journal article·2021-12-31

Experimental Research on Self-repairing of Diverging Stepped Magnetic Fluid Seals with Single Magnetic Source

Xiaolong Yang, Yuting Liu, Ruibo Zhang, Shanghan Gao

Journal of Magnetics· Volume 26· Issue 4
Publisher page

Abstract

To improve the self-repairing capability of common magnetic fluid seal structures after rupture due to excessive differential pressure in small clearance conditions and to verify the superiority of diverging stepped magnetic fluid seals, a diverging stepped magnetic fluid seal device with single magnetic source was tested. The effect of injection volume, clearance and numbers of teeth on the self-repairing performance of a diverging stepped magnetic fluid seals was investigated experimentally and compared with a common magnetic fluid seal. The experimental results indicate that the self-repairing performance of one stepped magnetic fluid seal device is better. The repair rate of a diverging stepped magnetic fluid seal structure decreases first and then increases with the increase of injection volume, and a minimum value is reached near the saturation value. The smaller the sealing gap and the fewer the number of bore teeth, the higher the repair rate of this structure.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Characterization and Applications of Magnetic Nanoparticles · Geomagnetism and Paleomagnetism Studies · Tribology and Lubrication Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.