journal article·2026-03

Performance evaluation of outlet types in indoor fire hydrant systems

Misuk Kim, Hasung Kong

Journal of Fire Sciences· Volume 44· Issue 2
Publisher page

Abstract

Rapid suppression of incipient fires is essential for reducing casualties and property damage, and the effectiveness of response often depends on the activation speed of indoor fire hydrant systems. This study examines delays caused by manual activation and evaluates the efficiency of automated solutions. Controlled experiments were conducted with 10 participants operating hydrant cabinets equipped with electronically actuated solenoid valves, motorised valves and old- and new-type angle valves. Each participant performed five activation trials per valve type from a distance of 3 m. Operating time, defined as the interval from cabinet opening to water discharge, was averaged for comparison. Results showed clear differences: electronically actuated valves ranged from 6.74 to 13.4 s, old-type angle valves from 10.2 to 17.8 s, and motorised valves were fastest at 3.81 to 6.55 s. Automated valve systems consistently outperformed manual valves, demonstrating that electronically controlled and motorised solutions significantly improve response speed and reliability in indoor fire hydrant systems.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Injury Epidemiology and Prevention · Evacuation and Crowd Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Fire and Safety Engineering, Woosuk University, Wanju County, South Korea

Department of Fire and Disaster Prevention, Woosuk University, Wanju County, South Korea

References (25)

Show source-provided references
1. 10.5334/bc.20110.5334/bc.201 ↗
2. 10.1016/j.asej.2024.10301010.1016/j.asej.2024.103010 ↗
3. Hong SH, Kong HS. Comparison of waterproofing preparation time with the unfolded of donut-type staking method fire hose in indoor hydrant system. J Korea Saf Manag Sci 2021; 23(3): 115–122.
4. 10.1016/j.heliyon.2024.e2726410.1016/j.heliyon.2024.e27264 ↗
5. 10.9798/KOSHAM.2025.25.4.6310.9798/KOSHAM.2025.25.4.63 ↗
6. 10.1007/s10694-023-01539-910.1007/s10694-023-01539-9 ↗
7. 10.3390/w1611148810.3390/w16111488 ↗
8. Stas S, Bychenko A, Pustovit M, et al. Experimental research of geometric parameters change of fire hoses when using the Protek 366 nozzle. Bull Natl Tech Univ Khpi Hydraul Mach Hydraul Units 2022(1): 78–82.
9. Crane Co. Technical paper No. 410: Flow of fluids through valves fittings and pipe. Crane Co 1982 https://www.researchgate.net/profile/Brian-Hanley-6/post/How-to-calculate-the-Nitrogen-flowrate-knowing-pressure-in-pipe-line-and-pipe-diameter/attachment/59d63db579197b807799a767/AS%3A421054863429633%401477398710366/download/Flow+of+Fluids+-+Through+Valve%2C+Fittings+and+Pipes.pdf
10. 10.54691/bcpbm.v17i.35310.54691/bcpbm.v17i.353 ↗
11. 10.20473/ajim.v5i2.5755110.20473/ajim.v5i2.57551 ↗
12. 10.23919/CCC63176.2024.1066235210.23919/CCC63176.2024.10662352 ↗
13. 10.3390/fire401000810.3390/fire4010008 ↗
14. 10.1016/j.procs.2024.10.03510.1016/j.procs.2024.10.035 ↗
15. 10.3390/buildings1312301810.3390/buildings13123018 ↗
16. 10.1016/j.firesaf.2023.10398410.1016/j.firesaf.2023.103984 ↗
17. 10.3390/muscles301000910.3390/muscles3010009 ↗
18. 10.1088/1742-6596/2860/1/01202910.1088/1742-6596/2860/1/012029 ↗
19. 10.1016/j.jobe.2021.10319710.1016/j.jobe.2021.103197 ↗
20. 10.7731/KIFSE.2013.27.4.1310.7731/KIFSE.2013.27.4.13 ↗
21. 10.1088/1755-1315/152/1/01203010.1088/1755-1315/152/1/012030 ↗
22. Vigram KM, Ramji M. Autonomous firefighting robot for enhanced fire detection and suppression. In: Proceedings of the 3rd international conference on intelligent data communication technologies and internet of things, Bengaluru, India, 13 March 2025, pp. 1070–1076. New York: IEEE.
23. 10.7731/KIFSE.2012.26.3.06710.7731/KIFSE.2012.26.3.067 ↗
24. 10.7731/KIFSE.2019.33.2.06310.7731/KIFSE.2019.33.2.063 ↗
25. 10.1007/s10694-016-0617-z10.1007/s10694-016-0617-z ↗