Abstract

Two self-reinforced poly(desamino tyrosyl-tyrosine ethyl ester carbonate), poly(DTE carbonate) or self-reinforced poly(DTE carbonate)/bioactive glass rods, (2 mm by 40 mm) were implanted into the dorsal subcutaneous tissue and osteotomies of the distal femur were fixed with these rods (2 mm by 26 mm) in 36 rabbits. The follow-up times varied from three to 100 weeks. After sacrifice, three-point bending and shear tests and molecular weight measurements were performed for subcutaneously placed rods. Radiological, histological, histomorphometrical, microradiographic, and oxytetracycline-fluorescence studies of the osteotomized and intact control femora were performed. The initial mechanical properties were higher with the SR-poly(DTE carbonate) rods, but the SR-poly(DTE carbonate)/bioactive glass rods lost their mechanical properties slower. At 100 weeks the bending strength had decreased to 21% of the initial value with the SR-poly(DTE carbonate) rods and to 49% with the SR-poly(DTE carbonate)/bioactive glass rods. The shear strength had decreased to 10% with the SR-poly(DTE carbonate) rods and to 23% of the initial value with the SR-poly(DTE carbonate)/bioactive glass rods. Two slight displacements and one delayed union and one failure of fixation were seen in the SR-poly(DTE carbonate) group. In the SR-poly(DTE carbonate)/bioactive glass group five delayed unions and seven slight displacements were seen. No signs of osteolysis or foreign body reactions were observed. Signs of resorption of the implants were seen at 100 weeks in the SR-poly(DTE carbonate)/bioactive glass group. The present investigation showed that the mechanical strength and fixation properties of SR-poly(DTE carbonate) and SR-poly(DTE carbonate)/bioactive glass rods are suitable for fixation of cancellous bone osteotomies in rabbits.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. The future of biodegradable osteosyntheses10.1089/107632700418119 ↗
2. Biodegradable implants in traumatology10.1007/BF00443385 ↗
3. Biodegradable pin fixation of elbow fractures in children10.1302/0301-620X.73B6.1659570 ↗
4. The effect of a penetrating biodegradable implant on the epiphyseal plate10.1097/01241398-198707000-00007 ↗
5. Biodegradable implants in fracture fixation10.1016/S0140-6736(85)91847-1 ↗
6. Absorbable implants in the fixation of fractures
7. Bioabsorbable fixation in orthopaedic surgery and traumatology10.1016/S0142-9612(00)00128-9 ↗
8. Body-absorbable osteosynthesis devices10.1016/0267-6605(91)90019-C ↗
9. Bioabsorbable osteosynthetic implants of ultra high strength poly L-lactide
10. Shear-load carrying capacities of the distal rat femora after osteotomy fixed with self-reinforced polyglycolic acid and poly-l-lactic acid pins
11. Absorption, biocompatibility, and fixation properties of polylactic acid in bone tissue
12. Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies10.2106/00004623-199274070-00008 ↗
13. Tissue reaction of bioabsorbable ultra high strength poly(l-lactide) rod
14. Totally bioresorbable composites systems for internal fixation of bone fractures
15. Biodegradable self-reinforced composite materials; manufacturing, structure and mechanical properties10.1016/0267-6605(92)90081-4 ↗
16. Fixation of distal femoral osteotomies with self-reinforced poly(desamino tyrosyl-tyrosine ethyl ester carbonate) rods10.1007/s007760200098 ↗
17. Comparative histological evaluation of new tyrosine-derived polymers and poly(l-lactic acid) as a function of polymer degradation10.1002/(SICI)1097-4636(19980905)41:3<443::AID-JBM14>3.0.CO;2-J ↗
18. Direct chemical bond of bioactive glass–ceramic materials to bone and muscle10.1002/jbm.820070304 ↗
19. Subchondral bone and cartilage repair with bioactive glasses, hydroxyapatite, and hydroxyapatite-glass composite10.1002/(SICI)1097-4636(199612)32:4<543::AID-JBM7>3.0.CO;2-R ↗
20. Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation10.1302/0301-620X.78B3.0780369 ↗
21. Soft tissue reactions of different biodegradable polylactide implants10.1016/S0142-9612(03)00496-4 ↗
22. Canine bone response to tyrosine-derived polycarbonates and poly(l-lactic acid)10.1002/(SICI)1097-4636(199605)31:1<35::AID-JBM5>3.0.CO;2-R ↗
23. Shear strength of cancellous bone after osteotomy fixed with absorbable self-reinforced polyglycolic acid and poly-l-lactic acid rods
24. Bone formation in rabbit cancellous bone defects filled with bioactive glass granules10.3109/17453679508995588 ↗
25. Small changes in polymer chemistry have a large effect on the bone-implant interface10.1016/S0142-9612(99)00151-9 ↗