Synergism of GUP and Boric Acid Characterized by Cone Calorimetry and Thermogravimetry
Source abstract
Abstract
Wood is treated with a new composite flame retardant, whose components guanyl urea phosphate (GUP) and boric acid (BA) impart flame retardance. The flame retarding behavior of these samples is measured by cone calorimeter. The thermal behavior of samples has been studied by differential thermogravimetry (DTG) and thermogravimetry (TG) in air. The activation energies for different stages of thermal degradation are obtained following the method of Broido, A. (1969). J. Polym. Sci., Part 2, 7: 1761. It is found that the combustion parameters of wood, including rate of heat release (RHR) and total heat release (THR) are decreased considerably by the treatment, especially for wood treated with the composite flame retardant of wood (FRW) because of a strong synergistic effect of flame retardance between GUP and boric acid. The mechanism of synergism is explained by analyzing the TG data. The GUP can accelerate dehydration and carbonization while BA can relatively increase thermal stabilization of wood. Their synthetical actions result in more char and less flammable volatile products, obtaining good flame retardance.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Flame retardant materials and properties · Fire dynamics and safety research · Thermal and Kinetic Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Resources and Environmental Engineering North China Institute of Science and Technology National Safety Training Center of Coal Mines PO Box 206, Yanjiao, Beijing 101601, PR China
Department of Teaching North China Institute of Science and Technology National Safety Training Center of Coal Mines PO Box 206, Yanjiao, Beijing 101601, PR China
School of Material Science and Engineering Beijing Institute of Technology, Beijing 100081, PR China
References (21)
Show source-provided references
1. Goldstein I.S. (1959). U.S. Pat. No. 2,917,408.
2. Goldstein, I.S. and Dreher, W.A. (1964). U.S. Pat. No. 3,159,503.10.1016/B978-1-4831-9812-5.50012-6 ↗
3. Juneja, S.C., Ottawa and Ontario (1975). U.S. Pat. No. 3,887,511.
4. Surdyk (1975). U.S. Pat. No. 3,874,990.
5. Loyvet, Andre G., Morgan and Dennis J. (1984). U.S. Pat. No. 4,461,720.
6. Babrauskas, V. (1982). Development of Cone Calorimeter—A Bench Scale Rate of Heat Release Based on Oxygen Consumption, NBS-IR 82-2611, US Nat. Bur. Stand., Gaithersburg .10.6028/NBS.IR.82-2611 ↗
7. 10.1002/fam.81008020610.1002/fam.810080206 ↗
8. Giraud, S. · Journal of Fire Sciences · 2001 · 31 · 11
9. Babrauskas, V. · 1992
10. Tang, W.K. · 1967
11. 10.1002/app.1970.07014051810.1002/app.1970.070140518 ↗
12. Beal, F.C. · 1970
13. 10.1002/fam.81015010610.1002/fam.810150106 ↗
14. 10.1002/pol.1969.16007101210.1002/pol.1969.160071012 ↗
15. 10.1016/S1573-4374(99)80017-X10.1016/S1573-4374(99)80017-X ↗
16. 10.1002/app.1985.07030030210.1002/app.1985.070300302 ↗
17. 10.1177/073490410302100300210.1177/0734904103021003002 ↗
18. 10.1080/0010220049051484010.1080/00102200490514840 ↗
19. 10.1016/j.jaap.2005.01.00610.1016/j.jaap.2005.01.006 ↗
20. 10.1080/1532179960801485910.1080/15321799608014859 ↗
21. 10.1002/app.1987.07033051010.1002/app.1987.070330510 ↗