Comparison of Spin Seebeck Signal in Y₃Fe5O12 Film Measured by Joule Heating- and Laser Heating-based Measurement Systems
Source abstract
Abstract
In this study, spin Seebeck effect (SSE) signals caused by a thermal gradient induced by Joule and laser heating were examined. A Pt/Y₃FeSUB5/SUBOSUB12/SUB/Gd₃GaSUB5/SUBOSUB12/SUB sample was used as the reference for SSE measurement. Both the Joule heating- and laser heating-based SSE measurement systems captured SSE hysteresis loops consistent with the magnetic hysteresis loop of the sample. The laser heating-based system measured a higher SSE signal; however, heat flux could not be precisely evaluated. With the Joule heating-based system, the spin Seebeck resistivity (SSR) was 21.2 ± 1 nm/A, comparable with the values obtained in other studies and indicating the feasibility of our apparatus for investigating SSE.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Magnetic properties of thin films · Magnetic Properties and Applications · Magneto-Optical Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.