journal article·2005-11

Peripheral quantitative computed tomography in evaluation of bioactive glass incorporation with bone

Ville-Valtteri Välimäki, Niko Moritz, Jessica J. Yrjans, Michel Dalstra, Hannu T. Aro

Biomaterials· Volume 26· Issue 33
Publisher page

Abstract

This laboratory study examined the feasibility of non-invasive, in vivo peripheral quantitative computed tomography (pQCT) method in evaluation of bioactive glass incorporation with bone. An intramedullary defect model of the rat tibia was applied. The defect was filled with bioactive glass microspheres (diameter of 250-315 microm) or was left to heal without filling (empty controls). The results of the pQCT analysis were compared with those of histomorphometry. In the control defects, there was a good correlation (r2 = 0.776, p < 0.001) between the pQCT density of the intramedullary space and the amount of new bone measured by histomorphometry. In the defects filled with bioactive glass, the use of thresholding techniques of the applied pQCT system (Stratec XCT Research M) failed in separation of new bone formation and bioactive glass particles. However, detailed analysis of the pQCT attenuation profiles showed time-related changes which well matched with the histomorphometric results of new bone formation both in control and bioactive glass filled defects. The biphasic pQCT attenuation profiles of bioactive glass filled defects could be separated into two distinct peaks. In statistical analysis of various variables, the center (i.e. the value of attenuation) of the major attenuation peak was found to be the most significant indicator of the incorporation process. The center of the peak initially decreased (during the first 4 weeks of healing) and thereafter increased. These two phases probably reflect the primary resorption and reactivity of the bioactive glass microspheres in vivo followed by secondary new bone formation on their surfaces. Based on these results, pQCT-method seems to be suitable for in vivo follow-up of the bioactive glass incorporation processes. Although the imaging technique is not able to discriminate the individual microspheres from invading new bone unambiguously, the attenuation profiling seems to give adequate information about the state of the incorporation process. This information may help to establish non-invasive imaging techniques of synthetic bone substitutes for preclinical and clinical testing of their efficacy.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Radiography and Imaging · Facial Trauma and Fracture Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. Substitutes for autologous bone graft in orthopaedic trauma10.1302/0301-620X.83B1.0830003 ↗
2. Bone-grafting and bone-graft substitutes10.2106/00004623-200203000-00020 ↗
3. The role of growth factors in the repair of bone: biology and clinical applications10.2106/00004623-200206000-00022 ↗
4. Cortical and total bone mineral content of the radius: accuracy of peripheral computed tomography10.1016/8756-3282(96)00040-3 ↗
5. Accuracy and precision study in vitro for peripheral quantitative computed tomography10.1007/BF01622736 ↗
6. Differentiating between orchiectomized rats and controls using measurements of trabecular bone density: a comparison among DXA, histomorphometry, and peripheral quantitative computerized tomography10.1007/BF00298994 ↗
7. Precision and accuracy of peripheral quantitative computed tomography (pQCT) in the mouse skeleton compared with histology and microcomputed tomography (microCT)10.1359/jbmr.2003.18.8.1486 ↗
8. Morphometric analysis of noninvasively assessed bone biopsies: comparison of high-resolution computed tomography and histologic sections10.1016/8756-3282(95)00489-0 ↗
9. Comparison of three-point bending test and peripheral quantitative computed tomography analysis in the evaluation of the strength of mouse femur and tibia10.1016/S8756-3282(98)00076-3 ↗
10. Impaction grafting with morsellised allograft and tricalcium phosphate-hydroxyapatite: incorporation within ovine metaphyseal bone defects10.1016/S0142-9612(02)00018-2 ↗
11. Molecular biologic comparison of new bone formation and resorption on microrough and smooth bioactive glass microspheres10.1002/jbm.b.10529 ↗
12. Välimäki V-V, Yrjans JJ, Vuorio E, Aro HT. Combined effect of bone morphogenetic protein-2 gene therapy and bioactive glass microspheres in enhancement of new bone formation. J Biomed Mater Res, in press.
13. Biologic significance of surface microroughing in bone incorporation of porous bioactive glass implants10.1002/jbm.a.10501 ↗
14. Bioglass 45S5 stimulates osteoblast turnover and enhances bone formation in vitro: implications and applications for bone tissue engineering10.1007/s002230001134 ↗
15. Biological applications of bioactive glasses
16. Processing of spherical bioactive glass particles10.1016/0021-8502(95)97323-7 ↗
17. Histomorphometric and molecular biologic comparison of bioactive glass granules and autogenous bone grafts in augmentation of bone defect healing10.1002/(SICI)1097-4636(199704)35:1<9::AID-JBM2>3.0.CO;2-S ↗
18. Analysis of 3D bone ingrowth into polymer scaffolds via micro-computed tomography imaging10.1016/j.biomaterials.2004.01.047 ↗