Reinforcement corrosion assessment capability of surface bonded and embedded piezo sensors for reinforced concrete structures

Visalakshi Talakokula, Suresh Bhalla

Publisher page

Abstract

Rebar corrosion has become a very common cause of degradation in the reinforced concrete structures. It is most frequently the result of the chloride-induced breakdown of the passive film formed in the highly alkaline environment. This article presents a comparison of the sensing capabilities of surface bonded and embedded piezoceramic (lead zirconate titanate) patches in diagnosing chloride-induced corrosion for reinforced concrete structures. Experiments are conducted with lead zirconate titanate patches surface bonded on rebar as well as embedded in the vicinity of the rebar inside concrete to compare the sensitivity of the two. Accelerated corrosion tests are performed on reinforced concrete specimens, and a comparison of the statistical index and the equivalent parameters is done for the two types of sensor configurations. The experimental results indicate that the embedded sensor is very sensitive in capturing the changes occurring in the concrete during chloride ingress. However, when the passive film is damaged, thereby initiating corrosion, their sensing ability is reduced. At this point, the lead zirconate titanate patch surface bonded on the rebar is more effective. Overall comparison of experimental results shows that both sensor types can complement each other for an effective detection and monitoring of rebar corrosion.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Concrete Corrosion and Durability · Structural Health Monitoring Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, India

References (31)

Show source-provided references
1. 10.1088/0964-1726/15/2/03710.1088/0964-1726/15/2/037 ↗
2. Annamdas VGM · International Journal of Civil and Structural Engineering · 2010 · 1 · 414
3. Bhalla S · 2007
4. 10.1177/1045389X1245783710.1177/1045389X12457837 ↗
5. 10.1061/(ASCE)0893-1321(2004)17:4(154)10.1061/(ASCE)0893-1321(2004)17:4(154) ↗
6. 10.1177/147592171245870810.1177/1475921712458708 ↗
7. Broomfield JP (2007) Corrosion of Steel in Concrete, Understanding, Investigation and Repair. Second edition. London, UK: Taylor and Francis.
8. 10.1106/N0J5-6UJ2-WlGV-Q8MC10.1106/N0J5-6UJ2-WlGV-Q8MC ↗
9. Hari PK · Smart Materials and Structures · 2012 · 21 · 150
10. IS 1786:1985 · 1985
11. IS 456:2000 · 2000
12. 10.1142/S021797921006499X10.1142/S021797921006499X ↗
13. Kim DJ · 2011
14. 10.1177/1045389X940050010210.1177/1045389X9400500102 ↗
15. 10.2514/6.2011-185910.2514/6.2011-1859 ↗
16. 10.1088/0964-1726/17/5/05500510.1088/0964-1726/17/5/055005 ↗
17. 10.1061/(ASCE)MT.1943-5533.000013310.1061/(ASCE)MT.1943-5533.0000133 ↗
18. 10.1177/147592171143043810.1177/1475921711430438 ↗
19. Scientech Technology (2013) Available at: http://www.scientech.bz
20. 10.1088/0964-1726/17/5/05500210.1088/0964-1726/17/5/055002 ↗
21. Simmers GE (2005) Impedance-based structural health monitoring to detect corrosion. MS Thesis, Department of Mechanical Engineering, Blacksburg, VA.
22. 10.1088/0964-1726/14/4/02610.1088/0964-1726/14/4/026 ↗
23. 10.1088/0964-1726/16/4/00310.1088/0964-1726/16/4/003 ↗
24. 10.1177/1045389X1349831710.1177/1045389X13498317 ↗
25. 10.1177/1045389X1140630310.1177/1045389X11406303 ↗
26. 10.1016/j.cemconres.2010.08.01110.1016/j.cemconres.2010.08.011 ↗
27. 10.1117/12.54115210.1117/12.541152 ↗
28. 10.1177/147592170605797810.1177/1475921706057978 ↗
29. 10.1177/147592170605797910.1177/1475921706057979 ↗
30. 10.3390/s10050519310.3390/s100505193 ↗
31. 10.1088/0964-1726/16/4/03210.1088/0964-1726/16/4/032 ↗