journal article·1991-01-01

Fracture Toughness JIC Prediction From Super-Small Specimens (0.2CT, 0.5MM Thick) of a Martensitic Stainless Steel HT-9

Xingyuan Mao

Publisher page

Abstract

The fracture toughness of alloy HT-9, a martensitic stainless steel under consideration for fusion reactor applications, was determined from 0.2CT (0.5mm thick) specimens. Specimens with thicknesses of 25 (1CT), 10 (0.4CT), 3 and 0.5 (0.2CT)mm were tested to investigate the effects of specimen size on fracture toughness. 0.2CT (0.5mm thick) specimens did not satisfy ASTM E813 size requirements for a valid JIc. Fractographic examinations of the variation of stretch zone width and fracture modes along the specimen thickness were performed by scanning electron microscopy (SEM), where flat and shear fracture regions had been distinguished. A new JIc evaluation procedure for invalid specimen size is proposed using rigid plastic analysis and shear fracture measurements with fractographic observations. Predicted JIc values were compared with the JIc values obtained from valid specimen sizes. This miniaturized specimen technique may be applicable to post-irradiation fracture toughness testing.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fusion materials and technologies · Microstructure and Mechanical Properties of Steels · Hydrogen embrittlement and corrosion behaviors in metals

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanical Engineering, University of Calgary, Calgary, Alberta, Canada T2N 1N4

References