journal article·2025-12Open access

Compressive behavior of prestressed SFRCFST stub columns after heating: Effect of fresh concrete compression technique

Manouchehr Nemati, Arman Aminian, Sepideh Rahimi, Mahdi Nematzadeh, Mobin Jafarzadeh-Taleshi, Huu-Tai Thai

Abstract

One innovative and effective technique to enhance the compression response of concrete-filled steel tube (CFST) columns is the compression of the fresh concrete, which actively confines the concrete core by prestressed steel tubes. To utilize active confinement in structural design, the behavior of prestressed CFST columns under different conditions should be investigated. In this research, the compression response of steel fiber-reinforced concrete-filled steel tube (SFRCFST) stub columns prestressed by the fresh concrete compression (FCC) technique was assessed before and after experiencing heat. Toward this goal, 60 cylindrical SFRCFST specimens were fabricated, with key variables of the prestressing ratio, volume percentage of steel fibers, applied temperature, external diameter-to-wall thickness ratio (D/t) of steel tube, and water/cement ratio. Post-heating axial compression tests examined the loading capacity, ductility, peak strain, toughness, and load-strain response. It was revealed that due to prestressing and the temperature rise to 600 °C, the heat-induced reduction in load capacity was negligible, while this drop was notable in the specimens without prestressing. At a temperature of 600°C, the load-bearing capacity of the specimens with a prestressing ratio of 0.5 f y increased by 40 % compared to the non-confined specimens, while the axial and lateral strain capacities decreased by 40 and 49 %, respectively. With an increase in the prestressing ratio to 0.7 f y , the load-bearing capacity increased by 50 %, and the axial and lateral strain capacities decreased by 26 and 25 %, respectively. In prestressed and non-prestressed SFRCFST columns, with or without thermal exposure, a steel fiber content of up to 1.5 % improved toughness and increased peak strain and ductility in most specimens. Finally, the nonlinear regression analysis was employed to present a proper prediction model for the loading capacity of SFRCFST columns. • Active confinement by the FCC technique improves SFRCFST axial performance. • Prestressing mitigates heat-induced load capacity reduction up to 600 °C. • Prestressing and steel fiber inclusion enhance SFRCFST thermal behavior. • Steel fiber addition up to 1.5 % increases strength, toughness, and strain capacity. • Validated nonlinear model accurately predicts SFRCFST stub column load capacity.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (73)

Show source-provided references
1. Strength and ductility of stiffened thin-walled hollow steel structural stub columns filled with concrete10.1016/j.tws.2008.01.007 ↗
2. Concrete-filled cold-formed circular steel tubes subjected to variable amplitude cyclic pure bending10.1016/j.engstruct.2007.03.025 ↗
3. Behavior of SSFA high-strength concrete at ambient and after exposure to elevated temperatures
4. A stress-path dependent stress-strain model for FRP-confined concrete10.1016/j.engstruct.2019.109824 ↗
5. Behavior and strength of circular concrete-filled tube columns10.1016/S0143-974X(02)00005-6 ↗
6. A path dependent constitutive model for CFFT column10.1016/j.engstruct.2020.110367 ↗
7. Simplified proposal for the temperature field of steel-reinforced CFST columns exposed to fire10.1016/j.engstruct.2022.115083 ↗
8. Improving the post-fire behaviour of steel slag coarse aggregate concrete by adding GGBFS
9. Flexural strengthening of heat-damaged RC beams with NSM CFRP strips and SFRC layer: Experimental evaluation and theoretical analysis
10. Axial capacity of circular concrete-filled tube columns10.1016/j.jcsr.2003.10.001 ↗
11. Enhancing the post-fire behavior of steel slag normal-strength concrete by adding SCM10.1016/j.conbuildmat.2023.132336 ↗
12. Projectile impact and drop weight resistance of functionally graded fiber-reinforced magnetite aggregate concrete10.1016/j.dt.2025.03.022 ↗
13. A theoretical axial stress-strain model for circular concrete-filled-steel-tube columns10.1016/j.engstruct.2016.06.048 ↗
14. Effect of fillers on the behaviour of low carbon footprint concrete at and after exposure to elevated temperatures
15. FRP-confined circular concrete-filled thin steel tubes under axial compression10.1061/(ASCE)CC.1943-5614.0000217 ↗
16. Packing coupled post-fire behavior of ultra-heavy-weight concrete10.1016/j.conbuildmat.2025.141008 ↗
17. A novel packing-coupled stress-strain model for confined concrete10.1016/j.engstruct.2023.117415 ↗
18. Fire design of steel-reinforced CFST stub columns with high-strength materials10.1016/j.jcsr.2024.108692 ↗
19. Confinement effect of ring-confined concrete-filled-steel-tube columns under uni-axial load10.1016/j.engstruct.2014.02.013 ↗
20. Behaviour of uni-axially loaded concrete-filled-steel-tube columns confined by external rings10.1002/tal.1046 ↗
21. Effect of continuous spirals on uni-axial strength and ductility of CFST columns10.1016/j.jcsr.2014.10.007 ↗
22. Behavior of FRP Ring-Confined CFST columns under axial compression10.1016/j.compstruct.2020.113166 ↗
23. Comprehensive study of eccentrically loaded CFRP-confined RC columns maximum capacity: prediction via ANN and GEP10.1007/s41939-025-00738-x ↗
24. Stress-strain model of an FRP-confined concrete filled steel tube under axial compression10.1016/j.tws.2019.05.009 ↗
25. Mechanical performance of eccentrically loaded pre-stressing concrete filled circular steel tube columns by means of expansive cement10.1016/j.engstruct.2009.06.007 ↗
26. Mechanical performance of self-stressing CFST columns under uniaxial compression
27. Axial compressive behavior of concrete actively confined by metal strips; part A: experimental study10.1617/s11527-010-9588-6 ↗
28. RC columns of square section–passive and active confinement with composite ropes10.1016/j.compositesb.2013.11.011 ↗
29. Active confinement of concrete members with self-stressing composites
30. Experimental investigation of actively confined concrete using shape memory alloys10.1016/j.engstruct.2009.11.012 ↗
31. Experimental study and calculation of confinement relationships for prestressed steel tube-confined compressed concrete stub columns10.3846/13923730.2017.1281837 ↗
32. Nematzadeh · 2012
33. Compressive behaviour of circular steel tube-confined concrete stub columns with active and passive confinement
34. The effect of active and passive confining pressure on compressive behavior of STCC and CFST
35. A review on fire resistance of steel-concrete composite slim-floor beams
36. A novel prediction model for post-fire elastic modulus of circular recycled aggregate concrete-filled steel tubular stub columns
37. Developments and advanced applications of concrete-filled steel tubular (CFST) structures: members10.1016/j.jcsr.2014.04.016 ↗
38. Fire behavior and performance of concrete-filled steel tubular columns: review and discussion10.1016/j.jcsr.2019.02.012 ↗
39. Post-fire performance of axially-loaded elliptical concrete-filled steel tubular stub columns10.1016/j.istruc.2023.02.116 ↗
40. Experimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure10.1016/j.tws.2023.110900 ↗
41. Effects of steel fiber addition on mechanical properties of concrete and RC beams10.1016/j.conbuildmat.2005.12.006 ↗
42. Response of steel fiber-reinforced concrete beams with and without stirrups
43. Evolution of confinement stress in axially loaded concrete-filled steel tube stub columns: study on enhancing urban building efficiency10.3390/su16177544 ↗
44. Experimental study on elastic modulus of steel stub columns encased in RC containing steel fibers
45. An evolutionary approach for predicting the axial load-bearing capacity of concrete-encased steel (CES) columns
46. Axial compressive performance of steel tube columns filled with steel fiber-reinforced high strength concrete containing tire aggregate after exposure to high temperatures10.1016/j.engstruct.2020.110608 ↗
47. Pre-and post-heating behavior of concrete-filled steel tube stub columns containing steel fiber and tire rubber10.1016/j.istruc.2020.07.034 ↗
48. Effect of fresh concrete compression technique on pre- and post-heating compressive behavior of steel fiber-reinforced concrete: Experiments and RSM-based optimization10.1016/j.conbuildmat.2023.132786 ↗
49. ASTM C150/C150M · 2020
50. ASTM D2419 · 2014
51. ASTM C33/C33M · 2018
52. ASTM E8/E8M · 2016
53. ASTM C143/C143M · 2020
54. Pre-and post-heating bar-concrete bond behavior of CFRP-wrapped concrete containing polymeric aggregates and steel fibers: experimental and theoretical study10.1016/j.engstruct.2024.118929 ↗
55. Size effect on CFST-column seismic performances at cryogenic temperature via mesoscale simulations10.1016/j.jcsr.2024.109048 ↗
56. Behaviour of stainless steel bolts after exposure to elevated temperatures10.1016/j.jcsr.2019.02.021 ↗
57. Compressive strength and modulus of elasticity of freshly compressed concrete10.1016/j.conbuildmat.2012.02.055 ↗
58. Residual strength of concrete containing recycled materials after exposure to fire: a review10.1016/j.conbuildmat.2013.04.005 ↗
59. Explosive spalling and residual mechanical properties of fiber-toughened high-performance concrete subjected to high temperatures10.1016/j.cemconres.2005.12.014 ↗
60. Behavior of steel fiber reinforced concrete-filled steel tube columns under axial compression10.1016/j.conbuildmat.2015.07.114 ↗
61. Mechanical behavior of recycled aggregate concrete-filled steel tube stub columns after exposure to elevated temperatures10.1016/j.conbuildmat.2017.04.118 ↗
62. Compressing fresh concrete technique and the effect of excess water content on physical–mechanical properties of compressed concrete10.1016/j.matdes.2011.12.051 ↗
63. Compressive behaviours of CFST stub columns at low temperatures relevant to the Arctic environment10.1016/j.conbuildmat.2019.07.026 ↗
64. ISO 834 · 1999
65. Effect of bond shear stress on compressive behaviour of steel tube-confined concrete with active and passive confinement10.1080/19648189.2016.1219878 ↗
66. Axial compression behavior of hybrid fiber reinforced concrete filled steel tube stub column10.1016/j.conbuildmat.2018.04.089 ↗
67. Effect of temperature on Mode I and Mode II Fracture Toughness of Lushan sandstone
68. Experimental behaviour of stiffened concrete-filled thin-walled hollow steel structural (HSS) stub columns10.1016/j.jcsr.2004.12.003 ↗
69. Experiments on rectangular concrete-filled steel tubes loaded axially on a partially stressed cross-sectional area10.1016/j.jcsr.2009.04.004 ↗
70. Seismic behaviour of circular CFST columns and RC shear wall mixed structures: experiments10.1016/j.jcsr.2009.04.023 ↗
71. Behavior of thin walled steel tube confined concrete stub columns subjected to axial local compression10.1016/j.tws.2007.08.029 ↗
72. Seismic behavior and strength of tubed steel reinforced concrete (SRC) short columns10.1016/j.jcsr.2010.01.020 ↗
73. Analysis of axially loaded concrete filled circular hollow double steel tubular columns exposed to fire10.1016/j.firesaf.2016.12.007 ↗