Development and validation of simple-shield thermocouple in fire environments
Source abstract
Abstract
A novel simple-shield thermocouple that is capable of radiation correction in fire environments and that has a simpler structure and greater convenience than conventional aspirated thermocouples was proposed. The measurement errors of bare-bead, double-shield aspirated, and simple-shield thermocouples were then compared in a simulated fire environment. In addition, a fire experiment using wood cribs was performed in order to verify the measurement performance of the proposed simple-shield thermocouple in a real fire environment using a one-third-scale ISO 9705 room. The simple-shield thermocouple produced fairly accurate temperatures that fell within 5% of the actual gas temperature in the simulated fire environment. In addition, variations in the surface emissivity and the installation angle of the simple-shield thermocouple in the real fire environment further reduced the measurement error. With a radiant heat flux of 20 kW/m 2 , it was confirmed that the bare-bead thermocouple had a relative measurement error of up to 80% compared to the aspirated thermocouple, while the proposed simple-shield thermocouple was capable of measuring the temperature within a relative error of around 15% compared to the aspirated thermocouple.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Wind and Air Flow Studies · Fire dynamics and safety research · Calibration and Measurement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Fire and Disaster Prevention, Daejeon University, Daejeon, South Korea
Funding
the National Fire Agency
References (29)
Show source-provided references
1. 10.1063/1.312832310.1063/1.3128323 ↗
2. 10.1016/j.ijthermalsci.2017.08.01410.1016/j.ijthermalsci.2017.08.014 ↗
3. 10.1080/0010220970894681310.1080/00102209708946813 ↗
4. Moffatt EM · Instruments · 1949 · 22 · 122
5. 10.6028/NIST.SP.250-3510.6028/NIST.SP.250-35 ↗
6. Pitts WM
7. 10.1177/073490410809351610.1177/0734904108093516 ↗
8. Kim SC · J Korean Inst Fire Sci Eng · 2010 · 24 · 98
9. 10.1177/07349041950130040110.1177/073490419501300401 ↗
10. Blevins LG · 1
11. 10.1016/S0379-7112(99)00034-X10.1016/S0379-7112(99)00034-X ↗
12. 10.1016/j.firesaf.2004.03.00210.1016/j.firesaf.2004.03.002 ↗
13. 10.1177/07349041970150060210.1177/073490419701500602 ↗
14. Newman Jeffrey S · J Fire Flammability · 1979 · 10 · 326
15. Mammoser III JH · 695
16. 10.1016/0360-1285(93)90017-910.1016/0360-1285(93)90017-9 ↗
17. Nakos J · 283
18. Glawe GE
19. Han HS · J Korean Soci Safety · 2017 · 32 · 7
20. Han HS · J Korean Society of Safety · 2017 · 32 · 14
21. 10.1243/JMES_JOUR_1968_010_048_0210.1243/JMES_JOUR_1968_010_048_02 ↗
22. 10.1002/aic.69018021910.1002/aic.690180219 ↗
23. 10.1115/1.344964710.1115/1.3449647 ↗
24. Steckler KD10.6028/NBS.IR.82-2520 ↗
25. 10.7731/KIFSE.2013.27.3.02010.7731/KIFSE.2013.27.3.020 ↗
26. 10.1177/073490411036310610.1177/0734904110363106 ↗
27. 10.14257/astl.2015.89.1510.14257/astl.2015.89.15 ↗
28. McGrattan K
29. 10.6028/NIST.IR.646710.6028/NIST.IR.6467 ↗