Powder Bed Fusion Versus Material Extrusion: A Comparative Case Study on Polyether-Ether-Ketone Cranial Implants
Source abstract
Abstract
As the choice of additive manufacturing (AM) technologies is becoming wider with reliable processes and a wider range of materials, the selection of the right technology to fabricate a certain product is becoming increasingly difficult from a technical and cost perspective. In this study polyether-ether-ketone cranial implants were manufactured by two AM techniques: powder bed fusion (PBF) and fused filament fabrication (FFF) and their dimensional accuracy, compression performance, and drop tower impact behavior were evaluated and compared. The results showed that both types of specimens differed from the original computer-aided design; although the origin of the deviation was different, the PBF samples were slightly inaccurate owing to the printing process where the accuracy of the FFF samples was influenced by postprocessing and removal of the scaffolds. The cranial implants fabricated using the FFF method absorbed more energy during the compression and impact tests in comparison with the PBF process. The failure mechanisms revealed that FFF samples have a higher ability to deform and a more consistent failure mechanisms, with the damage localized around the puncture head region. The brittle nature of the PBF samples, a feature observed with other polymers as well, led to complete failure of the cranial implants into several pieces.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Additive Manufacturing and 3D Printing Technologies · Bone Tissue Engineering Materials · 3D Printing in Biomedical Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Engineering, College of Engineering, Mathematics and Physical Sciences, University of Exeter, Exeter, United Kingdom.
References (24)
Show source-provided references
1. 10.1016/j.biomaterials.2007.07.01310.1016/j.biomaterials.2007.07.013 ↗
2. 10.1016/j.colsurfb.2018.05.02710.1016/j.colsurfb.2018.05.027 ↗
3. 10.1016/S0142-9612(03)00028-010.1016/S0142-9612(03)00028-0 ↗
4. 10.1016/j.matdes.2017.10.07810.1016/j.matdes.2017.10.078 ↗
5. 10.1016/j.actbio.2014.11.03010.1016/j.actbio.2014.11.030 ↗
6. 10.1016/B978-1-4377-4463-7.10012-010.1016/B978-1-4377-4463-7.10012-0 ↗
7. 10.1016/j.addma.2021.10184310.1016/j.addma.2021.101843 ↗
8. 10.1016/j.eurpolymj.2015.04.00310.1016/j.eurpolymj.2015.04.003 ↗
9. 10.1002/jbm.b.3119810.1002/jbm.b.31198 ↗
10. 10.1016/j.polymertesting.2018.08.00810.1016/j.polymertesting.2018.08.008 ↗
11. 10.1016/j.jmbbm.2011.05.03910.1016/j.jmbbm.2011.05.039 ↗
12. Sharma N, , Honigmann P, , Cao S, et al. Dimensional characteristics of FDM 3D printed PEEK implant for craniofacial reconstructions. Trans Addit Manuf Meets Med, 2020; 2.
13. 10.3390/jcm909281810.3390/jcm9092818 ↗
14. 10.3390/ijms2216852110.3390/ijms22168521 ↗
15. 10.1016/j.jmapro.2020.04.06310.1016/j.jmapro.2020.04.063 ↗
16. 10.1016/j.jbiomech.2009.05.03010.1016/j.jbiomech.2009.05.030 ↗
17. 10.1016/j.compscitech.2009.02.02910.1016/j.compscitech.2009.02.029 ↗
18. 10.1016/j.jcomc.2020.10002910.1016/j.jcomc.2020.100029 ↗
19. Hamada H, , Ramakrishna S. Comparison of static and impact energy absorption of carbon fiber/PEEK composite tubes. In: Composite Materials: Testing and Design: Twelfth Volume, ASTM International, 1996.
20. 10.1089/neu.2011.179410.1089/neu.2011.1794 ↗
21. 10.1016/j.compstruct.2015.08.09010.1016/j.compstruct.2015.08.090 ↗
22. 10.1097/00001665-200405000-0001210.1097/00001665-200405000-00012 ↗
23. 10.1007/s00170-018-2338-610.1007/s00170-018-2338-6 ↗
24. 10.1016/j.jmbbm.2020.10370110.1016/j.jmbbm.2020.103701 ↗