journal article·2013-05-01

Random testing reveals excessive power in commercial laser pointers

Joshua Hadler, Edna Tobares, Marla Dowell

Journal of Laser Applications· Volume 25· Issue 3
Publisher page

Abstract

In random testing of 122 commercial laser pointers, the authors observed that 90% of green pointers and 44% of red pointers were not in compliance with the Code of Federal Regulations (CFR), producing laser power in excess of the CFR-allowed limit at one or more laser wavelengths. The measurement results are presented and the authors describe the inexpensive test bed they used. Also, they suggest physical mechanisms that could account for the hazardous levels of laser pointer emissions.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular and Laser Science Research · Advanced Optical Sensing Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Quantum Electronics and Photonics Division, NIST , Boulder, Colorado 80305

Office of Safety, Health and Environment, NIST , Gaithersburg, Maryland 20899

References (10)

Show source-provided references
1. 2007
2. Important information for laser pointer manufacturers
3. Accurate, inexpensive testing of laser pointer power for safe operation10.1088/0957-0233/24/4/045202 ↗
4. Optical tunnel-trap detector for radiometric measurements10.1088/0026-1394/37/5/29 ↗
5. 2007 · 250
6. Advances in red VCSEL technology
7. The underrated hazard potential of laser pointers
8. Lasers rise as threat to retinas
9. Retinal injuries from a handheld laser pointer10.1056/NEJMc1005818 ↗
10. Maculopathy from handheld green diode laser pointer10.1136/bmj.c2982 ↗