journal article·2011-01

Estimation of Peak Heat Release Rate of a Forest Fuel Bed in Outdoor Laboratory Conditions

J. Madrigal, M. Guijarro, C. Hernando, C. Díez, E. Marino

Journal of Fire Sciences· Volume 29· Issue 1
Publisher page

Abstract

Experimental tests were carried out with an adapted bench-scale mass loss calorimeter (MLC) and also in an outdoor wind tunnel to estimate the heat release rate (HRR) of a forest fuel bed. The MLC apparatus uses a calibrated thermopile to quantify the HRR, as an alternative to the classical measurement of oxygen consumption due to combustion. Additional calibration of thermocouples to measure gas temperatures enabled estimation of HRR in experimental burnings conducted in the wind tunnel. The results showed a reasonable agreement between peak HRR (PHRR) values obtained in the MLC and in the wind tunnel, and also demonstrated that PHRR was significantly affected by the wind speed and the rate of spread. The proposed procedure is potentially useful as an initial step in monitoring HRR in outdoor forest fire experiments.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Thermochemical Biomass Conversion Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Centro de Investigación Forestal. Instituto Nacional de Investigación y Tecnología Agraria y Alimentaria (CIFOR-INIA), Crta. La Coruña Km 7.5, 28040 Madrid, Spain,

Centro de Investigación Forestal. Instituto Nacional de Investigación y Tecnología Agraria y Alimentaria (CIFOR-INIA), Crta. La Coruña Km 7.5, 28040 Madrid, Spain

References (23)

Show source-provided references
1. 10.1016/S0360-1285(03)00017-010.1016/S0360-1285(03)00017-0 ↗
2. 10.1071/WF0614310.1071/WF06143 ↗
3. 10.1016/j.expthermflusci.2007.11.01110.1016/j.expthermflusci.2007.11.011 ↗
4. 10.1016/0379-7112(92)90019-910.1016/0379-7112(92)90019-9 ↗
5. Janssens, M.L. ( 2001). Heat Release Rate (HRR), In: Ohlemiller, T.J., Johnson, E.L. and Gann, R.G. (eds), Proceedings of an International Workshop (NISTIR 6527), Measurement Needs for Fire Safety, National Institute of Standard and Technology, Gaithersburg , 4-7 April, pp. 186-200.
6. 10.1002/fam.81008020610.1002/fam.810080206 ↗
7. Babrauskas, V. ( 2002). The Cone Calorimeter, In: Society of Fire Protection Engineering (ed.), SFPE Handbook of Fire Protection Engineering , 3rd edn, pp. 3-63-3-81, National Fire Protection Association, Quincy, Mass.
8. International Organization for Standardization · 2001
9. 10.1520/JTE11035J10.1520/JTE11035J ↗
10. Gill, A.M. and Knight, I.K. ( 1991). Fire Measurement, In: Cheney, N.P. and Gill, A.M. (eds), Bushfire Modelling and Fire Danger Rating System, pp. 137-146, CSIRO Division of forestry, Canberra.
11. 10.2172/50531310.2172/505313 ↗
12. 10.1139/x05-25310.1139/x05-253 ↗
13. 10.1177/073490410910203010.1177/0734904109102030 ↗
14. 10.1007/BF0103774310.1007/BF01037743 ↗
15. 10.1016/j.firesaf.2005.05.00910.1016/j.firesaf.2005.05.009 ↗
16. Hernando, C.
17. 10.2495/FIVA08014110.2495/FIVA080141 ↗
18. European Commission · 1997
19. Weber, R.O. · CALM Science Supplement · 1995 · 4 · 17
20. White, R.H.
21. Wold, H. · Encyclopedia of Statisitical Sciences · 1985 · 6 · 581
22. 10.1071/WF0510310.1071/WF05103 ↗
23. 10.1071/WF0403510.1071/WF04035 ↗