Multifunctional glycoprotein coatings improve the surface properties of highly oxygen permeable contact lenses
Source abstract
Abstract
To achieve and maintain good operability of medical devices while reducing putative side effects for the patient, a promising strategy is to tailor the surface properties of such devices as they critically dictate the tissue compatibility and the biofouling behavior. Indeed, those properties can be strongly improved by generating mucin coatings on such medical devices. However, using coatings on optical systems, e.g., contact lenses, comes with various challenges: here, the geometrical and optical characteristics of the lens may not be compromised by either the coating process or the coating itself. In this study, we show how mucin macromolecules can be attached onto the surfaces of rigid, gas permeable contact lenses while maintaining all critical lens parameters. We demonstrate that the generated coatings improve the surface wettability (contact angles are reduced from 105° to 40° and liquid film break-up times are increased from <1 s to 31 s) and prevent tribological damage to corneal tissue. Additionally, such coatings are highly transparent (transmission values above 98 % compared to an uncoated sample are reached) and efficiently reduce lipid deposition to the lens surface by 90 % but fully maintain the geometrical and mechanical properties of the lenses. Thus, such mucin coatings could also be highly beneficial for other optical systems that are used in direct contact with tissues or body fluids.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Ocular Surface and Contact Lens · Advanced Drug Delivery Systems · Corneal surgery and disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (71)
Show source-provided references
1. Nanoporous gold-based biofuel cells on contact lenses10.1021/acsami.7b18708 ↗
2. Nanofibrillar poly (vinyl alcohol) ionic organohydrogels for smart contact lens and human-interactive sensing10.1021/acsami.0c06263 ↗
3. Intelligent wireless theranostic contact lens for electrical sensing and regulation of intraocular pressure
4. A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure10.1038/s41551-021-00719-8 ↗
5. An ultrasensitive contact lens sensor based on self-assembly graphene for continuous intraocular pressure monitoring10.1002/adfm.202010991 ↗
6. Thapsigargin-coated intraocular lenses inhibit human lens cell growth10.1038/nm0997-1026 ↗
7. Smart contact lens and transparent heat patch for remote monitoring and therapy of chronic ocular surface inflammation using mobiles10.1126/sciadv.abf7194 ↗
8. Lab-on-a-contact lens: recent advances and future opportunities in diagnostics and therapeutics
9. Multiple drug delivery from the drug-implants-laden silicone contact lens: addressing the issue of burst drug release10.1016/j.msec.2020.110885 ↗
10. The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on epidemiology10.1167/iovs.13-13125 ↗
11. Estimates of incidence and prevalence of visual impairment, low vision, and blindness in the United States10.1001/jamaophthalmol.2017.4655 ↗
12. Contact lens correction of aphakia in children: a report by the American Academy of ophthalmology10.1016/j.ophtha.2018.03.014 ↗
13. Quantitative measurement of interocular suppression in anisometropic amblyopia: a case-control study10.1016/j.ophtha.2013.01.048 ↗
14. Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery10.1016/j.clae.2020.04.009 ↗
15. Persistent corneal epithelial defects: a review article
16. Management of irregular astigmatism with rigid gas permeable contact lenses
17. Clinical evaluation of large diameter rigid-gas permeable versus soft toric contact lenses for the correction of refractive astigmatism. A multicenter study10.1097/ICL.0000000000000323 ↗
18. Effect of rigid gas permeable contact lens on keratoconus progression: a review10.18240/ijo.2020.07.17 ↗
19. Clinical evaluation of different types of contact lenses in keratoconus management10.1016/j.clae.2019.02.013 ↗
20. Contact lens-related complications: a review
21. Association between contact lens discomfort and pre-lens tear film kinetics10.1097/OPX.0000000000000866 ↗
22. The TFOS International Workshop on Contact Lens Discomfort: report of the contact lens interactions with the ocular surface and adnexa subcommittee10.1167/iovs.13-13187 ↗
23. Trends in contact lens microbial keratitis 1999 to 2015: a retrospective clinical review10.1111/ceo.13484 ↗
24. Development of silicone hydrogel antimicrobial contact lenses with Mel4 peptide coating10.1097/OPX.0000000000001282 ↗
25. Novel poly (vinylpyrrolidone)-coated silicone contact lenses to improve tear volume during lens wear: in vitro and in vivo studies10.1021/acsomega.0c01764 ↗
26. Engineering and development of chitosan-based nanocoatings for ocular contact lenses10.1016/j.xphs.2018.11.036 ↗
27. Mucin structure, aggregation, physiological functions and biomedical applications10.1016/j.cocis.2005.11.001 ↗
28. Distribution of sialic acids on mucins and gels: a defense mechanism10.1016/j.bpj.2011.08.058 ↗
29. Charged glycan residues critically contribute to the adsorption and lubricity of mucins10.1016/j.colsurfb.2019.110614 ↗
30. Modulating mucin hydration and lubrication by deglycosylation and polyethylene glycol binding10.1002/admi.201500308 ↗
31. Structure, function and gene expression of epithelial mucins10.1177/030089169708300301 ↗
32. The structure and assembly of secreted mucins10.1074/jbc.274.45.31751 ↗
33. Tear film mucins: front line defenders of the ocular surface; comparison with airway and gastrointestinal tract mucins10.1016/j.exer.2013.07.027 ↗
34. The tear film and ocular mucins10.1111/j.1463-5224.2004.00325.x ↗
35. Distribution of mucins at the ocular surface10.1016/S0014-4835(03)00204-5 ↗
36. Mucin biopolymers as broad-spectrum antiviral agents10.1021/bm3001292 ↗
37. Covalent mucin coatings form stable anti-biofouling layers on a broad range of medical polymer materials10.1002/admi.201902069 ↗
38. Macromolecular coatings enhance the tribological performance of polymer-based lubricants10.1002/admi.201900366 ↗
39. Highly transparent covalent mucin coatings improve the wettability and tribology of hydrophobic contact lenses10.1021/acsami.0c06847 ↗
40. An improved, filtration-based process to purify functional mucins from mucosal tissues with high yields
41. Structural alterations of mucins are associated with losses in functionality10.1021/acs.biomac.1c00073 ↗
42. Mucin structure, aggregation, physiological functions and biomedical applications10.1016/j.cocis.2005.11.001 ↗
43. Transmission electron microscopy studies on pig gastric mucin and its interactions with chitosan10.1016/0144-8617(95)00105-0 ↗
44. High-speed camera characterization of voluntary eye blinking kinematics10.1098/rsif.2013.0227 ↗
45. Reversible condensation of mucins into nanoparticles10.1021/acs.langmuir.8b02190 ↗
46. Smart biopolymer-based multi-layers enable consecutive drug release events on demand10.1002/admi.202000735 ↗
47. A simple accurate formula for calculating saturation vapor pressure of water and ice10.1175/JAMC-D-17-0334.1 ↗
48. Tailoring surfaces with silanes
49. Nature of adhesion through silane coupling agents
50. Mucin gel assembly is controlled by a collective action of non-mucin proteins, disulfide bridges, Ca2+-mediated links, and hydrogen bonding10.1038/s41598-018-24223-3 ↗
51. Contour length and refolding rate of a small protein controlled by engineered disulfide bonds10.1529/biophysj.106.091561 ↗
52. Surface-functionalized model contact lenses with a bioinspired proteoglycan 4 (PRG4)-grafted layer10.1021/acsami.8b09755 ↗
53. The relationship between contact lens oxygen permeability and binding of Pseudomonas aeruginosato human corneal epithelial cells after overnight and extended wear
54. The effect of contact lens thickness and corneal toricity on flexure and residual astigmatism10.1097/00006324-197204000-00002 ↗
55. Flexure and residual astigmatism with RGP lenses of low, medium, and high oxygen permeability10.1016/S0892-8967(99)00009-7 ↗
56. Fabrication of hydrophilic surface on rigid gas permeable contact lenses to enhance the wettability using ultraviolet laser system10.3390/mi10060394 ↗
57. The nature of normal blinking patterns10.1111/j.1755-3768.1982.tb03034.x ↗
58. Effects of sterilization methods on the integrity and functionality of covalent mucin coatings on medical devices10.1002/admi.202101716 ↗
59. A novel method to predict the dry eye symptoms in new contact lens wearers10.1097/OPX.0b013e3181b598cd ↗
60. Targeting contact lens induced dryness and discomfort: what properties will make lenses more comfortable10.1097/OPX.0b013e31804636af ↗
61. The ocular surface and tear film and their dysfunction in dry eye disease10.1016/S0039-6257(00)00203-4 ↗
62. Interactions of eyelids and tears in corneal wetting and the dynamics of the normal human eyeblink10.1016/0002-9394(80)90058-6 ↗
63. Loss of cartilage structure, stiffness, and frictional properties in mice lacking PRG410.1002/art.27436 ↗
64. Comparison of friction and wear of articular cartilage on different length scales10.1016/j.jbiomech.2015.07.027 ↗
65. Influence of surface wettability on friction and wear tests10.1016/S0043-1648(98)00256-7 ↗
66. The statistical correlation of the coefficient of friction and wear rate of PTFE composites with steel counterface roughness and hardness10.1016/S0043-1648(02)00029-7 ↗
67. Surface roughness effect on the friction and wear of bulk metallic glasses10.1016/j.wear.2014.11.030 ↗
68. Wetting behavior and stability of surface-modified polyurethane materials10.1002/ppap.202100126 ↗
69. In vitro and in vivo evaluation of the antibacterial properties of a nisin-grafted hydrated mucin multilayer film10.1016/j.polymertesting.2016.12.006 ↗
70. Covalent mucin coatings form stable anti-biofouling layers on a broad range of medical polymer materials10.1002/admi.201902069 ↗
71. Several sterilization strategies maintain the functionality of mucin glycoproteins10.1002/mabi.202000090 ↗