journal article·2023-07Open access

Shear behavior of externally prestressed UHPC beams without stirrups

Jiahui Feng, Peisen Li, Jinpeng Wu, Haibo Jiang, Yueqiang Tian, Xiangdong Sun

Abstract

Shear stirrups in a prestressed ultra-high performance concrete (UHPC) beam might be eliminated due to the high tensile strength of UHPC. This research aims to investigate shear behavior of the externally prestressed UHPC beams without stirrups. Thirteen UHPC beams were tested with the experimental parameters of prestressing level, shear span-to-depth ratio, longitudinal reinforcement ratio, fiber content, and stirrup ratio. The results showed that the beam with the longitudinal reinforcement ratio of 2.0% under a shear span-to-depth ratio of 2.0 failed in flexure, even though additionally applying a higher prestressing up to 40% of tensile strength of prestressing tendon. However, the externally prestressed UHPC beams under a shear span-to-depth ratio lower than 2.0 failed in shear. The shear strength of UHPC beam increased with a higher prestressing, lower shear span-to-depth ratio, more longitudinal reinforcements and stirrups, and higher fiber content. French Standard formula and PCI formula for shear design were conservative, irrespective of the existence or absence of stirrups in the prestressed UHPC beam. The calculated results indicated that the externally prestressed UHPC beams met the requirement of shear design codes when no stirrup was employed.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Design guide for precast UHPC waffle deck panel system, including connections, No. FHWA-HIF-13-032. United States
2. Ultrahigh-performance concrete segmental bridge technology: toward sustainable bridge construction
3. Static behavior of grouped stud shear connectors in steel-precast UHPC composite structures containing thin full-depth slabs10.1016/j.engstruct.2021.113484 ↗
4. Interfacial shear and flexural performances of steel-precast UHPC composite beams: full-depth slabs with studs vs. demountable slabs with bolts10.1016/j.engstruct.2022.114230 ↗
5. Experimental investigation on shear behavior of high-strength friction-grip bolt shear connectors in steel-precast UHPC composite structures subjected to static loading10.1016/j.engstruct.2021.112777 ↗
6. Finite element analysis of shear performance of UHPFRC-encased steel composite beams: parametric study10.1016/j.engstruct.2022.114940 ↗
7. M.A. Sakr, A.A. Sleemah, T.M. Khalifa, W.N. Mansour, Behavior of RC beams strengthened in shear with ultra-high performance fiber reinforced concrete (UHPFRC), MATEC Web of Conferences, 199, (2018). doi.org/10.1051/matecconf/201819909002.10.1051/matecconf/201819909002 ↗
8. Flexural strengthening of RC one way solid slab with strain hardening cementitious composites (SHCC)
9. Vertical cracking at girder ends during posttensioning of prefabricated prestress concrete bridge T-girders10.1002/suco.202100004 ↗
10. Novel FRP interlocking multi-spiral reinforced-seawater sea-sand concrete square columns with longitudinal hybrid FRP–steel bars: monotonic and cyclic axial compressive behaviours
11. Lateral hysteretic behavior of a novel metal rubber bridge bearing10.1016/j.engstruct.2022.114051 ↗
12. Shear behavior of RC pile cap beams strengthened using ultra-high performance concrete reinforced with steel mesh fabric
13. Seismic performance of a novel RC partial precast shear wall with reserved cast-in-place base and wall edges10.1016/j.soildyn.2021.107038 ↗
14. Shear database for reinforced concrete members without shear reinforcement
15. Where is shear reinforcement required? review of research results and design procedures
16. Shear strength of steel fiber-reinforced ultrahigh-performance concrete beams without stirrups10.1061/(ASCE)ST.1943-541X.0000234 ↗
17. Flexural and shear behaviors of reinforced ultrahigh toughness cementitious composite beams without web reinforcement under concentrated load10.1016/j.engstruct.2012.01.011 ↗
18. Experimental investigations of failure modes of reinforced concrete beams without web reinforcement10.1016/j.engstruct.2019.01.102 ↗
19. Experimental analysis of the shear strength of composite concrete beams without web reinforcement
20. Ultimate strength in shear of simply-supported prestressed concrete beams without web reinforcement
21. Shear strength of fiber-reinforced high-strength steel ultra-high-performance concrete beams based on refined calculation of compression zone depth considering concrete tension10.1177/1369433219829805 ↗
22. Experimental study on shear performances of ultra-high performance concrete deep beams10.1016/j.istruc.2022.03.019 ↗
23. Influence of fiber properties on shear failure of steel fiber reinforced beams without web reinforcement: ANN modeling10.1590/1679-78252851 ↗
24. Shear behavior of ultra-high-performance concrete beams reinforced with high-strength steel bars
25. Shear behavior of fiber-reinforced ultra-high performance concrete beams10.1016/j.engstruct.2018.04.075 ↗
26. Shear behaviour of ultra-high performance concrete beams with openings10.1016/j.istruc.2022.06.071 ↗
27. Shear strength of eco-friendly self-compacting concrete beams containing ground granulated blast furnace slag and fly ash as cement replacement
28. Shear strength of UHPFRC beams: mesoscale fiber-matrix discrete model
29. Shear carrying capacity of ultra-high performance concrete beams
30. Shear behavior of pretensioned high strength concrete bridge I-girders
31. Optimization method and experimental study on the shear strength of externally prestressed concrete beams10.1260/1369-4332.17.4.607 ↗
32. Experimental study on shear behavior of precast high-strength concrete segmental beams with external tendons and dry joints10.3390/buildings12020134 ↗
33. Shear stress contributions and failure mechanisms of high strengh reinforced concrete beams10.1007/BF02479437 ↗
34. Dowel action and shear strength contribution of high strength rebar embedded in ultra-high performance fiber reinforced concrete10.1016/j.engstruct.2014.11.004 ↗
35. Shear failure of patched reinforced concrete beam without web reinforcements10.4028/www.scientific.net/KEM.737.441 ↗
36. B. Graybeal, Structural behavior of ultra-high performance concrete prestressed I-girders, Federal Highway Administration, U.S. Department of Transportation, Report No. FHWA-HRT-06–115, McLean, VA, 2006.
37. Shear strength of fiber reinforced reactive powder concrete prestressed girders without stirrups10.3151/jact.4.123 ↗
38. F. Baby, J. Billo, J. Renaud, C. Massotte, P. Marchand, F. Toutlemonde, A. Simon, P. Lussou, Shear resistance of ultra high performance fibre reinforced concrete I beams, Proceedings of the 7th International Conference on Fracture Mechanics of Concrete and Concrete Structures, Korea, May 2010, pp. 1411–1417.
39. French standard (NF P18–470), Concrete - ultra-high performance fibre-reinforced concrete - Specifications, performance, production and conformity, 2016.
40. French standard (NF P18–710), National addition to Eurocode 2 - Design of concrete structures: specific rules for ultra-high performance fibre-reinforced concrete (UHPFRC), 2016.
41. M. Tadros, J. Lawler, M.A. El-Khier, D. Gee, A. Kurt, G. Lucier,E. Wagner, Implementation of ultra-high-performance concrete in long-span precast pretensioned elements for concrete buildings and bridges, Precast/Prestressed Concrete Institute (PCI), Phase II Report, 2021.
42. Axial tensile behavior test of ultra high performance concrete
43. Experimental study on shear behavior of precast concrete segmental beams with hybrid tendons and dry joints10.1007/s12205-019-1229-1 ↗
44. Shear behavior of precast concrete segmental beams with external tendons10.1061/(ASCE)BE.1943-5592.0001249 ↗