journal article·2017-01-01Open access

Immobilization of Glucose Oxidase on a PVA/PAA Nanofiber Matrix Reduces the Effect of the Hematocrit Levels on a Glucose Biosensor

KYU-OH KIM, BYOUNG-SUHK KIM

Abstract

A sensitive and selective amperometric glucose biosensor based on a PVA/PAA nanofiber layer deposited on a copper/Ni electrode was investigated. Typically, many currently available point-of-care glucose sensors demonstrate a decreasing response to the analyte in the presence of increasing hematocrit levels (blood-to-plasma difference). A sensor electrode for glucose is described that displays a reduced sensitivity to changes in hematocrit levels. The base layer of the sensor consists of PVA/PAA-GOD-coated nanofibers impregnated with a mixture of glucose oxidase and a ruthenium redox mediator. It has an average diameter of approximately 510 ± 50 nm (100–150 ± 20 nm for the glucose oxidase aggregates), an average pore diameter of 2.7 ± 0.5 μm and a thickness of less than 20 μm. The copper/Ni electrode has a low electrical resistance, less than 0.01 Ω, and it may be possible to mass produce the biosensor electrode with a uniform electrical resistance. The current of the PVA/PAA-GOD-coated nanofiber glucose biosensor shows no hematocrit effect on glucose measurements at hematocrit levels from 35% to 60% for glucose concentrations from 37.1 mg/dL (2.06 mmol/L) to 544.7 mg/dL (30.24 mmol/L). The glucose sensor with a PVA/PAA-GOD-coated nanofiber deposited on a Copper/Ni electrode on PET film exhibits a relatively short response time (approximately 3 s) and a sensitivity of 0.85 μAmM­1 with a linear range from 0 to 33 mM glucose. The sensor has excellent reproducibility with a correlation coefficient of 0.9989 and a total nonlinearity error of 2.65%.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Electrospun Nanofibers in Biomedical Applications · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Fiber System Engineering, Dankook University

Department of Organic Materials & Fiber Engineering, Department of BIN Convergence Technology,Chonbuk National University

References (29)

Show source-provided references
1. [1] J. H. Nichols, C. Howard, L. Kimberly, C. Miller, D. Nyberg, Am J Clin. Pathol. 103, 244 (1995).10.1093/ajcp/103.2.244 ↗
2. [2] V.T. Innanen, F.B. de Campos, Clin. Chem. 41, 1537 (1995).10.1093/clinchem/41.10.1537 ↗
3. [3] A. Aynsley-Green, J Pediatr. Child Health. 27,21 (1991).10.1111/j.1440-1754.1991.tb00340.x ↗
4. [4] K. Hussain, N. Sharieff , Early Human Dev. 57, 121 (2000).10.1016/S0378-3782(99)00060-2 ↗
5. [5] K. Weiner, Diabet. Med. 8, 172 (1991).10.1111/j.1464-5491.1991.tb01566.x ↗
6. [6] R. F. Louie, Z. Tang, D. V. Sutton, J. H. Lee, G. J. Kost, Arch. Pathol. Lab. Med. 124, 257 (2000).10.5858/2000-124-0257-POCGT ↗
7. [7] Z. Tang, J. H. Lee, R. F. Louie, G. J. Kost, Arch. Pathol. Lab. Med. 124, 1135 (2000).10.5858/2000-124-1135-EODHLO ↗
8. [8] Pathol. Lab. Med. 124Z. Tang, R. F. Louie, J. H. Lee, D. M. Lee, E. Earl, G. J.Kost, Crit. Care Med. 29, 1062 (2001).10.1097/00003246-200105000-00038 ↗
9. [9] C. A. Finch, Poly(vinyl alcohol) Development, Ch. 1, John Wiley & Sons Ltd, Chichester, UK (1992).
10. [10] E. Chiellini, A. Corti, S. DʼAntone, R. Solaro, Prog. Polym. Sci. 28, 963 (2003).10.1016/S0079-6700(02)00149-1 ↗
11. [11] C. C. DeMerlis, D. R. Schoneker, Food Chem. Toxicol. 41, 319 (2003).10.1016/S0278-6915(02)00258-2 ↗
12. [12] J.C.Park,T.Ito,K.O.Kim,K.W.Kim,B.S.Kim, Toxicol. 41, 319 (2003). M.S. Khil, H. Y. Kim, I. S. Kim, Polymer Journal 42,273 (2010).10.1038/pj.2009.340 ↗
13. [13] N. J. Forrow, S. W. Bayliff , Biosensors and Bioelectronics 21, 581 (2005).10.1016/j.bios.2004.12.011 ↗
14. [14] E. Magner, Analyst 126, 861 (2001).10.1039/b009125l ↗
15. [15] S. Warren, T. McCormac, E. Dempsey, Bioelectrochemistry 67, 23 (2005).10.1016/j.bioelechem.2004.07.005 ↗
16. [16] E. S. Lee, D. Lei, K. Devarayan, B. S. Kim, Composites Science and Technology 110, 111 (2015).10.1016/j.compscitech.2015.02.001 ↗
17. [17] K. O. Kim, Y. A. Seo, B. S. Kim, K. J. Yoon, M. S. Khil, H. Y. Kim, I. S. Kim, Colloid Polym Sci. 289,863 (2011).10.1007/s00396-011-2407-y ↗
18. [18] K. Wei, Y. Li, K. O. Kim, Y. Nakagawa, B. S. Kim, K.Abe,G.Q.Chen,I.S.Kim, Journal of Biomedical Mater. Res. A 97A, 272 (2011).10.1002/jbm.a.33054 ↗
19. [19] K. O. Kim, B. S. Kim, K. H. Lee, Y. H. Park, I. S. Kim, J Mater Sci: Mater Med 24, 2029 (2013).10.1007/s10856-013-4943-0 ↗
20. [20] K. O. Kim, Y. Akada, W. Kai, B. S. Kim, I. S. Kim, Journal of Biomaterials and Nanobiotechnology 2, 353 (2011).10.4236/jbnb.2011.24044 ↗
21. [21] B. S. Kim, I. S. Kim, Polymer Reviews 51(3), 235 (2011).10.1080/15583724.2011.599507 ↗
22. [22] S. R. Lee, Y. T. Lee, K. Sawada, H. Takao, M. Ishida, Biosensors and Bioelectronics 24, 410 (2008).10.1016/j.bios.2008.04.017 ↗
23. [23] E. S. Lee, D. Lei, K. Devarayan, B. S. Kim, Composites Science and Technology 110, 111 (2015).10.1016/j.compscitech.2015.02.001 ↗
24. [24] J. Cui, D. Sun, S. Chen, W. Zhou, P. Hu, H. Liu, Z. Huang, J. Mater. Chem.. 21, 10633 (2011).10.1039/c1jm11805f ↗
25. [25] ISO 15197, http://www.iso.org/iso/home.htm (2003).
26. [26] A. Manz, H. Becker, Topics in Current Chemistry p.194, 215, Springer- Verlag, Heidelberg (1998).
27. [27] The glucose biosensor of PVA/PAA-GOD coated nanofibers on a Copper/Ni electrode described here has a low sensitivity to hematocrit levels.
28. [28] The sensor exhibits a relatively short response time, approximately 3 s and low electrical resistance, less than 0.01 Ω.
29. [29] The sensor has excellent reproducibility with a correlation coefficient of 0.9924 and a total nonlinearity error of 2.15%.