Abstract

Traditional piles used for deep foundation, such as steel, concrete, and timber, are susceptible to corrosion and a reduction in structural capacity over time. This has led to the development of new materials like concrete-filled FRP piles (CFFP). CFFP is a composite pile filled with concrete and covered with a fiber-reinforced plastic (FRP) shell, providing non-corrosive reinforcement and protection to the concrete. As a result, CFFP is a highly promising candidate for implementation in various fields due to its structural advantages and necessity. Compared to traditional concrete piles, CFFP can be installed with less damage and a lower blow range due to its elastic modulus, damping ratio, and specific weight. The bearing capacity of a pile is influenced by various factors, including its stiffness, residual stress, and axial load resistance. Due to competitive pricing, glass fiber has been widely utilized, and there is a growing interest regarding carbon-fiber-reinforced concrete piles due to the excellent mechanical properties of carbon fiber. The remarkable stiffness and strength attributes of carbon fibers are evident in CFRP-confined piles, which present a notably wide range of load-bearing capacities, boasting an ultimate axial load capacity ranging from 500 to 4000 kN. Furthermore, CFFPs have been confirmed to have superior lateral load resistance compared to conventional piles, attributed to the reinforcement provided by FRP materials. Conventional piles face a challenge in that their structural characteristics deteriorate in the corrosive marine environment, with a projected lifespan of less than 20 years. In contrast, the service life of CFFPs is estimated to range from 50 to 75 years.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Mechanical stress and fatigue analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (94)

Show source-provided references
1. Manap N, Tan K, Syahrom N (eds) (2017) Main issues of pile foundation at waterfront development and its prevention method. IOP conference series: earth and environmental science: IOP Publishing10.1088/1755-1315/109/1/012026 ↗
2. Manap N, Voulvoulis N (2016) Data analysis for environmental impact of dredging. J Clean Prod 137:394–40410.1016/j.jclepro.2016.07.109 ↗
3. Guades E, Aravinthan T, Islam M, Manalo A (2012) A review on the driving performance of FRP composite piles. Compos Struct 94:1932–194210.1016/j.compstruct.2012.02.004 ↗
4. Iskander MG, Hanna S, Stachula A (2001) Driveability of FRP composite piling. J Geotechn Geoenviron Eng 127:169–17610.1061/(ASCE)1090-0241(2001)127:2(169) ↗
5. Daniel IM, Ishai O, Daniel IM, Daniel I (2006) Engineering mechanics of composite materials. Oxford University Press, New York
6. Shaia H (2013) Behaviour of fibre reinforced polymer composite piles: experimental and numerical study. The University of Manchester, London
7. Helmi K, Fam A, Mufti A (2006) Behavior of concrete filled FRP tubes under fully reversed cyclic bending. Arab J Sci Eng 31:215
8. Ozbakkaloglu T, Xie T (2016) Geopolymer concrete-filled FRP tubes: behavior of circular and square columns under axial compression. Compos B Eng 96:215–23010.1016/j.compositesb.2016.04.013 ↗
9. Iskander MG, Hassan M (1998) State of the practice review in FRP composite piling. J Compos Constr 2:116–12010.1061/(ASCE)1090-0268(1998)2:3(116) ↗
10. Sakr M, El Naggar M, Nehdi M (2005) Interface characteristics and laboratory constructability tests of novel fiber-reinforced polymer/concrete piles. J Compos Constr 9:274–28310.1061/(ASCE)1090-0268(2005)9:3(274) ↗
11. Lee H, Kang BH, Lee SH (2020) Foundation methods for the soft ground reinforcement of lightweight greenhouse on reclaimed land: a review. Protected Hortic Plant Factory 29:440–44710.12791/KSBEC.2020.29.4.440 ↗
12. Lee H, Kang BH, Lee K-s, Lee SH (2021) Estimation of allowable bearing capacity and settlement of deep cement mixing method for reinforcing the greenhouse foundation on reclaimed land. J Bio-Environ Control 30:287–29410.12791/KSBEC.2021.30.4.287 ↗
13. Mirmiran A, Shahawy M (1996) A new concrete-filled hollow FRP composite column. Compos B Eng 27:263–26810.1016/1359-8368(95)00019-4 ↗
14. Fam AZ, Rizkalla SH (2001) Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes. Struct J 98:451–461
15. Juran I, Komornik U (2006) Behavior of fiber-reinforced polymer (frp) composite piles under vertical loads
16. Lampo R, Nosker T, Bamo D, Busel J, Maher A (1998) Development and demonstration of FRP composite fender loadbearing, and sheet piling systems. Construction engineering research lab (army) Champaign IL
17. Fleming K, Weltman A, Randolph M, Elson K (2008) Piling engineering. CRC Press, New York10.1201/b22272 ↗
18. Pando MA, Ealy CD, Filz GM, Lesko J, Hoppe E (2006) A laboratory and field study of composite piles for bridge substructures. United States. Federal Highway Administration. Office of Infrastructure….
19. Juran I, Komornik U (2006) Behavior of fiber-reinforced polymer composite piles under vertical loads. United States. Federal Highway Administration. Office of Infrastructure….
20. Mirmiran A, Shao Y, Shahawy M (2002) Analysis and field tests on the performance of composite tubes under pile driving impact. Compos Struct 55:127–13510.1016/S0263-8223(01)00140-4 ↗
21. Guades E, Aravinthan T, Islam M (eds) (2010) An overview on the application of FRP composites in piling system. In: Proceedings of the Southern Region Engineering Conference (SREC 2010). Engineers Australia.
22. Fam A, Pando M, Filz G, Rizkalla S (2003) Precast piles for Route 40 bridge in Virginia using concrete filled FRP tubes. PCI J 48:32–4510.15554/pcij.05012003.32.45 ↗
23. Baxter CD, Marinucci A, Bradshaw AS, Morgan RJ (2005) Field study of composite piles in the marine environment
24. Fam AZ, Rizkalla SH (2002) Flexural behavior of concrete-filled fiber-reinforced polymer circular tubes. J Compos Constr 6:123–13210.1061/(ASCE)1090-0268(2002)6:2(123) ↗
25. Guo Y-C, Da Liang S, Xiao S-H, Zeng J-J, Sun Y (2020) Behavior of FRP-confined sea-sand concrete columns with a prefabricated concrete-filled FRP-steel core. Compos Part C Open Access 2:10004210.1016/j.jcomc.2020.100042 ↗
26. Cai J, Hao H, Ozbakkaloglu T, Zhang Y, Pan J (2020) Behavior of geopolymeric recycled aggregate concrete-filled FRP tube (GRACFFT) columns under lateral cyclic loading. Eng Struct 222:11104710.1016/j.engstruct.2020.111047 ↗
27. Wang W, Sheikh MN, Hadi MN, Gao D, Chen G (2017) Behaviour of concrete-encased concrete-filled FRP tube (CCFT) columns under axial compression. Eng Struct 147:256–26810.1016/j.engstruct.2017.05.061 ↗
28. Wang W, Sheikh MN, Hadi MN (2015) Confining concrete cover of GFRP tube reinforced concrete columns with polymer grids
29. Hussein MH, Woerner I, Wayne A, Sharp M, Hwang C (2006) Pile driveability and bearing capacity in high-rebound soils. GeoCongress 2006: geotechnical engineering in the information technology age, pp. 1–410.1061/40803(187)63 ↗
30. Iskander MG, Hanna S, Stachula A (2001) Driveability of FRP composite piling. J Geotech Geoenviron Eng 127:169–17610.1061/(ASCE)1090-0241(2001)127:2(169) ↗
31. Stachula A (1999) Drivability of FRP composite piling. Polytechnic University
32. Zyka K, Mohajerani A (2016) Composite piles: a review. Constr Build Mater 107:394–41010.1016/j.conbuildmat.2016.01.013 ↗
33. Na YS, Lee SD (2019) Experimental study on the end bearing capacity of the pile in a group pile
34. Meyerhof GG (1976) Bearing capacity and settlement of pile foundations. J Geotech Eng Div 102:197–22810.1061/AJGEB6.0000243 ↗
35. Vesic AB (1963) Bearing capacity of deep foundations in sand. Highway research record
36. Tao Z, Han L-H, Zhuang J-P (2007) Axial loading behavior of CFRP strengthened concrete-filled steel tubular stub columns. Adv Struct Eng 10:37–4610.1260/136943307780150814 ↗
37. Han L-H, Yao G-H, Zhao X-L (2004) Behavior and calculation on concrete-filled steel CHS (Circular Hollow Section) beam-columns. Steel Compos Struct Int J 4:169–18810.12989/scs.2004.4.3.169 ↗
38. Yu Q (2002) Behaviors of FRP-confined concrete columns. Unpublished doctoral dissertation, Harbin Institute of Technology (in Chinese)
39. Ozbakkaloglu T (2013) Behavior of square and rectangular ultra high-strength concrete-filled FRP tubes under axial compression. Compos B Eng 54:97–11110.1016/j.compositesb.2013.05.007 ↗
40. Fam AZYH (2000) Concrete-filled fibre-reinforced polymer tubes for axial and flexural structural members
41. Moran DA, Pantelides CP (2002) Stress-strain model for fiber-reinforced polymer-confined concrete. J Compos Constr 6:233–24010.1061/(ASCE)1090-0268(2002)6:4(233) ↗
42. Becque J, Patnaik AK, Rizkalla SH (2003) Analytical models for concrete confined with FRP tubes. J Compos Constr 7:31–3810.1061/(ASCE)1090-0268(2003)7:1(31) ↗
43. Youssef MN, Feng MQ, Mosallam AS (2007) Stress–strain model for concrete confined by FRP composites. Compos B Eng 38:614–62810.1016/j.compositesb.2006.07.020 ↗
44. Lee C-S, Hegemier GA (2009) Model of FRP-confined concrete cylinders in axial compression. J Compos Constr 13:442–45410.1061/(ASCE)CC.1943-5614.0000029 ↗
45. Teng J, Hu Y (eds) (2006) Theoretical model for FRP-confined circular concrete-filled steel tubes under axial compression. In: International Conference on FRP Composites in Civil Engineering [CICE]
46. Yu T, Hu Y, Teng J-G (2014) FRP-confined circular concrete-filled steel tubular columns under cyclic axial compression. J Constr Steel Res 94:33–4810.1016/j.jcsr.2013.11.003 ↗
47. Sun G, Zhao Y, Gu W (2008) Stability of concrete filled CFRP-steel tube under axial compression. In: Tubular Structures XII: Proceedings of Tubular Structures XII, Shanghai, China, 8–10 October 2008:111.10.1201/9780203882818.ch12 ↗
48. Choi K-K (2007) Analytical and experimental studies on mechanical behavior of confined concrete filled tubular columns. University of Southern California
49. Abdalla S, Abed F, AlHamaydeh M (2013) Behavior of CFSTs and CCFSTs under quasi-static axial compression. J Constr Steel Res 90:235–24410.1016/j.jcsr.2013.08.007 ↗
50. Hu Y, Yu T, Teng J (2011) FRP-confined circular concrete-filled thin steel tubes under axial compression. J Compos Constr 15:850–86010.1061/(ASCE)CC.1943-5614.0000217 ↗
51. Xiao Y, He W, Choi K-k (2005) Confined concrete-filled tubular columns. J Struct Eng 131:488–49710.1061/(ASCE)0733-9445(2005)131:3(488) ↗
52. Park J-W, Hong Y-K, Hong G-S, Choi S-M (2009) Experimental study on concrete steel circular tubes confined by carbon fiber sheet under axial compression loads. J Earthq Eng Soc Korea 13:61–7110.5000/EESK.2009.13.5.061 ↗
53. Hu Y (2010) Behaviour and modelling of FRP-confined hollow and concrete-filled steel tubular columns
54. Liu L, Lu Y (2010) Axial bearing capacity of short FRP confined concrete-filled steel tubular columns. J Wuhan Univ Technol Mater Sci Ed 25:454–45810.1007/s11595-010-0022-2 ↗
55. Lu Y, Li N, Li S (2014) Behavior of FRP-confined concrete-filled steel tube columns. Polymers 6:1333–134910.3390/polym6051333 ↗
56. Wei Y, Wu G, Li G (2014) Performance of circular concrete-filled fiber-reinforced polymer-steel composite tube columns under axial compression. J Reinf Plast Compos 33:1911–192810.1177/0731684414550836 ↗
57. Park J, Hong Y, Hong G, Kim J, Choi S (2011) Design formulas of concrete filled circular steel tubes reinforced by carbon fiber reinforced plastic sheets. Procedia Eng 14:2916–292210.1016/j.proeng.2011.07.367 ↗
58. Realfonzo R, Napoli A (2011) Concrete confined by FRP systems: confinement efficiency and design strength models. Compos B Eng 42:736–75510.1016/j.compositesb.2011.01.028 ↗
59. Innovations DHT (1995) Federal Highway Administration
60. Davisson M (1972) High capacity piles. Proc Innovations in Found Const 52
61. Poulos HG, Davis EH (1980) Pile foundation analysis and design. Wiley, New York
62. Karthigeyan S, Ramakrishna V, Rajagopal K (2006) Influence of vertical load on the lateral response of piles in sand. Comput Geotech 33:121–13110.1016/j.compgeo.2005.12.002 ↗
63. Japan OCADIo (2002) Technical standards and commentaries for port and harbour facilities in Japan: OCDI
64. Popescu AM, Salman N, Kemp AH (2013) Geographic routing resilient to location errors. IEEE Wirel Commun Lett 2:203–20610.1109/WCL.2013.011713.120849 ↗
65. Wong DO (1991) Subgrade modulus of laterally loaded piles in clays. Transportation Research Record, pp 67–78.
66. Han J (1997) An experimental and analytical study of the behavior of fiber-reinforced polymer piles and pile-sand interactions. Georgia Institute of Technology
67. Han J, Frost JD, Brown VL (2003) Design of fiber-reinforced polymer composite piles under vertical and lateral loads. Transp Res Rec 1849:71–8010.3141/1849-09 ↗
68. Mirmiran A, Shahawy M, El Khoury C, Naguib W (2000) Large beam-column tests on concrete-filled composite tubes. Struct J 97:268–276
69. AASHTO 2nd L (1998) Bridge design specifications. American association of state highway and transportation officials, Washington, DC
70. Officials T (2002) Standard specifications for highway bridges. Aashto
71. Manual CFE (2006) Canadian Geotechnical Society. BiTech Publisher Ltd., Richmond
72. O’Neill M, Reese L (1999) Drilled shafts: construction procedures and design methods publication no. FHWA-IF-99-025. Department of Transportation, Washington DC, USA
73. Sebaey TA (2019) Design of oil and gas composite pipes for energy production. Energy Procedia 162:146–15510.1016/j.egypro.2019.04.016 ↗
74. Pandian A, Sultan MT, Marimuthu U, Shah AU (2020) Low velocity impact studies on fibre-reinforced polymer composites and their hybrids–review10.1016/B978-0-12-803581-8.11289-5 ↗
75. Eslami S, Honarbakhsh-Raouf A, Eslami S (2015) Effects of moisture absorption on degradation of E-glass fiber reinforced Vinyl Ester composite pipes and modelling of transient moisture diffusion using finite element analysis. Corros Sci 90:168–17510.1016/j.corsci.2014.10.009 ↗
76. Xu D, Lu B, Cao T, Zhang H, Chen J, Long H et al (2016) Enhancement of process capabilities in electrically-assisted double sided incremental forming. Mater Des 92:268–28010.1016/j.matdes.2015.12.009 ↗
77. Amaro A, Reis P, Neto M, Louro C (2013) Effects of alkaline and acid solutions on glass/epoxy composites. Polym Degrad Stab 98:853–86210.1016/j.polymdegradstab.2012.12.029 ↗
78. Stamenović M, Putić S, Rakin M, Medjo B, Čikara D (2011) Effect of alkaline and acidic solutions on the tensile properties of glass–polyester pipes. Mater Des 32:2456–246110.1016/j.matdes.2010.11.023 ↗
79. Martins LA, Bastian FL, Netto TA (2012) Structural and functional failure pressure of filament wound composite tubes. Mater Des 1980–2015(36):779–78710.1016/j.matdes.2011.11.029 ↗
80. Onder A, Sayman O, Dogan T, Tarakcioglu N (2009) Burst failure load of composite pressure vessels. Compos Struct 89:159–16610.1016/j.compstruct.2008.06.021 ↗
81. Prabhakar MM, Rajini N, Ayrilmis N, Mayandi K, Siengchin S, Senthilkumar K et al (2019) An overview of burst, buckling, durability and corrosion analysis of lightweight FRP composite pipes and their applicability. Compos Struct 230:11141910.1016/j.compstruct.2019.111419 ↗
82. Pando M, Lesko J, Fam A, Rizkalla S (eds) (2002) Durability of concrete-filled tubular FRP piles. In: The 3rd international conference on composites in infrastructure, ICCI
83. McBagonluri F, Garcia K, Hayes M, Verghese K, Lesko J (2000) Characterization of fatigue and combined environment on durability performance of glass/vinyl ester composite for infrastructure applications. Int J Fatigue 22:53–6410.1016/S0142-1123(99)00100-0 ↗
84. Schultheisz CR, McDonough WG, Kondagunta S, Schutte CL, Macturk KS, McAuliffe M et al (1997) Effect of moisture on E-glass/epoxy interfacial and fiber strengths. ASTM Spec Tech Publ 1242:257–286
85. Fitriah S, Majid MA, Ridzuan M, Daud R, Gibson A, Assaleh T (2017) Influence of hydrothermal ageing on the compressive behaviour of glass fibre/epoxy composite pipes. Compos Struct 159:350–36010.1016/j.compstruct.2016.09.078 ↗
86. El-Hassan H, El-Maaddawy T, Al-Sallamin A, Al-Saidy A (2018) Durability of glass fiber-reinforced polymer bars conditioned in moist seawater-contaminated concrete under sustained load. Constr Build Mater 175:1–1310.1016/j.conbuildmat.2018.04.107 ↗
87. Yin P, He W, Yang ZJ (2018) A simplified nonlinear method for a laterally loaded pile in sloping ground. Advances in Civil Engineering 201810.1155/2018/5438618 ↗
88. Robert M, Benmokrane B (2013) Combined effects of saline solution and moist concrete on long-term durability of GFRP reinforcing bars. Constr Build Mater 38:274–28410.1016/j.conbuildmat.2012.08.021 ↗
89. Wang Z, Zhao X-L, Xian G, Wu G, Raman RS, Al-Saadi S et al (2017) Long-term durability of basalt-and glass-fibre reinforced polymer (BFRP/GFRP) bars in seawater and sea sand concrete environment. Constr Build Mater 139:467–48910.1016/j.conbuildmat.2017.02.038 ↗
90. Zhou L, Guo S, Zhang Z, Shi C, Jin Z, Zhu D (2021) Mechanical behavior and durability of coral aggregate concrete and bonding performance with fiber-reinforced polymer (FRP) bars: A critical review. J Clean Prod 289:12565210.1016/j.jclepro.2020.125652 ↗
91. Wang Z, Zhao X-L, Xian G, Wu G, Raman RS, Al-Saadi S (2017) Durability study on interlaminar shear behaviour of basalt-, glass-and carbon-fibre reinforced polymer (B/G/CFRP) bars in seawater sea sand concrete environment. Constr Build Mater 156:985–100410.1016/j.conbuildmat.2017.09.045 ↗
92. Bazli M, Bazli L, Rahmani R, Mansoor S, Ahmadi M, Pouriamanesh R (2020) Concrete filled FRP–PVC tubular columns used in the construction sector: a review. J Compos Compounds 2:155–16210.29252/jcc.2.3.7 ↗
93. Fam A, Greene R, Rizkalla S (2003) Field applications of concrete-filled FRP tubes for marine piles. Special Publication 215:161–180
94. Lawrence D, Lopez-Anido R, Sandford T, Goslin K, Rofes X (2014) Experimental evaluation and design of unfilled and concrete-filled FRP composite piles, task 3-FRP composite pile flexural testing. Maine. Department of Transportation