journal article·2019-06Open access

In situ assessment of superficial moisture condition in façades of historic building using non-destructive techniques

Letzai Ruiz Valero, Virginia Flores Sasso, Esteban Prieto Vicioso

Abstract

In historic building the water resistance capacity of their external materials is a relevant property that must be known, because the materials play a fundamental role in the interaction with the external environment. The aim of this research is to evaluate in situ the superficial moisture condition in facades using non-destructive techniques (NDT). Two different moisture measuring NDT was used: Infrared Thermography (IRT) and Electrical Resistance Measuring (ERM); in addition, the Air Temperature and Relative Humidity were measured. The IRT identifies the temperature of the material and offers a thermal image with different temperatures that is interpreted as moisture area. A Moisture Mapping is obtained with ERM, which represents the moisture conditions in the facades. Both techniques give an idea of moisture areas. The results of both graphics shows that the most humid areas correspond to the same areas that obtain by IRT and ERM. In conclusion, using these two NDT at the same time it is possible to acquire usually a quick, qualitative, precise and economic results of: moisture areas in situ, important data to survey and the assessment the historic building for monitoring or preservation project.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Thermography and Photoacoustic Techniques · Conservation Techniques and Studies · Building materials and conservation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Preventive thermographic diagnosis of historical buildings for consolidation10.1016/j.culher.2012.05.005 ↗
2. Tavares · 2005
3. “In situ testing techniques for evaluation of Water penetration in rendered facades - the portable moisture meter and karsten tube”
4. Maldague · 2001
5. “An innovative methodology for the non-destructive diagnosis of architectural elements of ancient historical buildings”10.1038/s41598-018-22601-5 ↗
6. Aplicaciones de la termografía infrarroja y la espectrorradiometría en el estudio del deterioro del patrimonio arquitectónico nacional10.3989/ic.1996.v48.i443.1003 ↗
7. Quantitative infrared thermography in buildings10.1016/S0378-7788(97)00039-X ↗
8. Monitoring of ancient buildings by thermal method10.1016/S1296-2074(02)01159-7 ↗
9. Moisture map by IR thermography10.1080/09500341003731597 ↗
10. A qualitative method for combining thermal imprints to emerging weak points ofancient wall structures by passive infrared thermography – a case study10.1016/j.culher.2013.03.006 ↗
11. Concurrent studies on artworks by digital speckle pattern interferometry and thermographic analysis
12. Multitemporal thermal analysis to detect moisture on a building façade10.1016/j.conbuildmat.2010.10.007 ↗
13. Inspección mediante técnicas no destructivas de un edificio histórico: Oratorio San Felipe Neri (Cádiz)10.3989/ic.10.032 ↗
14. Infrared thermographic inspection of murals and characterization of degradation in historic monuments10.1016/j.conbuildmat.2012.06.062 ↗
15. Using advanced NDT for historic buildings: towards an integrated multidisciplinary health assessment strategy10.1016/j.culher.2014.09.010 ↗
16. Hygrothermal performance evaluation of traditional brick masonryin historic buildings10.1016/j.enbuild.2015.07.049 ↗
17. Termografía infrarroja aplicada en cúpulas históricas: identificación y análisis de sistemas constructivos10.3989/ic.14.133 ↗
18. Measuring of the moisture content in brick walls of historical buildings – the overview of methods, IOP Conf. Series
19. Foulks · 1997
20. Voutilainen · 2005
21. “Moisture measurement in Tirsted Church”10.1080/13556207.2004.10784904 ↗
22. Merikallio · 2002
23. “Multilayer microwave moisture scans at large areas in civil engineering”10.1007/978-94-007-0723-8_113 ↗
24. Application of infrared thermography in complex moisture inspection of the schebek palace. Thermophysics 2017
25. Utrera · 1995 · 369
26. Noticias Históricas de Santo Domingo
27. 1947
28. Ugarte · 1995 · Volume1
29. Flores · 2018
30. 2013
31. Flores Sasso, Virginia · 2001
32. Tpi USA. 1010a, Indoor Air Quality Meter. https://www.testproductsintl.com/indoor-air-quality-iaq-2/indoor-air-quality-iaq-meters/1010a-indoor-air-quality-meter/ [accessed 8th April 2018].
33. Davis Instruments.Vantage Pro2. https://www.davisnet.com/solution/vantage-pro2/ [accessed 2th April 2018].
34. Infrared thermography (IRT) applications for building diagnostics: a review10.1016/j.apenergy.2014.08.005 ↗
35. After the switchgear
36. A pessimistic view of the energy auditing of building structures with the use of infrared thermography10.1134/S1061830910120065 ↗
37. Pleşu · 2012 · 157
38. UNE-EN 13187:1998 / ISO 6781:1983 modified. “Thermal performance of buildings. Qualitative detection of thermal irregularities in building envelopes. Infrared method”.
39. OMEGA. Table of Total Emissivity. https://www.omega.com/temperature/Z/pdf/z088-089.pdf.
40. TRAMEX Meters · 2017
41. 2006
42. Delmhorst Instrument Co · 1999
43. Delmhorst Instrument Co. https://www.delmhorst.com/blog/bid/360520/what-is-a-moisture-meter-reference-scale-and-how-do-i-interpret-it [accessed 27th December 2018].
44. Golden Software. Surfer Version 15. http://www.goldensoftware.com/products/surfer [accessed 15th April 2018].