Improving half-cell potential survey through computational inverse analysis for quantitative corrosion profiling

Ramzi Adriman, Israr Bin M. Ibrahim, Syifaul Huzni, Syarizal Fonna, Ahmad Kamal Ariffin

Abstract

Corrosion of reinforcing steel is the primary cause of reinforced concrete (RC) premature failure. Half-cell potential survey based on ASTM C876 is a widely-used method to evaluate RC corrosion. However, the quality of the survey depends on the amount of data acquired, and data acquisition translates into labor time. Low quality surveys may lead to poor evaluation and misleading assessment. This study demonstrates that field survey augmented with computational methods is a promising approach to an improved diagnosis of RC corrosion. The approach augments field data from half-cell potential survey with computational method to diagnose the location and size of corrosion in the reinforcing steel of RC. The computational method integrates Particle Swarm Optimization into Boundary Element Method to carry out inverse analysis. The effectiveness of the approach was tested for an RC column of a local building affected by the 2004 Indian Ocean tsunami. The half-cell potential survey was used to find the general location of the corrosion in the RC. The computational inverse analysis was then used to diagnose the location and size of the corrosion based on the acquired field data. The actual corrosion location and size were then confirmed by breaking up the RC column. It was found that the approach was able to diagnose the location and size of corrosion up to 95.65% of accuracy. This study concludes that computational inverse analysis is a promising venture to improve the quality of and extend the usability of the half-cell potential survey for quantitative corrosion profiling.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Non-Destructive Testing Techniques · Structural Health Monitoring Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. NACE International, International Corrosion Cost and Preventive Strategies in the United States, New York, 2002.
2. Jackson J.E., Cost of Corrosion Annually in the US Over $1 Trillion, 2013. 〈http://www.g2mtlabs.com/cost-of-corrosion〉. [14 July 2019].
3. Roberge · 2008
4. The World Bank Group, Indonesia, 2019. 〈https://data.worldbank.org/country/indonesia〉. [20 July 2019].
5. Nag O.S., Countries with the Longest Coastline, 2018. 〈https://www.worldatlas.com/articles/countries-with-the-most-coastline.html〉. [20 July 2019].
6. Mathematical models to predict the mechanical behaviour of reinforcements depending on their degree of corrosion and the diameter of the rebars10.1016/j.conbuildmat.2014.03.003 ↗
7. Ferguson E., Corrosion likely culprit in roof collapse: expert, 2012. 〈http://www.thewhig.com/2012/06/25/corrosion-likely-culprit-in-roof-collapse-expert〉. [18 August 2013].
8. Latief, Struktur Wahana Atlantis Dikaji Ulang, 2011. 〈http://megapolitan.kompas.com/read/2011/09/28/12185069/Struktur.Wahana.Atlantis.Dikaji.Ulang〉. (in Indonesian) [28 April 2016].
9. A.K. Constantino, Final missing person identified in Florida condo collapse, bringing death toll to 98, 2021. 〈https://www.cnbc.com/2021/07/26/florida-condo-collapse-final-missing-person-identified-death-toll-98.html〉. [16 August 2021].
10. The Visual Journalism Team, Miami building collapse: what could have caused it?, 2021. 〈https://www.bbc.com/news/world-us-canada-57651025〉. [16 August 2021].
11. Inverse analysis using particle swarm optimization for detecting corrosion profile of rebar in concrete structure10.1016/j.enganabound.2013.01.005 ↗
12. Boundary element inverse analysis for rebar corrosion detection: study on the 2004 tsunami-affected structure in Aceh
13. Probe electrode for contactless potential measurement on concrete – properties and corrosion profiling application10.1016/j.corsci.2011.11.007 ↗
14. ASTM C876-15, Standard Test Method for Corrosion Potentials of Uncoated Reinforcing Steel in Concrete. ASTM International, West Conshohocken, PA, 2016. 〈https://doi.org/10.1520/C0876-15〉.10.1520/C0876-15 ↗
15. Broomfield · 2007
16. Model-assisted non-destructive monitoring of reinforcement corrosion in concrete structures. Nondestructive testing of materials and structure10.1007/978-94-007-0723-8_102 ↗
17. Simulation of the ill-posed problem of reinforced concrete corrosion detection using boundary element method
18. Corrosion resistance of self-consolidating concrete in full-scale reinforced beams10.1016/j.cemconcomp.2008.10.005 ↗
19. Babaei K., Evaluation of Half-Cell Corrosion Detection Test for Concrete Bridge Decks, Final Report, Washington State Department of Transportation (WSDOT), 1986.
20. Corrosion monitoring of reinforced concrete structures – a review10.1016/S1452-3981(23)17049-0 ↗
21. Half-cell potential mapping to assess repair work on RC structures10.1016/S0950-0618(00)00062-3 ↗
22. Boundary element simulation for identification of steel corrosion in concrete by magnetic field measurement10.5006/1.3278213 ↗
23. Half-cell potential measurement—potential mapping on reinforced concrete structures10.1007/BF02481526 ↗
24. Simulation of sacrificial anode protection for steel platform using boundary element method10.1016/j.enganabound.2011.07.018 ↗
25. Non-destructive investigation of corrosion current density in steel reinforced concrete by artificial neural networks10.1016/j.acme.2012.10.007 ↗
26. A multistep genetic algorithm for detecting corrosion of reinforcing steels in concrete10.5006/1.3280614 ↗
27. Corrosion detection in concrete structure including layered rebar10.4028/www.scientific.net/KEM.462-463.1255 ↗
28. An efficient inverse analysis considering observation error to detect corrosion in concrete structures containing multilayered rebar10.1007/s10999-012-9178-6 ↗
29. Inverse radiation analysis using repulsive particle swarm optimization algorithm10.1016/j.ijheatmasstransfer.2007.09.037 ↗
30. Parsopoulos · 2010
31. Some electrochemical aspects of corrosion of steel in concrete10.5006/1.3582998 ↗
32. Brebbia · 2001
33. Prediction of galvanic corrosion rates by the boundary element method10.1016/0895-7177(91)90049-D ↗
34. Fonna S., Julianda A., Kurniawan R., Huzni S., Ariffin A.K., The Influence of Social Parameter in Detecting the Corrosion Location of Reinforced Concrete Using Inverse Analysis Based on BEM-PSO, Numerical Analysis in Engineering (NAE) 2019, 20–22 August 2019, Bandar Baru Bangi, Malaysia, 2019.
35. Fonna S., Gunawarman, Huzni S., Inconstant inertia weight for boundary element inverse analysis to detect RC corrosion. in: Proceedings of the IEEE Conference: 2018 International Conference on Applied Science and Technology (iCAST), 2018, pp, 146–50.10.1109/iCAST1.2018.8751258 ↗
36. The influence of number of solution candidate on the performance of boundary element inverse analysis in detecting rebar corrosion10.1088/1757-899X/602/1/012066 ↗
37. Factors influencing half-cell potential measurement and its relationship with corrosion level10.1016/j.measurement.2017.03.027 ↗
38. Gu · 1998
39. Boundary element inverse analysis by using particle swarm optimization for reinforced concrete corrosion identification10.4028/www.scientific.net/AMR.339.171 ↗
40. Pre and post processing for boundary element method (BEM) 3D reinforced concrete corrosion simulation10.4028/www.scientific.net/KEM.462-463.230 ↗
41. Simulation of the ill-posed problem of reinforced concrete corrosion detection using boundary element method
42. A physics-informed deep learning framework for inversion and surrogate modeling in solid mechanics10.1016/j.cma.2021.113741 ↗
43. Comparison of GA and PSO in boundary element inverse analysis for rebar corrosion detection10.4028/www.scientific.net/AMM.471.319 ↗
44. Model-assisted non-destructive monitoring of reinforcement corrosion in concrete structures
45. Artificial neural networks used in optimization problems10.1016/j.neucom.2017.04.075 ↗
46. Analysis of half-cell potential measurement for corrosion of reinforced concrete10.1016/j.conbuildmat.2003.10.004 ↗
47. IBEM analyses on half-cell potential measurement for NDE of rebar corrosion10.12989/cac.2007.4.4.285 ↗
48. Virtual reality presentation for nondestructive evaluation of Rebar corrosion in concrete based on inverse BEM
49. Compensation procedure for half-cell potential measurement10.1016/S0950-0618(97)00028-7 ↗
50. Quantitative interpretation of half-cell potential measurements in concrete structures10.1061/(ASCE)0899-1561(2009)21:9(467) ↗
51. Corrosion risk assessment of public buildings affected by the 2004 Tsunami in Banda Aceh10.1142/S1793431113500048 ↗