Thermophysical indicators of elaborated sandwich cladding constructions with heat-reflective coverings and air gaps
Source abstract
Abstract
In this paper, an experimental study of the thermophysical processes occurring in the developed two new structures of external fencing with the use of heat-reflecting screens in comparison with the traditional one is carried out. The results of the study showed that the use of air interlayers and heat-reflecting screens in the design leads to a significant increase in the value of heat transfer resistance by 3.4% in cases with horizontal channels and by 17.7% in the presence of a conventional interlayer with heat-reflecting screens. At the same time, during the experimental studies, it was also found that, unlike the traditional design of the external fence, both models of wall fencing with air layers and heat-reflecting screens developed showed a positive effect in terms of the heat flow value by 52.5% and 51.8%, respectively. Thus, the study experimentally confirmed the effectiveness of the developed new structures of external fencing, and the results of the study can be used in the design and construction of buildings in order to reduce heat consumption and energy saving.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Innovations in Concrete and Construction Materials · Material Properties and Applications · Construction Management and Sustainability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (61)
Show source-provided references
1. Performance and cost analysis of retrofit strategies applied to a sample single family house located in new delhi india assisted by TRNSYS energy simulation tool-a case study
2. The usage of air gap in the composite wall for energy saving and air pollution10.1002/ep.10486 ↗
3. Evaluating the effectiveness of energy-saving retrofit strategies for residential buildings
4. Modeling the thermal regime of a room in a building with a thermal energy storage envelope
5. Construction of a model for an enclosing structure with a heat-accumulating material with phase transition taking into account the process of solar energy accumulation
6. Study of the model of the phase transition envelope taking into account the process of thermal storage under natural draft and by air injection
7. Optimizing insulation thickness for buildings using life cycle cost10.1016/S0306-2619(99)00023-9 ↗
8. DOE: 2011 Building energy data book. Energy efficiency and renewable energy. – US Department of Energy, 2011. https://ieer.org/wp/wp-content/uploads/2012/03/DOE-2011-Buildings-Energy-DataBook-BEDB.pdf (Accessed 25 December 2022).
9. Economically feasible energy refurbishment of prefabricated building in Belgrade, Serbia10.1016/j.enbuild.2014.10.041 ↗
10. Selected aspects of indoor climate in a passive office building with a thermally activated building system: a case study from Poland10.3390/en14040860 ↗
11. eREN energetic refurbishment – a global approach for the building envelope10.1016/j.egypro.2017.07.384 ↗
12. Effective and robust energy retrofitting measures for future climatic conditions – Reduced heating demand of Swedish households10.1016/j.enbuild.2016.03.044 ↗
13. Determining the features of oscillations in prestressed pipelines
14. Experimental research of the stress-strain state of prestressed cylindrical shells taking into account temperature effects
15. Strength analysis of prestressed vertical cylindrical steel oil tanks under operational and dynamic loads
16. Influence of the parameters of the pre-stressed winding on the oscillations of vertical cylindrical steel oil tanks
17. Estimation of the strength of vertical cylindrical liquid storage tanks with dents in the wall
18. Estimating of the stress-strain state of the vertical mounting joint of the cylindrical tank wall taking into account imperfections
19. Analysis of stress-strain state for a cylindrical tank wall defected zone10.3390/ma15165732 ↗
20. Changes in microstructure and properties of austenitic steel aisi 316 during high-pressure torsion
21. Analysis of a stress-strain state of a cylindrical tank wall vertical field joint zone10.3390/buildings12091445 ↗
22. Receiving portland cement from technogenic raw materials of South Kazakhstan10.18321/ectj890 ↗
23. Experimental analysis of the stress state of a prestressed cylindrical shell with various structural parameters10.3390/ma15144996 ↗
24. Analysis of strength and eigenfrequencies of a steel vertical cylindrical tank without liquid, reinforced by a plain composite thread
25. Characterization of a naturally ventilated double-skin façade through the design of experiments (DOE) methodology in a controlled environment10.1016/j.enbuild.2022.112024 ↗
26. Impact of double skin facade constructional features on heat transfer and fluid dynamic behaviour10.1016/j.buildenv.2021.107796 ↗
27. Numerical and experimental study of the dynamic thermal resistance of ventilated air-spaces behind passive and active façades10.1016/j.buildenv.2022.109616 ↗
28. Determining the cost saving and emission reduction of optimum insulation thickness and air gap for building walls
29. Performance of lightweight and heavyweight building walls with naturally ventilated passive and active facades10.1016/j.enbuild.2021.111751 ↗
30. An experimental study of the summer and winter thermal performance of an opaque ventilated facade in cold zone of China10.1016/j.buildenv.2022.109108 ↗
31. Experimental study for the effect of air gap in building walls on heat gain reduction
32. An innovative compact facility for the measurement of the thermal properties of building materials: first experimental results10.1016/j.applthermaleng.2018.06.023 ↗
33. Environmentally friendly opaque ventilated façade for wall retrofit: one year of in-field analysis in Mediterranean climate10.1016/j.solener.2021.09.063 ↗
34. Effect of different building façade systems on thermal comfort and urban heat island phenomenon: an experimental analysis10.1016/j.buildenv.2022.109063 ↗
35. Reflective thermal insulation in non-ventilated air-gaps: experimental and theoretical evaluations on the global heat transfer coefficient10.1016/j.enbuild.2021.110769 ↗
36. The role of wall layers properties on the thermal performance of ventilated facades: Experimental investigation on narrow-cavity design
37. Experimental evaluation of ventilated walls with an external clay cladding10.1016/j.renene.2011.05.016 ↗
38. Experimental study on the thermal performance of ventilation wall with cladding panels in hot and humid area10.1016/j.proeng.2015.08.1086 ↗
39. Experimental studies of the effect of air flow in the gap on the heat-shielding properties of ventilated facade systems
40. Hinged ventilated facades: problems of the state of standards and questions of the use of some materials
41. Design features of a ventilated facade with foam glass insulation
42. Experimental study of moisture transfer in a heat-insulating panel with ventilated channels
43. The expediency of choosing the type of heat-insulating material and scaffolding used in the construction of a ventilated facade system during the construction of an apartment building
44. Analysis of thermal resistance of developed energy-saving external enclosing structures with air gaps and horizontal channels10.3390/buildings13020356 ↗
45. Analysis of the heat-insulating material volume influence on thermal resistance of the developed facade structures with closed horizontal air channels
46. Sanitary Standards of the Republic of Kazakhstan 2.04–04-2011 Thermal Protection of Buildings: State Standards in the Field of Architecture, Urban Planning and Construction. Code of Rules of the Republic of Kazakhstan. – JSC “KazNIISA”, LLP “Astana Stroy-Consulting”, 2013. Approved and Enacted on 1 July 2015. 14 p. https://hoffmann.kz/files/12_SN_RK_2–04-04–2011.pdf (Accessed 20 April 2023).
47. Sanitary Regulations of the Republic of Kazakhstan 2.04–106-2012 Design of Thermal Protection of Buildings: State Standards in the Field of Architecture, Urban Planning and Construction. Code of Rules of the Republic of Kazakhstan. – JSC “KazNIISA”, LLP “Astana Stroy-Consulting”, 2013. Approved and Enacted on 1 July 2015. 74 p. https://online.zakon.kz/Document/?doc_id=35957424 (Accessed 20 April 2023).
48. Code of Rules of the Republic of Kazakhstan 2.04–01-2017 Building Climatology: State Standards in the Field of Architecture, Urban Planning and Construction. Code of Rules of the Republic of Kazakhstan. – JSC “KazNIISA”, LLP “Astana Stroy-Consulting”, 2017. Approved and Enacted on 20 December 2017. 43 p. Available online: https://online.zakon.kz/m/document/?doc_id=37599018 (Accessed 20 April 2023).
49. GOST 25380–2014 Building and constructions. Method for measuring the density of heat currents passing through building envelopes. 2015, 12 p. https://ohranatruda.ru/upload/iblock/907/4293768337.pdf (Accessed 23 April 2023).
50. GOST 7076–99 Building materials and products. Method for defining thermal conductivity and thermal resistance under stationary thermal conditions. 2000, 10 p. https://perm.ekover.ru/uploadedFiles/files/GOST_7076–99.pdf (Accessed 23 April 2023).
51. Brodach M.M.. VIIKKI – a new look at energy saving // AVOK: ventilation, heating, air conditioning, heat supply and building thermal physics. 2002. 6. 14–20. https://www.abok.ru/for_spec/articles.php?nid=1840 (Accessed 15 April 2023).
52. Code of Rules of the Republic of Kazakhstan 2.04–107-2013 Building Heat Engineering: State Standards in the Field of Architecture, Urban Planning and Construction. Code of Rules of the Republic of Kazakhstan. – JSC “KazNIISA”, LLP “Astana Stroy-Consulting”, 2013. Approved and Enacted on 1 July 2015. 80 p. Available online: https://online.zakon.kz/m/document/?doc_id=37599018 (Accessed 20 April 2023).
53. Hardening of bimetallic wires from secondary materials used in the construction of power lines10.3390/ma15113975 ↗
54. Technological perspective for use the natural pineapple fiber in mortar to repair structures10.1007/s12649-021-01374-5 ↗
55. Acoustic properties of innovative concretes: a review10.3390/ma14020398 ↗
56. Impact performance of steel fiber-reinforced self compacting concrete against repeated drop weight impact10.3390/cryst11020091 ↗
57. Rice husk ash‐based concrete composites: a critical review of their properties and applications10.3390/cryst11020168 ↗
58. High-strength fibrous concrete of Russian Far East natural materials
59. Self-compacting concrete using pretreatmented rice husk ash
60. Fine-grained concrete of composite binder
61. Mechanical properties of fiber-reinforced concrete using composite binders10.1155/2017/2316347 ↗