Metal Chelates as Flame Retardants and Smoke Suppressants for Flexible Poly (Vinyl Chloride)
Source abstract
Abstract
The thermal degradation in air of flexible PVC treated with various metal chelates containing Fe, Co, Ni, Cu, or Zn combined with two compounds Al(OH) 3 and Mg(OH) 2 , have been studied by differential thermal analysis and thermogravimetry from ambient temperature to 1023 K. The kinetic parameters were obtained using the equation of Kissinger. Flexible PVC treated with flame-retardants showed a high limiting oxygen index, char yield and a low smoke density rating, maximum smoke density, which indicated that the flame retardance of the treated PVC was improved.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Flame retardant materials and properties · Polymer Science and PVC · Polymer Nanocomposites and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Chemistry and Environmental Science Hebei University, Baoding 071002, P.R. China
References (23)
Show source-provided references
1. 1. Hirschler, M.M. (1998). Fire Performance of Poly (Vinyl Chloride) Updated and Recent Developments , Flame Retardants, 98: 103-103 .
2. 2. Hirschler, M.M. (1982). Recent Developments in Flame-Retardant Mechanisms, Development in Polymer Stabilisation, Vol. 5, p. 107-107, Applied Science Publ, London .
3. 10.1002/1097-4628(20000929)77:14<3119::AID-APP130>3.0.CO;2-N10.1002/1097-4628(20000929)77:14<3119::AID-APP130>3.0.CO;2-N ↗
4. 10.1016/0141-3910(90)90118-Q10.1016/0141-3910(90)90118-Q ↗
5. 5. Jha, N.K., Misra, A.C. and Bajaj, P. (1984). Flame-Retardant Additives for Polypropylene , J. Macromol Sci., Rev. Macromol. Chem. Phys., C24: 1: 69-69 .10.1080/07366578408069971 ↗
6. 10.1351/pac19865806092510.1351/pac198658060925 ↗
7. 10.1002/app.1980.07025030810.1002/app.1980.070250308 ↗
8. 10.1002/pol.1977.17015022310.1002/pol.1977.170150223 ↗
9. 10.1007/BF0055324110.1007/BF00553241 ↗
10. 10.1002/app.1992.07046031410.1002/app.1992.070460314 ↗
11. 11. Gonzalez, L.A. and Mendiola, A.J. (1981). Effect of Various Metal Oxides on the Combustion of Soft PVC , Rev. Plast. Mod., 42(31): 58-58 .
12. 10.1002/(SICI)1099-0739(199603)10:2<101::AID-AOC484>3.0.CO;2-710.1002/(SICI)1099-0739(199603)10:2<101::AID-AOC484>3.0.CO;2-7 ↗
13. 10.1016/0165-2370(85)80023-110.1016/0165-2370(85)80023-1 ↗
14. 14. Cullis, C.F., Gad, A.M.M. and Hirschler, M.M. (1984). Metal Chelates as Flame Retardants and Smoke Suppressants for Thermoplastic Polymers , Eur. Polym. J., 20: 710-710 .10.1016/0014-3057(84)90152-6 ↗
15. 10.1016/0014-3057(84)90222-210.1016/0014-3057(84)90222-2 ↗
16. 16. Cao, H.M. (1988). Inorganic Chemistry Compound Handbook (Wuji Huahewu hecheng Shouce), 3: 608-608 , Industry of Chemistry Publishing Company, Beijing .
17. 10.1177/073490410202000390510.1177/0734904102020003905 ↗
18. 18. Hirschler, M.M. (1986). Thermal Decomposition (STA and DSC) of PVC Compounds Under a Variety of Atmospheres and Heating Rates , Eur. Polym. J., 20: 710-710 .
19. 19. Brauman, S.K., Fishman, N. and Brolly, A.S. (1976). Smoke Generation from the Burning of some Polymeric Materials , J. Fire Retardant Chem., 3: 66-66 .
20. 10.6028/jres.057.02610.6028/jres.057.026 ↗
21. 10.1016/0032-3861(83)90200-810.1016/0032-3861(83)90200-8 ↗
22. 22. Brauman, S.K. (1976). Fire Retardance of Polymers Containing Antimony Oxide-halogen , J. Fire Retardant Chem., 3: 117-117 .
23. 10.1080/0010220940895187710.1080/00102209408951877 ↗