Tribological examination of lumbar intervertebral disc implants
Source abstract
Abstract
The article presents results of friction and wear tests of three-piece systems of the intervertebral disc implant. The number of work cycles proved to have an effect on the coefficient of friction for polyethylene-on-metal and metal-on-metal tribojoints. In addition, for polyethylene-on-metal tribojoints, the effect of compressive force on the coefficient of friction was specified. The influence of working cycles on roughness changes of implant’s working surfaces was analyzed. Based on the microscopic examination of the working surface of implants and morphology of the wear products, the wear mechanism was described. Studies were performed at the Laboratory of Surface Engineering and Tribology in the Metal Forming Institute in Poznan using a SBT-03 simulator.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Spine and Intervertebral Disc Pathology · Tribology and Wear Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Pinchuk, L.S., Chernyakova, Y.M., and Goldade, V.A., The tribology of joints and problems of modern orthopedics, J. Friction Wear, 2008, vol. 29, pp. 224–233.10.3103/S1068366608030124 ↗
2. Źytowski, A., Sosnowski, S., and Wrodycka, B., Spondylarthrosis etiopathogenesis, Pol. Merk. Lek., 2006, vol. 21, pp. 498–501.
3. Jandial, R. and Aryan, H.E., 100 Questions and Answers about Spine Disorders, Ontario: Jones and Bartlett, 2009.
4. Berg, S., Tropp, H.T., and Leivseth, G., Disc height and motion patterns in the lumbar spine in patients operated with total disc replacement or fusion for discogenic back pain. Results from a randomized controlled trial, The Spine J., 2011, vol. 11, pp. 991–998.10.1016/j.spinee.2011.08.434 ↗
5. Gamradt, S.C. and Wang, J.C., Lumbar disc arthroplasty, The Spine J., 2005, vol. 5, pp. 95–103.10.1016/j.spinee.2004.09.006 ↗
6. Urban, J.P. and Roberts, S., Degeneration of the intervertebral disc, Arthritis Research and Therapy, 2003, vol. 5, pp. 120–130.10.1186/ar629 ↗
7. Rasekhi, A., Babaahmadi, A., Assadsangabi, R., et al., Clinical manifestations and MRI findings of patients with hydrated and dehydrated lumbar disc herniation, Academic Radiology, 2006, vol. 13, pp. 1485–1489.10.1016/j.acra.2006.09.047 ↗
8. Adams, A.M. and Dolan, P., Spine biomechanics, J. Biomechanics, 2005, vol. 38, pp. 1972–1983.10.1016/j.jbiomech.2005.03.028 ↗
9. Moojen, W.A., Arts, M.P., Bartels, R.H., et al., Effectiveness of interspinous implant surgery in patients with intermittent neurogenic claudication: a systematic review and meta-analysis, Eur. Spine J., 2011, vol. 20, pp. 1596–1606.10.1007/s00586-011-1873-8 ↗
10. Skalski, K., Skoworodko, J., and Gierzyńska-Dolna, M., Intervertebral disk stabilizers and implants, Obróbka Plastyczna Metali, 2011, vol. 22, pp. 303–317.
11. Grupp, T.M., Yue, J.J., Garcia, R., et al., Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation, Eur. Spine J., 2009, vol. 18, pp. 98–108.10.1007/s00586-008-0840-5 ↗
12. Nowakowski, A., Cabaj, M., and Kubaszewski, M., Lumbar disc arthroplasty — preliminary experience, Neuroskop, 2003, vol. 1, pp. 58–61.
13. Delamarter, R.B., Bae, H.W., and Pradhan, B.B., Clinical results after lumbar total disc replacement: An interim report from the United States clinical trial for the prodisc-II prosthesis, The Orthopedic Clinics of North America, 2005, vol. 36, pp. 301–313.10.1016/j.ocl.2005.03.004 ↗
14. van Ooij, A., Oner, F.C., and Verbout, A.J., Complications of artificial disc replacement: A report of 27 patients with the SB charite disc, J. Spinal Disord Tech., 2003, vol. 16, pp. 369–383.10.1097/00024720-200308000-00009 ↗
15. Austen, S., Punt, I.M., Cleutjens, J.P., et al., Clinical, radiological, histological and retrieval findings of activ-L and mobidisc total disc replacements: a study of two patients, Eur. Spine J., 2012, vol. 21, pp. S513–S520.10.1007/s00586-011-2141-7 ↗
16. McAfee, P.C., Salari, B., and Saiedy, S., Reoperations and complications of failed lumbar total disk replacement, Seminars in Spine Surgery, 2012, vol. 34, pp. 37–42.10.1053/j.semss.2011.11.008 ↗
17. Panin, S.V., Kornienko, L.A., Sondghaitam, N., et al., Abrasive wear of micro- and nanocomposites based on ultra-high-molecular-weight polyethylene (UHMWPE): Part 2. Composites based on UHMWPE filled by nanoparticles and nanofibers, J. Friction Wear, 2012, vol. 33, pp. 453–459.10.3103/S1068366612060074 ↗
18. Gierzyńska-Dolna, M., Biotribologia, Cz stochowa: Wydawn. Politech. Czestochow., 2002
19. Whatley, B.R. and Wen, X., Intervertebral disc (IVD): structure, degeneration, repair and regeneration, Mater. Sci. Eng.: C, 2012, vol. 32, pp. 61–77.10.1016/j.msec.2011.10.011 ↗
20. Markuszewski, J., Łapaj, Ł., Kokoszka, P., et al., Physical activity and quality of life following total uncemented hip replacement and hip resurfacing, Chirur. Narzad. Ruchu Ortop. Polska, 2009, vol. 74, pp. 48–52.
21. Lapaj, L., Markuszewski, J., Wierusz-Kozłowska, M., et al., 30-year survival of a McKee-Farrar hip prosthesiscase report and microscopic analysis of bearing surface, Polish Orthoped. Traumat., 2012, vol. 77, pp. 17–20.
22. Bisseling, P., Zeilstra, D.J., Hol, A.M., et al., Metal ion levels in patients with a lumbar metal-on-metal total disc replacement: should we be concerned? J. Bone Joint Surg. Br., 2011, vol. 93, pp. 949–954.10.1302/0301-620X.93B7.26392 ↗
23. Moghadas, P., Mahomed, A., Hukins, D.W., et al., Friction in metal-on-metal total disc arthroplasty: effect of ball radius, J. Biomechanics, 2012, vol. 45, pp. 504–509.10.1016/j.jbiomech.2011.11.045 ↗
24. Mróz, A., Wiśniewski, T., Gierzyńska-Dolna, M., et al., A device for testing of tribological properties of intervertebral disc endoprosthesis — SBT-03.1 simulator, Proc. Conf. on Biomaterials in Medicine and Veterinary Medicine, 2012.
25. Okazaki, Y., Gotoh, E., Nishimori, M., et al., Osteocompatibility of stainless steel, Co-Cr-Mo, Ti-6Al-4V and Ti-15Zr-4Nb-4Ta alloy implants in rat bone tissue, Mater. Trans., 2005, vol. 46, 1610–1617.10.2320/matertrans.46.1610 ↗