The use of trans-vinylene formation in quantifying the spatial distribution of electron beam penetration in polyethylene. Single-sided, double-sided and shielded irradiation
Source abstract
Abstract
The use of the quantification of trans-vinylene unsaturations in irradiated ultrahigh molecular weight polyethylene (UHMWPE) in determining the spatial distribution of electron beam penetration was investigated. UHMWPE was irradiated with a 10MeV linear electron beam accelerator to 100kGy at both room temperature and 125 degrees C in air. The irradiation was carried out in shielded and unshielded single-sided and unshielded double-sided irradiation modes. Dose-depth profiles were measured by quantifying the yields of trans-vinylene unsaturations as a function of depth away from the e-beam incidence surfaces using infrared spectroscopy. The extent of beam penetration increased with increasing irradiation temperature as was manifested by the increase in the iso-dose penetration with the unshielded single-sided irradiation and increased dose overlap with the unshielded double-sided irradiation. The optimum thickness with maximum uniformity in dose-depth distribution for double-sided irradiation was 85 and 90mm for 25 degrees C and 125 degrees C irradiation temperatures, respectively.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Injection Molding Process and Properties · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. Development of an extremely wear resistant ultra-high molecular weight polyethylene for total hip replacements10.1002/jor.1100170203 ↗
2. Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)10.1016/S0142-9612(99)00039-3 ↗
3. A novel method of crosslinking UHMWPE to improve wear, reduce oxidation and retain mechanical properties10.1054/arth.2001.20540 ↗
4. E1649-00 Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300keV and 25MeV. American Society of Testing and Materials International: West Conshohocken, PA, USA, 2000.
5. High-density polyethylene dosimetry by transvinylene FTIR analysis10.1016/S0969-806X(99)00324-2 ↗
6. Identification and quantification of irradiation in UHMWPE through trans-vinylene yield10.1002/1097-4636(20010915)56:4<584::AID-JBM1131>3.0.CO;2-Y ↗
7. The radiation chemistry of polyethylene. IX. Temperature coefficient of crosslinking and other effects10.1021/ja00985a002 ↗
8. Irradiation of ultrahigh-molecular-weight polyethylene10.1002/pol.1985.180230819 ↗
9. Effects of vinyl chain-ends on the melt viscoelastic properties of radiation crosslinked polyethylene10.1177/875608799200800105 ↗
10. Radiolytic Formation and Decay of Trans-Vinylene Unsaturation in Polyethylene
11. Radiolytic formation and decay of trans-vinylene unsaturation in polyethylene10.1016/0969-806X(95)00271-X ↗