Abstract

Using a custom-built, implantable pulse generator, we studied the effects of small pulsed currents on the viability on rat aortic-derived cells (RAOC) in vitro. The pulsed currents (0.37A/m(2)) underwent apoptosis within 24h as shown by the positive staining for cleaved caspase-3 and classically apoptotic morphology. Based on these findings, we examined the effects of nanocurrents in vivo. The pulse generator was implanted subcutaneously in the rat model. The electrode|tissue interface histology revealed no difference between the active platinum surface and the neighboring control surface, however we found a large difference between electrodes that were functional during the entire experiment and non-active electrodes. These non-active electrodes showed an increase in impedance at higher frequencies 21 days post-implantation, whereas working electrodes retained their impedance value for the entire experiment. These results indicate that applied currents can reduce the impedance of implanted electrodes.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Neuroscience and Neural Engineering · 3D Printing in Biomedical Research · Planarian Biology and Electrostimulation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. Implantable cardiac electrostimulation devices
2. Implantable bioelectronic interfaces for lost nerve functions10.1016/S0301-0082(98)00013-6 ↗
3. Neuropsychiatry: rewiring faulty circuits in the brain10.1126/science.323.5921.1554 ↗
4. Microsensors and microbiosensors for retinal implants10.2741/1518 ↗
5. Brain-machine interfaces: past, present and future10.1016/j.tins.2006.07.004 ↗
6. The application of implant technology for cybernetic systems10.1001/archneur.60.10.1369 ↗
7. Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve10.1109/TBME.2003.820321 ↗
8. A model of safe levels for electrical stimulation10.1109/10.126616 ↗
9. Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation10.1109/10.102812 ↗
10. Damage in peripheral nerve from continuous electrical stimulation: comparison of two stimulus waveforms10.1007/BF02446202 ↗
11. Electrical stimulation of excitable tissue: design of efficacious and safe protocols10.1016/j.jneumeth.2004.10.020 ↗
12. Cellular and molecular dynamics in the foreign body reaction10.1089/ten.2006.12.1955 ↗
13. Biomaterials: where we have been and where we are going10.1146/annurev.bioeng.6.040803.140027 ↗
14. Chronic response of adult rat brain tissue to implants anchored to the skull10.1016/j.biomaterials.2003.09.010 ↗
15. Current problems and potential techniques in in vivo glucose monitoring10.1023/B:JOFL.0000039339.36839.19 ↗
16. Electrical properties of implant encapsulation tissue10.1007/BF02368219 ↗
17. Self-assembled monolayers of polythiophene conductive polymers improve biocompatibility and electrical impedance of neural electrodes10.1016/j.bios.2006.08.011 ↗
18. Conducting polymers for neural interfaces: challenges in developing an effective long-term implant10.1016/j.biomaterials.2008.04.047 ↗
19. Response of brain tissue to chronically implanted neural electrodes10.1016/j.jneumeth.2005.08.015 ↗
20. Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances10.1109/TNSRE.2005.847373 ↗
21. Influence of applied currents on the viability of cells close to microelectrodes10.1039/B814237H ↗
22. Electrical wound-healing assay for cells in vitro10.1073/pnas.0307588100 ↗
23. The biochemistry of apoptosis
24. Corpse clearance defines the meaning of cell death10.1038/35037722 ↗
25. Apoptosis: a relevant tool for anticancer therapy10.1093/annonc/mdl963 ↗
26. Electrochemical treatment of tumours10.1016/S0302-4598(99)00073-2 ↗
27. Induction of apoptotic cell death by direct-current treatment in human leukemic cell lines10.1007/BF01240119 ↗
28. Theory of electroporation: a review10.1016/S0302-4598(96)05062-3 ↗
29. Skin electroporation for transdermal and topical delivery10.1016/j.addr.2003.10.027 ↗
30. Electric field pulses can induce apoptosis10.1007/s002329900522 ↗
31. Apoptotic and necrotic cell death are both induced by electroporation in HL60 human promyeloid leukaemia cells10.1023/A:1026497306006 ↗
32. Low voltage pulses can induce apoptosis10.1016/j.canlet.2008.04.019 ↗
33. Electrical stimulation of wound healing10.1046/j.1523-1747.2003.12454.x ↗
34. Direct current electrical fields induce apoptosis in oral mucosa cancer cells by NADPH oxidase-derived reactive oxygen species10.1002/bem.20361 ↗
35. Electrically controlling cell adhesion, growth and migration10.1016/j.colsurfb.2010.04.019 ↗
36. The morphology of apoptosis10.1007/s004410000193 ↗
37. Down-regulation of vinculin upon MK886-induced apoptosis in LN18 glioblastoma cells
38. Active caspase-3 and ultrastructural evidence of apoptosis in spontaneous and induced cell death in bovine in vitro produced pre-implantation embryos10.1002/mrd.20714 ↗
39. Fluorescence interferometry of neuronal cell adhesion on microstructured silicon10.1103/PhysRevLett.81.5241 ↗
40. An interaction between vinculin and talin10.1038/308744a0 ↗
41. Common principles in cell adhesion10.1006/excr.1996.0243 ↗
42. Distinct modes of cell death induced by different reactive oxygen species: amino acyl chloramines mediate hypochlorous acid-induced apoptosis10.1074/jbc.M200212200 ↗
43. Feasibility study of an online toxicological sensor based on the optical waveguide technique10.1016/S0956-5663(00)00102-0 ↗
44. Geometric control of cell life and death10.1126/science.276.5317.1425 ↗
45. Evidence for growth inhibition by platinum electrodes at low current levels10.1016/0141-5425(82)90069-3 ↗
46. Mass changes and dissolution of platinum during electrical stimulation in artificial perilymph solution10.1016/S0142-9612(00)00146-0 ↗