Ignition Properties of Fabrics
Source abstract
Abstract
ASTM E2058 (NFPA 287) Fire Propagation apparatus was used to determine the Critical Heat Flux (CHF) and Thermal Response Parameter (TRP thin ) of 10 fabrics by measuring time to ignition at different heat flux values. CHF values were in the range 15–25 kW/m 2 and decreased with fabric areal density and cation content. TRP thin values expressed as areal density heat capacity ignition temperature above ambient were in the range 500–2439kW-s/m 2 . There was a reasonable correlation between the measured TRP thin values and the areal density of the fabrics examined in this study. Light areal density fabrics with low TRP thin values (≤ 1000 kW-s/m 2 ) had high ignitions with the fast smoldering cigarette, while heavy areal density fabrics (≥ 1200 kW-s/m 2 ) had high ignitions with the slow smoldering cigarette.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Textile materials and evaluations · Flame retardant materials and properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Brown & Williamson Tobacco Corporation P.O. Box 1056, Macon, GA 31202 – 1056
Factory Mutual Research Corporation P.O. Box 9102, Norwood, MA 02062
References (12)
Show source-provided references
1. 10.1177/07349041950130060310.1177/073490419501300603 ↗
2. 10.1177/07349041950130010410.1177/073490419501300104 ↗
3. Wanna, J.T. · 49
4. Tewarson, A. · 1999
5. 10.6028/NIST.SP.851-210.6028/NIST.SP.851-2 ↗
6. Murty Kanuary, A. · 1995 · 2
7. Quintiere, J.G. · 1995 · 2
8. Tewarson, A. · 1996
9. 10.1177/07349041940120040210.1177/073490419401200402 ↗
10. 10.1177/07349041860040040210.1177/073490418600400402 ↗
11. Rangaprasad, N. · 1976 · 101
12. 10.1177/07349041970150060310.1177/073490419701500603 ↗