journal article·2025-11Open access

Fire performance of high-density polyethylene sheets protected by a coating of plasticized polyvinyl chloride/modified-vermiculite

Walter Wilhelm Focke, Washington Mhike, Joseph Kwaku Ofori Asante, Isbé van der Westhuizen, Eduard Jacobus Snyman, Maria Atanasova

Journal of Fire Sciences· Volume 43· Issue 5-6

Abstract

Treatment of Palabora vermiculite with ammonium chloride or ammonium nitrate solutions caused the collapse of its structure, resulting in a reduction of the exfoliation onset temperature by more than 200°C. It is speculated that ammonium ions enter the hydrobiotite galleries as guest ions partially replacing the hydration water associated with the magnesium ions. The effectiveness of various modified vermiculite flakes as flame-retardant fillers was evaluated in laminates of high-density polyethylene and plasticized polyvinyl chloride/vermiculite-modified composites. The laminates comprised a high-density polyethylene sheet coated with polyvinyl chloride plasticized with 100 phr of a phosphate ester and filled with 40 phr vermiculite. Cone calorimetry results, measured at a radiant flux of 35 kW m −2 , revealed that copper-ion modified vermiculite was the most effective flame-retardant additive. Laminates coated with polyvinyl chloride containing copper-ion-modified vermiculite exhibited a significantly reduced peak heat release rate of 64kW/m 2 , compared to 677kW/m 2 for uncoated high-density polyethylene, demonstrating the potential of polyvinyl chloride–based flame-retardant coatings incorporating copper-ion-modified vermiculite for polyethylene.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Flame retardant materials and properties · Polymer Nanocomposites and Properties · Synthesis and properties of polymers

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemical Engineering, University of Pretoria, Hatfield, Pretoria, South Africa

Polymer Technology Division, Department of Chemical, Metallurgical and Materials Engineering, Tshwane University of Technology, Pretoria, South Africa

Department of Physics, Tshwane University of Technology, Pretoria, South Africa

References (38)

Show source-provided references
1. Schwellnus CM. Vermiculite deposits in the Palaboroa area, NE Transvaal. Pretoria, South Africa: Government Printer, 1938.
2. Bassett WA. The geology of vermiculite occurrences. Clays Clay Miner 1961; 10: 61–69.
3. Schoeman J. Mica and vermiculite in South Africa. J South Afr Inst Min Metall 1989; 89: 1–12.
4. 10.1016/j.clay.2010.06.02310.1016/j.clay.2010.06.023 ↗
5. 10.1007/978-3-642-65917-1_810.1007/978-3-642-65917-1_8 ↗
6. Newman A Brown G. The chemical constitution of clays. London: Mineralogical Society 1987 pp. 1–128.
7. 10.1007/BF0254655510.1007/BF02546555 ↗
8. 10.1180/claymin.2013.048.4.0110.1180/claymin.2013.048.4.01 ↗
9. Marwa EMM. Confusion in the literature of vermiculite. In: Wesley LR (ed) Clays and clay minerals: geological origin, mechanical properties and industrial applications. New York: Nova Science Publishers, 2014, pp. 435–446.
10. 10.1126/science.156.3773.38510.1126/science.156.3773.385 ↗
11. 10.1080/15421406.2012.63436710.1080/15421406.2012.634367 ↗
12. 10.1016/j.clay.2014.12.01910.1016/j.clay.2014.12.019 ↗
13. 10.1002/app.3311310.1002/app.33113 ↗
14. 10.1080/00222348.2012.76039210.1080/00222348.2012.760392 ↗
15. 10.1002/pen.2477510.1002/pen.24775 ↗
16. 10.1063/1.508483010.1063/1.5084830 ↗
17. 10.1515/epoly-2019-006010.1515/epoly-2019-0060 ↗
18. 10.3390/polym1418377710.3390/polym14183777 ↗
19. Wan Amalina Wan Z, Ariwahjoedi B, Hussain P. Effect of vermiculite on fire protectiveness of water-based acrylic fire retardant coating. In: 2010 IEEE Student Conference on Research and Development (Scored), Kuala Lumpur, Malaysia, 13–14 December 2010, pp. 410–414. New York: IEEE.
20. 10.1007/s11998-014-9626-310.1007/s11998-014-9626-3 ↗
21. 10.1039/C5RA08382F10.1039/C5RA08382F ↗
22. 10.1039/D1NA00207D10.1039/D1NA00207D ↗
23. 10.1039/C9RA02134E10.1039/C9RA02134E ↗
24. ISO. 5660-1: 2002 Reaction to fire tests. Heat release smoke production and mass loss rate https://www.iso.org/standard/35351.html.
25. ISO. 5660-2: 2002. Reaction to fire tests. Heat release smoke production and mass loss rate https://www.iso.org/standard/32431.html.
26. ISO/TR. 5660-3: 2003. Reaction to fire tests. Heat release smoke production and mass loss rate https://www.iso.org/standard/38322.html.
27. Nasirzadeh M Yahyaei H Mohseni M. Effects of inorganic fillers on the performance of the water-based intumescent fire-retardant coating 2023; 47: 51–61.10.1002/fam.3067 ↗
28. 10.3390/polym1412250110.3390/polym14122501 ↗
29. 10.1016/0379-7112(92)90019-910.1016/0379-7112(92)90019-9 ↗
30. 10.1002/fam.94910.1002/fam.949 ↗
31. 10.1533/9781845694701.2.25510.1533/9781845694701.2.255 ↗
32. 10.3390/ijms22191082510.3390/ijms221910825 ↗
33. 10.1177/07349041940120010210.1177/073490419401200102 ↗
34. 10.1016/j.polymdegradstab.2010.03.01510.1016/j.polymdegradstab.2010.03.015 ↗
35. 10.3801/IAFSS.FSS.10-21310.3801/IAFSS.FSS.10-213 ↗
36. 10.1016/0379-0738(84)90090-210.1016/0379-0738(84)90090-2 ↗
37. Hirschler MM. Fire Retardance, Smoke Toxicity and Fire Hazard. In: Flame retardants ‘94 British Plastics Federation. London: Interscience Communications, 1994, pp. 225–237.
38. OSHA Z-. OSHA Annotated Table Z-1. Permissible exposure Limits – annotated tables https://www.osha.gov/annotated-pels/table-z-1 (2022 accessed 19 August 2022).