A comparative radiological assessment of polylactide pins over 3 years in vivo
Source abstract
Abstract
Biodegradable polylactide implants allow secure fixation of osteochondral fractures with minimal adverse effects. The goal of this prospective, randomized animal study was to show whether osteoconductive effects can be achieved through the development of poly-L/DL(70/30)lactide composite implants with 10% beta-tricalcium phosphate, and whether degradation can be positively influenced and adverse effects minimized using such implants. An additional goal was to clarify which radiological procedure is most suitable to observe the course of follow-up. Thirtysix medial femoral condyle osteotomies of sheep were fixed with either 3 poly-L/DL-lactide pins or 3 composite pins, and the pin canal widths were measured with conventional radiographs, with CT, MRI, and histologically after 3, 18, and 36 months. All fractures healed completely without displacement or clinically relevant complications. The pin canals dilated secondary to pin degradation at the 12th month, and then decreased in size later. At 36 months, the pins had microscopically disappeared, and the canals were filled with bone or scar tissue. There were no statistically significant differences between the pin-types. Poly-L/DL-lactide pins and composite C-pins are suitable for secure fixation of small osteochondral fractures. Osteoconductive effects of biocompatibility or osseous integration relating to composite development were not evident. Conventional radiography and computer tomography were suitable techniques for observation of pin canals. Due to frequently observed artifact, MRI was not suitable to observe the course of the implants.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone fractures and treatments · Orthopedic Surgery and Rehabilitation · Spine and Intervertebral Disc Pathology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Bioabsorbable implants10.1023/B:ABME.0000007802.59936.fc ↗
2. Bioabsorbable fixation in orthopaedic surgery and traumatology10.1016/S0142-9612(00)00128-9 ↗
3. Bioresorbable fracture fixation in orthopedics
4. Synthetic biodegradable implants in operative sports medicine. Current concept review10.1016/S0749-8063(00)90055-0 ↗
5. Causes of the clinical tissue response to polyglycolide and polylactide implants with an emphasis on the knee10.1007/s004020000221 ↗
6. Local foreign-body reactions to biodegradable implants—a classification system10.1007/s001130050172 ↗
7. Soft tissue reactions of different biodegradable polylactide implants10.1016/S0142-9612(03)00496-4 ↗
8. Foreign-body reaction and the course of osteolysis after Polyglycolide implants for fracture fixation10.1302/0301-620X.78B3.0780369 ↗
9. Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers10.1302/0301-620X.72B4.2199452 ↗
10. Biodegradable rods versus Kirschner wire fixation of wrist fractures10.1302/0301-620X.74B6.1332974 ↗
11. New developments in the application of biodegradable implants
12. In vitro and in vivo studies on bioabsorbable ultra-high-strength poly (l-lactide) rods10.1002/jbm.820261203 ↗
13. Tissue reaction of bioabsorbable ultra high strength oply (l-lactid) rod. A long term study in rabbits
14. A 5-year in vitro and in vivo study of the biodegradation of polylactide plates10.1016/S0278-2391(98)90461-X ↗
15. Healing of subcapital femoral steotomies fixed with self-reinforced poly-l-lactide screws10.1007/s00402-001-0379-y ↗
16. Transmission electron microscopic visualization of the degradation and phagocytosis of a poly-l-lactide screw in cancellous bone10.1002/jbm.10115 ↗
17. The long term behavior of poly-l-lactide screws in a minipig fracture model10.1002/jbm.10388 ↗
18. New bioresorbable pin for the reduction of small bony fragments10.1016/0142-9612(95)00327-4 ↗
19. In-vitro biocompatibility of bioresorbable polymers
20. Degradation behavior of Composite pins made of tricalcium phosphate and poly(l,dl-lactide) or the reduction of small bony fragments10.1163/156856201750180915 ↗
21. Gogolewski S. Bioresorbable polymers in trauma and bone surgery. Int J Care Injured 2000; 31: S-D28–D32.10.1016/S0020-1383(00)80020-0 ↗
22. Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/polyglycolic acid copolymers10.1016/0142-9612(96)85754-1 ↗
23. Adverse tissue reactions to bioabsorbable fixation devices10.1097/00003086-200002000-00026 ↗
24. Late degradation tissue response to poly(l-lactide) bone plates and screws10.1016/0142-9612(95)91092-D ↗
25. Bioabsorbable implants in orthopaedics10.5435/00124635-200109000-00001 ↗
26. Bone bonding ability of a new biodegradable composite for internal fixation of bone fractures10.1097/00003086-200010000-00030 ↗
27. Histomorphometric study on high-strength hydoxyapatite/poly(l-lactide) composite rods for internal fixation of bone fractures10.1002/(SICI)1097-4636(20000605)50:3<410::AID-JBM16>3.0.CO;2-Y ↗
28. MR Imaging of biodegradable polylevolactide osteosynthesis devices in the ankle10.1097/00005131-199711000-00003 ↗
29. Biodegradation and strength retention of poly-l-lactide screws in vivo. an experimental long-term study in sheep
30. Composite resorbable polymer/hydroxylapatite composite screws for fixation of osteochondral osteotomies