Thermal degradation of self-contained breathing apparatus facepiece lenses under radiant thermal loads
Source abstract
Abstract
The self-contained breathing apparatus is one of the most critical components of the firefighting personal protective ensemble providing protection from potentially toxic gases and products of combustion. Three models of self-contained breathing apparatus facepiece lenses meeting various editions of national standards were exposed to radiant thermal loads of 5, 10, 15, and 20 kW/m 2 until thermal degradation resulted in hole formation or the test duration reached 30 min. Thermal damage was documented as time to crazing, bubbling, and hole formation. Temperature was recorded within the facepiece. There were significant differences in times to thermal damage between lenses. The facepiece lens model meeting the 2013 edition of National Fire Protection Association 1981 had significantly longer times to thermal degradation than those meeting older editions of the standard. Maximum temperatures were higher in the facepiece model meeting the 2013 edition of National Fire Protection Association 1981, likely because of the extended time the radiant load was applied.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Risk and Safety Analysis · Fire dynamics and safety research · Safety Warnings and Signage
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Fire Safety Research Institute, UL Research Institutes, Columbia, MD, USA
Illinois Fire Service Institute, University of Illinois Urbana-Champaign, Champaign, IL, USA
Funding
Federal Emergency Management Agency
References (23)
Show source-provided references
1. Mensch A, Braga G, Bryner N. Fire exposures of fire fighter self-contained breathing apparatus facepiece lenses. NIST technical note 1724, 2011, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=909917
2. National Fire Protection Association (NFPA). Self-contained breathing apparatus. NFPA safety alert, 2012, https://www.seinet.org/sites/default/files/2020-10/NFPA_Alert_Notice-SCBA_Lenses_07.02.2012.pdf
3. Romano N
4. Berardinelli S
5. Berardinelli S
6. Bowyer M
7. Wertman S, Miles S. Volunteer fire fighter dies while lost in residential structure fire—Alabama. Report no. F2008-34, 2009. Fire Fighter Fatality Investigation and Prevention Program (FFFIPP), https://www.cdc.gov/niosh/fire/pdfs/face200834.pdf
8. Merinar T
9. 10.6028/NIST.SP.112310.6028/NIST.SP.1123 ↗
10. Putorti A
11. National Fire Protection Association (NFPA) 1981:2013. Standard on open-circuit self-contained breathing apparatus (SCBA) for emergency services.
12. 10.1016/j.burns.2014.11.00810.1016/j.burns.2014.11.008 ↗
13. Madrzykowski D · 2011
14. 10.1007/s10694-015-0555-110.1007/s10694-015-0555-1 ↗
15. 10.54206/102376/DNYQ216410.54206/102376/DNYQ2164 ↗
16. 10.1007/s10694-019-00864-210.1007/s10694-019-00864-2 ↗
17. Madrzykowski D
18. 10.6028/NIST.GCR.17-01410.6028/NIST.GCR.17-014 ↗
19. 10.6028/NIST.GCR.18-01910.6028/NIST.GCR.18-019 ↗
20. Posi 3 USB: computerized performance tester for air-supplied breathing apparatus . Honeywell Analytics, Inc. 2015, https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/his/ru-ru/products/respiratory-protection/documents/scba-test-bench/04-Posi3%20USB%20Set%20up%20Guide%20Rev%205.pdf
21. Donnelly MK
22. Cossell C, Ma J, Spindel S, et al. Tracheal burning from hot air inhalation. Report, Cornell University, Ithaca, NY, 2007, https://hdl.handle.net/1813/7903