24. Retrofitting of partially damaged reinforced concrete beam-column joints using various plate-configurations of CFRP under cyclic loading10.1016/j.conbuildmat.2018.11.267 ↗
25. Shear retrofitting of corner 3D-reinforced concrete beam-column joints using externally bonded CFRP reinforcement on grooves10.1061/(ASCE)CC.1943-5614.0000862 ↗
26. Seismic evaluation of ordinary RC buildings retrofitted with externally bonded FRPs using a reliability-based approach10.1016/j.compstruct.2019.111567 ↗
27. Hybrid CFRP-steel for enhancing the flexural behavior of reinforced concrete beams10.1016/j.jksues.2020.06.004 ↗
28. Behavior of RC beams with different bond strength
29. Effectiveness of externally bonded and near surface–mounted CFRP reinforcement in flexural strengthening of RC beams: numerical approach10.1061/(ASCE)SC.1943-5576.0000687 ↗
30. Seismic performance of corroded reinforced concrete beam-column joints repaired with BFRP sheets10.1016/j.conbuildmat.2021.124731 ↗
31. Experimental studies on the seismic behavior of reinforced concrete beam-column joints strengthened with basalt fiber-reinforced polymer sheets10.1016/j.conbuildmat.2021.122901 ↗
32. Rehabilitation of seismic-damaged reinforced concrete beam-column joints with different corrosion rates using basalt fiber-reinforced polymer sheets10.1016/j.compstruct.2022.115397 ↗
33. FRP composites strengthening of concrete columns under various loading conditions10.3390/polym6041040 ↗
34. Al-Kamaki, Y.S., Al-Mahaidi, R., Mohammed, A.A. (2014). Behavior of concrete damaged by high temperature exposureand confined with CFRP fabrics.
35. Effect of carbon fiber reinforced polymer confinement on the fire damaged and un-heated reinforced concrete square columns
36. ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318–95) and Commentary (318R-95),” American Concrete Institute, Farmington Hills, Mich., 1995, 369 pp.
37. ISO 834–1. (1999). Fire-resistance tests-elements of building construction, Part 1: General Requirements. International Organization for Standardization, 1–25.
38. ASTM. (2001). ASTM E119: Standard test methods for fire tests of building construction and materials. West Conshohocken, Pa: ASTM.
39. ACI440 Committee. (2017). ACI 440.2 R-17. American Concrete Institute.
40. ACI Committee 318. (2020). Building Code Requirements for Structural Concrete (ACI 318–19): An ACI Standard; Commentary on Building Code Requirements for Structural Concrete (ACI 318R-19). American Concrete Institute.
41. Paulay · 1992