Evaluation of polyurethane resin injection for concrete leak repair
Source abstract
Abstract
The aim of this study is to evaluate the effectiveness of water leakage treatment using polyurethane resin injection for concrete structure elements. Water leakage may have destructive effects on building structures. Leaks may be attributed to several factors, such as the use of an inadequate waterproofing system, inadequate design, poor concrete quality, and poor workmanship.A wide range of techniques and products are employed to control water intrusion, including resin injection, which is among the methods commonly used for resolving leakage in waterproofing systems. The aforementioned techniques and products also provide special solutions for other construction problems. In this study, the effectiveness of using resin injection to stop water leakage is investigated. As part of the experimental work, two water tanks are modelled to simulate actual field conditions. The tanks are filled with pumped water, and three measured water pressure values are investigated to determine the effectiveness of resin injection method. The water pressure is gradually increased up to 3 bar (43.5 psi) for three days, and relevant pressure reductions are determined in each case. The results indicate that the ability of concrete elements to resist water flow is inadequate when a waterproofing system is not employed (Case 1); however, concrete permeability is slightly reduced when waterproofing materials are used (Case 2). More specifically, the use of polyurethane resin injection can substantially stop water leaks (Case 3). Polyurethane resins are designed to expand with water to permanently block the passage of water through cracks or voids. Their fast expansive reaction with water forms a tough and flexible/elastic foam. The analysis demonstrates the reduction in concrete permeability after the application of polyurethane resin injection. The results obtained in this research can be utilised as a solution to stop water leaks and cracks in concrete elements, such as basement walls, manholes, tunnels, storm sewers, retaining walls, seawalls, dams, below-grade parking decks, water treatment tanks, elevator pits, box culverts, below-grade vaults, walls, pits, and floors. Keywords: Leakage, Water leakage treatment, Water pressure, Resin, Concrete
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Drilling and Well Engineering · Concrete Properties and Behavior · Grouting, Rheology, and Soil Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. By Scott “Spiderman” Mulholland "Water Intrusion Causes Major Problems before and after Construction” US Building Consultants Inc, July 1, 2011. https://www.publicadjuster.com/Portals/0/docs/Related_Articles/Water%20Intrusion%20Causes%20Major%20Problems%20Before%20and%20After%20Construction.pdf.
2. SIKA–Waterproofing-Solutions for Water Seal, using SIKA Injection Systems in Concrete, Masonry and Natural Stone Structures (in Portuguese). SIKA Brazil Marketing Catalog. Available online at http://bra.sika.com (September 2015).
3. 2016
4. Brent Anderson · 2018
5. ACI 503R-93, Use of Epoxy Compounds with Concrete (Reapproved 1998) American Concrete Institute.
6. Gerber · 2016
7. ACI 224.1R-93, Causes, Evaluation and Repair of Reapproved 1998 Cracks in Concrete Structures (Reapproved 1998) American Concrete Institute.
8. BASF–European Standard EN 1504-Illustrated Guide, simplified for all Involved in Concrete Repair (in Portuguese). Available online at www.basf.pt (November 2015).
9. EN 1504-1:2005–Products and systems for the protection and repair of concrete structures. Definition, requirements, quality control and evaluation of conformity. Part 1: Definitions, CEN. 10.
10. EN 1504-3:2005–Products and systems for the protection and repair of concrete structures. Definition, requirements, quality control and evaluation of conformity. Part 3: Structural and nonstructural repair, CEN.
11. EN 1504-5:2005–Products and systems for the protection and repair of concrete structures. Definition, requirements, quality control and evaluation of conformity. Part 5: Concrete injection, CEN.
12. EN 1504-8:2005–Products and systems for the protection and repair of concrete structures. Definition, requirements, quality control and evaluation of conformity. Part 8: Quality control and certification quality, CEN.
13. EN 1504-9:2008–Products and systems for the protection and repair of concrete structures. Definition, requirements, quality control and evaluation of conformity. Part 9: General principles for the use of products and systems, CEN.
14. EN 1504-10:2005–Products and systems for the protection and repair of concrete structures. Definition, requirements, quality control and evaluation of conformity. Part 10: Site application of products and quality control of the works, CEN.
15. SCHMID · 2010
16. de Almeida Araújo · 2016
17. Remediation of leakage through annular cement using a polymer resin: a laboratory study10.1016/j.egypro.2016.01.045 ↗
18. MURRA, Myles A.–Epoxy Injection Welds Cracks Back Together-But materials and methods must be right for the job. Concrete Construction, January 1987. Available online at www.concreteconstruction.net/concrete-articles/ (August 2015).
19. E.S.S. 4765-1/2012 Physical and mechanical properties examination of cement, Part 1. Egyptian Standards Specification, Cairo.
20. E.S.S. 1109/1971, Concrete Aggregates from Natural Sources.
21. ASTM C33, Standard Specification for Concrete Aggregates.