Generation and simulated imaging of pseudo-scaffolds to aid characterisation by X-ray micro CT
Source abstract
Abstract
In order to assess the suitability of polymer tissue scaffolds for use in regenerative medicine, methods to characterise scaffolds are needed. This requires the scaffold's structure to be determined for which X-ray microscopic computed tomography (X-ray micro CT) is widely used. However, because scaffolds are generally made of materials with low X-ray attenuating properties the images produced are far from ideal, which makes distinguishing scaffold material from the pores within it a non-trivial process. This paper presents a method for generating computer-simulated scaffolds that resemble the form of foamed polymer tissue scaffolds. Virtual images of the scaffold are then produced via a simulated X-ray micro CT process enabling the effect of varying the key parameters in the imaging process to be investigated. Here this is assessed via the calculated porosity of the sample, this being a simple measure of a scaffold's properties. Results highlight the difficulties in using X-ray micro CT to characterise scaffolds constructed from materials with low X-ray attenuating properties and suggest strategies that may be adopted in order to improve the quality of the images produced.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced X-ray and CT Imaging · Anatomy and Medical Technology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. A comparison of micro CT with other techniques used in the characterization of scaffolds10.1016/j.biomaterials.2005.08.035 ↗
2. Analysis of 3-D microstructure of porous poly(lactide-glycolide) matrices using confocal microscopy10.1002/(SICI)1097-4636(199823)43:3<291::AID-JBM10>3.0.CO;2-J ↗
3. Meeting the needs of monitoring in tissue engineering10.2217/17460751.2.2.145 ↗
4. Image-based characterization of foamed polymeric tissue scaffolds10.1088/1748-6041/3/1/015011 ↗
5. Resolution dependency of microstructural properties of cancellous bone based on three-dimensional μ-tomography10.3233/THC-1996-4112 ↗
6. Impact of spatial resolution on the prediction of trabecular architecture parameters10.1016/S8756-3282(98)00031-3 ↗
7. Analysis of the influence of image resolution on the discriminating power of trabecular bone architectural parameters10.1016/j.bone.2003.10.002 ↗
8. Effect of voxel size on 3D micro-CT analysis of cortical bone porosity10.1007/s00223-005-0274-6 ↗
9. Practical cone-beam algorithm10.1364/JOSAA.1.000612 ↗
10. Practical cone-beam algorithm10.1109/42.241876 ↗
11. ASTM · 2006
12. Natterer · 2001
13. Evans · 1955
14. Computerized tomography with X-ray, emission, and ultrasound sources10.1109/PROC.1979.11440 ↗
15. Cross-section reconstruction with a fan-beam scanning geometry10.1109/TC.1977.1674815 ↗
16. A threshold selection method from gray level histograms10.1109/TSMC.1979.4310076 ↗