Width effects on downward flame spread over poly(methyl methacrylate) sheets
Source abstract
Abstract
The experiments of downward flame spread over poly(methyl methacrylate) sheets with different dimensions were conducted in this study. In comparison with flame spread over samples under infinite width condition, lateral air entrainment shows significant influence on downward flame spread of finite width. The characteristic angles, defined as those produced on sample residues in a steady-state stage, are constant for different dimensions. Based on the characteristic angles and with reasonable assumptions, a three-dimensional theoretical model is proposed to illustrate the experimental results. Width effects on downward flame spread over thicker samples are more obvious and they fade away with gradual increase in width. Moreover, the heat flux penetrating through the solid surface at the front of the pyrolysis region is higher than that in the two-dimensional case. The flame height correlates well with mass loss rate as an exponential function with a mean power value of 0.79.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Fire dynamics and safety research · Flame retardant materials and properties · Combustion and Detonation Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, China
China-hemp Research Center, Beijing, China
References (27)
Show source-provided references
1. 10.1080/0010220830892365010.1080/00102208308923650 ↗
2. 10.1016/0360-1285(93)90022-710.1016/0360-1285(93)90022-7 ↗
3. 10.1016/S0082-0784(69)80407-810.1016/S0082-0784(69)80407-8 ↗
4. 10.1080/0010220760894674510.1080/00102207608946745 ↗
5. 10.1016/S0082-0784(06)80787-310.1016/S0082-0784(06)80787-3 ↗
6. 10.1016/S0010-2180(99)00049-810.1016/S0010-2180(99)00049-8 ↗
7. 10.1016/S0082-0784(00)80713-410.1016/S0082-0784(00)80713-4 ↗
8. 10.1177/073490410706235610.1177/0734904107062356 ↗
9. 10.1016/S0010-2180(74)80029-510.1016/S0010-2180(74)80029-5 ↗
10. 10.1016/j.firesaf.2005.12.00310.1016/j.firesaf.2005.12.003 ↗
11. 10.1080/00102202.2011.58408910.1080/00102202.2011.584089 ↗
12. 10.1016/S0082-0784(00)80700-610.1016/S0082-0784(00)80700-6 ↗
13. 10.1080/00102202.2011.64803310.1080/00102202.2011.648033 ↗
14. 10.1016/j.firesaf.2012.02.00610.1016/j.firesaf.2012.02.006 ↗
15. 10.1177/073490411350567710.1177/0734904113505677 ↗
16. 10.1080/0010220760894675310.1080/00102207608946753 ↗
17. 10.1080/0010220100369484210.1080/00102201003694842 ↗
18. 10.1016/0010-2180(88)90007-710.1016/0010-2180(88)90007-7 ↗
19. 10.1080/0010220029002143410.1080/00102200290021434 ↗
20. Markstein GH · J Fire Flammability · 1975 · 6 · 140
21. 10.1016/j.combustflame.2010.12.00510.1016/j.combustflame.2010.12.005 ↗
22. 10.1080/0010220840892378910.1080/00102208408923789 ↗
23. 10.1080/0010220860892389310.1080/00102208608923893 ↗
24. 10.1002/fam.80910.1002/fam.809 ↗
25. 10.1016/j.proci.2006.07.23510.1016/j.proci.2006.07.235 ↗
26. 10.1016/j.firesaf.2008.09.00310.1016/j.firesaf.2008.09.003 ↗
27. 10.1016/j.firesaf.2009.06.00310.1016/j.firesaf.2009.06.003 ↗