Powering the heart: fully bioresorbable epicardial pacing leads
Source abstract
Abstract
Conventional temporary epicardial pacing wires (TPWs) are widely used for postoperative pacing support but pose risks of several complications due to their non-biodegradable nature. Here we present a fully bioresorbable epicardial pacing lead composed of a pure zinc (Zn) core and a bioresorbable polymer insulation coating, fabricated using a simple and scalable dip-coating method. Zn-based leads demonstrated reliable pacing performance over a 4-week period in a rabbit model, comparable to clinical benchmarks. Comprehensive evaluations of their degradation behavior and tissue response in animal models revealed stable bioresorption and acceptable biocompatibility during and after the therapeutic period. This bioresorbable design eliminates the risks associated with non-degradable TPWs, while maintaining therapeutic efficacy and biocompatibility. With its unique combination of performance, safety, and adaptability, the Zn-polymer pacing lead represents a transformative step toward the next generation of TPWs, offering a safer and more effective alternative for managing postoperative cardiac pacing.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Cardiac pacing and defibrillation studies · Cardiac Arrhythmias and Treatments · Cardiomyopathy and Myosin Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Epicardial pacing to control arrhythmias following cardiac surgery10.1161/01.CIR.37.4S2.II-178 ↗
2. Implantable pacing lead technology10.1109/51.57868 ↗
3. F. S. Mubarak et al., Complications of epicardial pacing wire removal following adult cardiac surgery: a systematic review. Cureus 15: e49076.
4. Temporary epicardial pacing after cardiac surgery: a practical review10.1111/j.1365-2044.2007.04950.x ↗
5. Progressive dyspnea after CABG: complication of retained epicardial pacing wires10.1016/j.athoracsur.2008.03.013 ↗
6. Migration of retained epicardial pacing wires10.1093/eurheartj/ehw063 ↗
7. Bioresorbable molybdenum temporary epicardial pacing wires10.1016/j.actbio.2024.02.039 ↗
8. A soft and absorbable temporary epicardial pacing wire10.1002/adma.202101447 ↗
9. Evolution from bioinert to bioresorbable: in vivo comparative study of additively manufactured metal bone scaffolds10.1002/advs.202302702 ↗
10. Evolution of metallic cardiovascular stent materials: a comparative study among stainless steel, magnesium and zinc10.1016/j.biomaterials.2019.119641 ↗
11. Zinc-based alloys for degradable vascular stent applications10.1016/j.actbio.2018.03.005 ↗
12. Electrospun polycaprolactone (PCL) degradation: an in vitro and in vivo study10.3390/polym14163397 ↗
13. A 12-year experience of bipolar steroid-eluting epicardial pacing leads in children10.1016/j.athoracsur.2008.02.016 ↗
14. Virtual electrode theory explains pacing threshold increase caused by cardiac tissue damage10.1152/ajpheart.00637.2003 ↗
15. The electrode-tissue interface: the revolutionary role of steroid elution
16. Evolution of the degradation mechanism of pure zinc stent in the one-year study of rabbit abdominal aorta model10.1016/j.biomaterials.2017.08.022 ↗
17. Corrosion characteristics dictate the long-term inflammatory profile of degradable zinc arterial implants10.1021/acsbiomaterials.6b00591 ↗
18. Hybrid zinc oxide nanocoating on titanium implants: controlled drug release for enhanced antibacterial and osteogenic performance in infectious conditions10.1016/j.actbio.2024.09.039 ↗
19. Unveiling the governing role of ‘remodeling triangle area’ in soft-hard tissue interface equilibrium for metal implants advancement
20. Plasmatic urea nitrogen in growing rabbits with different combinations of dietary levels of lysine, sulphur amino acids and threonine
21. The implantable cardioverter-defibrillator lead: principles, progress, and promises10.1111/j.1540-8159.2009.02492.x ↗
22. Feasibility and efficacy of left bundle branch area pacing in patients indicated for cardiac resynchronization therapy10.1093/europace/euaa271 ↗
23. Fatigue and fracture of wires and cables for biomedical applications10.1080/09506608.2016.1152347 ↗
24. Criteria for the selection of materials for implanted electrodes10.1114/1.1581292 ↗
25. Investigation of factors influencing the hydrolytic degradation of single PLGA microparticles10.1016/j.polymdegradstab.2015.04.025 ↗
26. Accessing the biocompatibility of layered double hydroxide by intramuscular implantation: histological and microcirculation evaluation10.1038/srep30547 ↗